CS Paper Radar

Virtual iEEG from Scalp EEG: Charting the Landscape of Source Imaging, Intracranial Inference and Reconstruction

Dongyi He, Xiangkai Wang, Hongjie Yan, Luping Song, Wai Ting Siok, Nizhuan Wang

cs.CV ·submitted 2026-08-27 11:44 UTC · v1

Abstract

Intracranial electroencephalography (iEEG) provides temporally precise and spatially specific access to neural activity from focal and deep brain regions, but its invasiveness and restricted anatomical coverage limit routine use. These constraints have motivated scalp-to-intracranial inference, termed virtual iEEG when model outputs carry iEEG-defined event, feature, representation, or contact-level waveform semantics. This review presents a target-centred framework distinguishing event inference, feature translation, and waveform reconstruction, while separating predictability from observability, identifiability, fidelity, and utility. Evidence is evaluated according to cohort independence, anatomical and spectral coverage, train--test separation, and target-patient adaptation. Current studies support inference of selected intracranial events, low-frequency components, and task-related representations, but not unique recovery of arbitrary contact-level activity. Stronger validation requires appropriate controls, source-imaging baselines, uncertainty assessment, and incremental-utility testing. Future progress depends on independent paired datasets and prospective evidence that virtual iEEG adds value beyond scalp EEG and EEG source imaging.

Closest papers

Nearest neighbours by meaning across the whole index.

iEEG Can Help EEG: Improving Clinical Scalp EEG Analysis through Intracranial Priors

cs.LG eess.SPq-bio.NC ·2026-11-16 ·Xianglong Bao, Yi Ding, Zengxiang Li, Nan Liu, Kewen Wang +2 more
top venuecode/data similarity 0.70
Abstract · Accepted at KDD 2027

Scalp electroencephalography (EEG) is a cornerstone of clinical brain monitoring, making the quality of its signal fundamental to downstream tasks and models. However, that signal is heavily contaminated by non-neural interference and blurred by volume conduction. Existing methods operate almost exclusively within the scalp modality, so they inherit the contamination they would need to overcome. In practice, intracranial EEG (iEEG) observes the neural activity with far higher fidelity, yet it is invasive and therefore scarce, and the two modalities are rarely recorded as pairs at scale, share no common channel space, and offer no clean ground truth to directly supervise a mapping. Motivated by the neuronal synchronization mechanism shared by the two modalities, we propose a reprogramming approach that fits a signal-to-signal model on iEEG alone and freezes it as a cross-modal prior. We introduce ReBrain, a framework to transfer an iEEG-learned prior to scalp EEG, which re-expresses any scalp signal through that prior and can be inserted upstream of any downstream model with no pairing or fine-tuning. ReBrain consistently improves host models across recordings from multiple hospitals and across architecture families, and our analysis traces this gain to genuine neural structure carried by iEEG rather than to the architecture itself. This work provides evidence that a scarce clean modality can serve as a transferable prior for an abundant noisy one, offering a general recipe for cross-modal transfer among biosignals. Our code is available at https://github.com/Xianglong-Bao/ReBrain.

0.62

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.70
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

iMINDBench: iEEG Multi-Institution Neural Decoding Benchmark

cs.LG ·2026-09-16 ·Geeling Chau, Saba Hashemi, Yonghyeon Gwon, Eshani Patel, Jan DeWitt +7 more
benchmark similarity 0.66
Abstract · 26 pages, 13 figures

Intracranial electroencephalography (iEEG) is widely used to record electrical activity directly from electrodes inside the human brain, making it an attractive modality for neural decoding. However, progress in iEEG decoding, especially toward general-purpose foundation models, remains difficult to measure reliably: datasets are task- or institution-specific, limiting evidence of generalization across tasks and recording environments, and preprocessing choices can strongly influence performance, making model improvements difficult to distinguish from preprocessing gains. Thus, we introduce iMINDBench, an iEEG Multi-Institution Neural Decoding Benchmark that evaluates models on a shared suite of fifteen decoding tasks across three naturalistic movie-watching datasets. The benchmark additionally defines standardized preprocessing tracks and fixed evaluation splits to support consistent model comparisons. Using iMINDBench, we find that the evaluated pretrained systems generally outperform baselines within their respective preprocessing tracks, while strong spectral baselines remain competitive across institutional datasets. In our scaling study, adding up to 25 times more supervised data from other subjects or institutions yields only small or task-dependent gains over within-session training. Together, these findings highlight the need for iEEG models that improve on strong preprocessing baselines and make more effective use of data across subjects and institutions. Project website: https://imindbench.github.io/

0.28

EEGBind: Detecting Source-Level Interictal Epileptiform Discharges via EEG-Centric Multimodal Binding

cs.LG cs.MMq-bio.NC ·2026-09-09 ·Muchen Li, Anglin Liu, Xuetian Gao, Ruijian Xu, Jintai Chen
top venuebenchmarkcode/data similarity 0.66
Abstract · 7 pages, 5 figures. Accepted to the 34th ACM International Conference on Multimedia (MM '26)

Source-level analysis of interictal epileptiform discharges (IEDs) is relevant to presurgical evaluation and treatment planning because it helps characterize where epileptiform activity is likely to arise. Beyond detecting whether an IED is present, this setting requires assigning IED-positive activity to clinically meaningful brain-region categories. This setting is challenging because source-region evidence in short electroencephalography (EEG) windows can be subtle, partial, and affected by subject variability, class imbalance, and imperfect multimodal context. We present EEGBind, an EEG-centric multimodal binding framework for five-class source-level IED classification. EEGBind treats EEG as the primary modality and binds synchronized video-context features around an EEG-centric representation. Instead of relying on early or overly strong multimodal fusion, which may perturb the source-sensitive EEG representation, EEGBind uses video context as auxiliary evidence for robust classification. A view-consistent repair stage is further used to improve hidden-set robustness while preserving the learned source-class boundary. On the NeuroMM 2026 Grand Challenge Track 3 NMM-Source-IED benchmark, EEGBind achieves 0.8395 on weighted-F1 and outperforms strong competitors. These results support EEG-centric multimodal binding as a practical strategy for source-level IED classification. The open-source code is available at https://github.com/HKUSTGZ-ML4Health-Lab/NeuroMM2026_IED_Detection.

0.55

PHASE: A Physiology-Guided Hierarchical Foundation Model for Intracranial EEG

cs.LG cs.AI ·2026-09-28 ·Yipeng Zhang, Chenda Duan, Yuanyi Ding, Tianyi Wang, Atsuro Daida +8 more
benchmark similarity 0.65
Abstract · Author Metadata Correction

Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristics, which carry much of the information that downstream tasks depend on. Recent iEEG foundation models learn by reconstructing or predicting their inputs, which leaves the retention of these characteristics implicit. They are also evaluated mainly on cognitive decoding and a narrow clinical task, i.e., seizure detection. On a broad, clinically relevant benchmark such as Omni-iEEG, they remain below task-specific models when used frozen. We introduce PHASE, a physiology-guided foundation model that makes these characteristics explicit learning targets, pairing them with masked latent prediction in a temporal stage (PHASE-T) within each channel and a spatiotemporal stage (PHASE-ST) across synchronized channels. PHASE is pretrained on heterogeneous recordings from 222 participants at nine clinical sites. On all five Omni-iEEG clinical tasks, frozen PHASE-T outperforms every evaluated foundation model by up to 31\%, and fine-tuned PHASE-T surpasses the task-specific models, setting a new state of the art. PHASE-T benefits from physiological supervision, outperforming variants trained with latent prediction alone or auxiliary waveform reconstruction on every task in matched ablations. PHASE-T generalizes to unseen institutions, outperforming the compared models with few or no local labels. PHASE-ST further improves seizure-onset-zone identification over PHASE-T and, when frozen, decodes sound volume and pitch on BrainTreebank better than published models. Beyond task performance, PHASE learns to encapsulate the physiological characteristics clinicians recognize, from seizure onset and its propagation to anatomical region identity, even though its pretraining contains no ictal recordings or anatomical labels.

0.08

Parameter-Efficient Self-Supervised Adaptation for EEG-FM under Fixed Computational Budgets

cs.LG cs.AI ·2026-08-25 ·Meghal Dani, Stefanie Liebe
top venuecode/data similarity 0.65
Abstract

EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tuning is impractical for resource-constrained clinical settings due to high computational requirements. In this work, we investigate whether parameter-efficient self-supervised adaptation, updating only 9% of parameters suffices to align representations to target tasks. We evaluate our method on two state-of-the-art models with different pretraining objectives: BIOT (contrastive) and CBraMod (masked reconstruction), and evaluate on three clinical EEG datasets for abnormality detection (TUAB), event classification (TUEV), and seizure detection (CHB-MIT) under both in-distribution and out-of-distribution conditions. SSL adaptation yields consistent gains over linear probing, up to 20x AUCPR. Under a fixed compute budget, peak performance requires only 20--50% of available unlabeled data. Critically, when total window count is fixed, performance remains invariant to patient count, suggesting that performance is dependent on overall temporal window diversity only. Our findings demonstrate that parameter-efficient adaptation enables effective deployment of EEG Foundation models (EEG-FM) with minimal computational overhead and data collection burden. Code available at: https://github.com/c3n-group/efficient-eeg-adapt

0.54

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.65
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.65
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.27