CS Paper Radar

Parameter-Efficient Self-Supervised Adaptation for EEG-FM under Fixed Computational Budgets

Meghal Dani, Stefanie Liebe

cs.LG cs.AI ·submitted 2026-08-25 15:38 UTC · v1
top venuecode/data

Abstract

EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tuning is impractical for resource-constrained clinical settings due to high computational requirements. In this work, we investigate whether parameter-efficient self-supervised adaptation, updating only 9% of parameters suffices to align representations to target tasks. We evaluate our method on two state-of-the-art models with different pretraining objectives: BIOT (contrastive) and CBraMod (masked reconstruction), and evaluate on three clinical EEG datasets for abnormality detection (TUAB), event classification (TUEV), and seizure detection (CHB-MIT) under both in-distribution and out-of-distribution conditions. SSL adaptation yields consistent gains over linear probing, up to 20x AUCPR. Under a fixed compute budget, peak performance requires only 20--50% of available unlabeled data. Critically, when total window count is fixed, performance remains invariant to patient count, suggesting that performance is dependent on overall temporal window diversity only. Our findings demonstrate that parameter-efficient adaptation enables effective deployment of EEG Foundation models (EEG-FM) with minimal computational overhead and data collection burden. Code available at: https://github.com/c3n-group/efficient-eeg-adapt

Closest papers

Nearest neighbours by meaning across the whole index.

Lightweight Semantic EEG Foundation Model for Frozen Cross-Disorder Transfer

cs.LG eess.SPq-bio.NC ·2026-10-04 ·Rita Huan-Ting Peng, Nhat Bui
similarity 0.76
Abstract

Large-scale EEG foundation models have demonstrated promising transferability across neurological disorders, but often require millions of parameters and substantial computational resources. In this paper, we present the Universal Semantic EEG Foundation Model (USE-FM), a lightweight EEG foundation model that learns transferable neural representations through self-supervised signal reconstruction on the Temple University Hospital EEG Corpus (TUEG). After pretraining, the encoder is frozen and evaluated on two clinically distinct downstream tasks, abnormal EEG detection (TUAB) and epileptic seizure recognition (TUEP), using a unified frozen-transfer protocol against recent EEG foundation models, including LUNA-Base and CBraMod. With only 1.46 million parameters, approximately one-fifth the size of existing models, USE-FM achieves competitive overall performance, including strong sensitivity and F1-score on TUEP (SEN $75.00 \pm 14.14$, F1 $70.37 \pm 4.01$), while maintaining competitive performance on TUAB (AUC $85.24 \pm 5.61$). Beyond downstream classification, latent representation analysis using $k$-means clustering together with PCA and t-SNE demonstrates that USE-FM learns organized semantic EEG representations comparable to substantially larger foundation models. These results suggest that large-scale self-supervised pretraining enables lightweight architectures to learn transferable semantic EEG representations, providing a computationally efficient foundation for cross-disorder analysis and future clinical decision support in neurological disorders.

0.06

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

cs.HC cs.LGeess.SP ·2026-09-10 ·Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
similarity 0.73
Abstract · 11 pages, 7 figures 8 tables, journal submission

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000$\times$ more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0$\times$ lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.

0.43

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.72
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.71
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.69
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

cs.LG cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
position similarity 0.69
Abstract · Preprint. Under review

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.

0.21

SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series

cs.LG ·2026-11-13 ·Hannes Ill, Dimitrios Proios, Leo Anthony Celi, Peter J. Schüffler
top venuebenchmarkcode/datahot direction similarity 0.68
Abstract · Accepted at the Machine Learning for Health (ML4H) Symposium 2026, Proceedings track (PMLR 346). 28 pages, 8 figures, 21 tables. v2: author …

Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.

0.59

EEG-PRIME: Prototype-Aligned Representation Learning with Multi-Level Conditioning for EEG Decoding

cs.AI ·2026-08-13 ·Shuailei Zhang, Muyun Jiang, Wei Zhang, Jinbo Chen, Zhiwei Guo +3 more
similarity 0.68
Abstract

Electroencephalography (EEG) decoding models often generalize poorly across datasets and subjects due to domain shifts in acquisition protocols and individual neurophysiology. We propose EEG-PRIME, a two-stage EEG foundation model for cross-dataset multi-task decoding. EEG-PRIME combines masked pretraining with prototype-aligned instruction tuning to enable instruction-aware and subject-invariant decoding across diverse BCI paradigms. During pretraining, an EEG encoder learns transferable representations through masked reconstruction with frequency-cutoff spectral augmentation. During instruction tuning, EEG-PRIME incorporates task-semantic, dataset-specific, and subject-invariant conditioning. The resulting conditioning signal modulates the Q-Former through Layer-wise Query Modulation, while frozen text embeddings of class labels serve as prototypes for cosine-similarity-based prediction across heterogeneous label spaces. Experiments on sixteen datasets covering motor imagery, emotion recognition, ADHD detection, covert speech, and mental workload show consistent improvements over state-of-the-art baselines and prior EEG foundation models under cross-subject settings. On two additional held-out datasets, EEG-PRIME achieves balanced accuracy comparable to within-session calibration models without target-domain optimization, calibration, or linear probing, demonstrating promising zero-shot transfer capability.

0.04