CS Paper Radar

SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series

Hannes Ill, Dimitrios Proios, Leo Anthony Celi, Peter J. Schüffler

cs.LG ·submitted 2026-11-13 19:16 UTC · v2
top venuebenchmarkcode/datahot direction

Abstract

Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.

Comment
Accepted at the Machine Learning for Health (ML4H) Symposium 2026, Proceedings track (PMLR 346). 28 pages, 8 figures, 21 tables. v2: author block reformatted per ML4H format check; minor text edits to keep the page limit. Code: https://github.com/hannesill/SLICES/tree/ml4h-2026

Closest papers

Nearest neighbours by meaning across the whole index.

GARLIC: Graph Attention-based Relational Learning of Multivariate Time Series in Intensive Care

cs.LG ·2026-08-11 ·Ruirui Wang, Yanke Li, Manuel Günther, Diego Paez-Granados
top venue similarity 0.69
Abstract · *Equal contribution

Healthcare data, such as Intensive Care Unit (ICU) records, comprise heterogeneous multivariate time series sampled at irregular intervals with pervasive missingness. However, clinical applications demand predictive models that are both accurate and interpretable. We present our Graph Attention-based Relational Learning for Intensive Care (GARLIC) model, a novel neural network architecture that imputes missing data through a learnable exponential-decay encoder, captures inter-sensor dependencies via time-lagged summary graphs, and fuses global patterns with cross-dimensional sequential attention. All attention weights and graph edges are learned end-to-end to serve as built-in observation-, signal-, and edge-level explanations. To reconcile auxiliary reconstruction and primary classification objectives, we developed an alternating decoupled optimization scheme that stabilizes training. On three ICU benchmarks (PhysioNet 2012 & 2019, MIMIC-III), GARLIC sets the new state of the art in outcome prediction, significantly improving AUROC and AUPRC over best-performing baselines at comparable computational cost. Ablation studies confirm the contribution of each module, and feature-removal trials validate the fidelity of importance attribution through a monotonic performance drop (full > top 50% > random 50% > bottom 50%). Real-time case studies demonstrate actionable risk warnings with transparent explanations, marking a significant advance toward accurate, explainable deep learning for irregularly sampled ICU time series data. Moreover, we demonstrated \proposed{}'s superiority in data imputation and classification on various time-series datasets beyond the ICU domain, showing its generalizability and applicability to broader tasks.

0.72

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.69
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

Parameter-Efficient Self-Supervised Adaptation for EEG-FM under Fixed Computational Budgets

cs.LG cs.AI ·2026-08-25 ·Meghal Dani, Stefanie Liebe
top venuecode/data similarity 0.68
Abstract

EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tuning is impractical for resource-constrained clinical settings due to high computational requirements. In this work, we investigate whether parameter-efficient self-supervised adaptation, updating only 9% of parameters suffices to align representations to target tasks. We evaluate our method on two state-of-the-art models with different pretraining objectives: BIOT (contrastive) and CBraMod (masked reconstruction), and evaluate on three clinical EEG datasets for abnormality detection (TUAB), event classification (TUEV), and seizure detection (CHB-MIT) under both in-distribution and out-of-distribution conditions. SSL adaptation yields consistent gains over linear probing, up to 20x AUCPR. Under a fixed compute budget, peak performance requires only 20--50% of available unlabeled data. Critically, when total window count is fixed, performance remains invariant to patient count, suggesting that performance is dependent on overall temporal window diversity only. Our findings demonstrate that parameter-efficient adaptation enables effective deployment of EEG Foundation models (EEG-FM) with minimal computational overhead and data collection burden. Code available at: https://github.com/c3n-group/efficient-eeg-adapt

0.54

Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models

cs.LG ·2026-11-02 ·Muhan Yeo, Bong Gyun Kang, HyunGi Kim, Sungroh Yoon
top venue similarity 0.68
Abstract · Accepted at NeurIPS 2026

Deep learning models for electronic health records achieve strong predictive performance but provide little insight into what clinical concepts they represent internally. Post-hoc attribution methods produce per-cell importance scores that lack temporal coherence, cross-variable structure, and reusability across patients. We introduce the Temporal Island Sparse Autoencoder (TI-SAE), which learns a backbone-specific, patient-shared clinical concept dictionary from a frozen predictive model's representations. Each dictionary entry (latent) is defined by learned temporal Gaussian islands (specifying when the concept is active) and a sparse variable-composition vector (specifying which variables are involved). A decoupled selector then identifies which dictionary entries drive each patient's prediction, separating representation learning from attribution. We evaluate TI-SAE across five backbone architectures spanning different representation strategies on MIMIC-III and MIMIC-IV (three prediction tasks each). TI-SAE produces structured clinical concepts that go beyond transient attribution heatmaps while achieving strong performance on standard faithfulness benchmarks.

0.31

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.67
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

L2GSSL: Label-Efficient Local-to-Global Self-Supervised Learning for Volumetric Healthcare Data

cs.CV cs.LG ·2026-10-15 ·Po-Cheng Cheng, Hung-Hsuan Chen
similarity 0.66
Abstract · 10 pages, 2 figures, 10 tables. Under review at IEEE BigData 2026

Healthcare institutions routinely accumulate high-dimensional computed tomography (CT) volumes, but only a fraction can be annotated by experts. We present L2GSSL, a local-to-global self-supervised learning framework that leverages unlabeled volumes by decomposing pretraining into intra-slice and inter-slice representation spaces. A slice encoder learns view-invariant local features, and a global encoder aggregates the resulting tokens to model volumetric context. The stop-gradient isolates the local space from the global objective, while slice-wise execution and a three-phase schedule support training under constrained GPU memory. On LIDC-IDRI lung nodule malignancy classification, L2GSSL reaches $0.9229$ AUROC with only $10\%$ of the labels and $0.9377$ with $25\%$, exceeding the volume-level VICReg by $0.0229$ and $0.0294$, respectively. With all labels, the strongest supervised baseline exceeds L2GSSL by only $0.0044$ AUROC, consistent with self-supervised pretraining providing its greatest value when annotations are limited. Without adaptation to the external LNDb cohort, a model fine-tuned on $25\%$ of LIDC-IDRI obtains $0.8138$ AUROC and $0.7589$ AUPRC, improving over the strongest evaluated self-supervised baseline by $0.1130$ and $0.0954$. Experiments across data sources, thoracic and abdominal anatomy, downstream tasks, and two backbones examine healthcare-data variety, while lesion-slice masking shows that the predictions depend on lesion-bearing content.

0.27

Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label Regimes

cs.CV cs.LG ·2026-11-04 ·Alicem Koyun, Pranjali Changadeo Pingale, Sachin Mote, Gianluca Pizzuti
publishedbenchmarkcode/data similarity 0.66
Abstract · Oral presentation, CIBB 2026 (21st International Conference on Computational Intelligence Methods for Bioinformatics and Biostatistics, Rome…

Expert annotation in digital pathology is expensive, and low-label regimes remain common in realistic histopathology workflows. Self-supervised learning (SSL) offers a practical way to learn transferable representations from unlabeled pathology images, but performance-only evaluation can hide unreliable confidence behavior under domain shift. We present a reliability-aware benchmark of SimCLR, BYOL, and an MAE-inspired masked-reconstruction baseline on PatchCamelyon (PCam; 96x96) and PANDA (prostate cancer) under 1%, 5%, and 10% labeled regimes with frozen-encoder linear probing. To address common single-run concerns, ResNet-18 results are repeated over 3 splits x 3 seeds (n=9) and ViT-B/16 over 1 split x 3 seeds (n=3) under practical compute constraints, with mean+/-std reporting and per-run logs. Beyond AUROC, accuracy, and F1-score, we report Expected Calibration Error and Brier score, OOD confidence diagnostics for cross-dataset PCam<->PANDA scoring, federated-vs-centralized SimCLR comparisons on PCam, and cross-dataset transfer to colorectal histology tiles. SSL improves label efficiency on the more controlled PCam task, while PANDA's noisier patch-level proxy can remain near coin-flip with higher variance. The study highlights that histopathology SSL should be assessed not only by ranking performance but also by calibration, robustness, and transparent reproducibility diagnostics before clinical interpretation.

0.46

Are Joint-Embedding Predictive Objectives Effective for Longitudinal EHRs?

cs.LG cs.AI ·2026-10-21 ·Ashvin Gupta, Brendan Delaney, Alessandra Russo
similarity 0.65
Abstract

Masked language modelling (MLM) is the dominant pretraining objective for transformer encoders applied to longitudinal electronic health records (EHRs). However, reconstructing individual events may overemphasise noisy or weakly informative observations and does not explicitly encourage learning higher-level patient states. Joint-Embedding Predictive Architectures (JEPAs) instead learn by predicting representations in latent space and have shown strong performance in a variety of domains. In this paper, we investigate to what extent JEPA can be adapted to EHR sequence representation. Our empirical investigation using MIMIC-IV shows that although all three of our JEPA formulations train stably without representational collapse, they consistently underperform standard MLM. We find that target size, not target heterogeneity, increases prediction error, yet reducing the target size does not recover downstream performance. This suggests that stable latent prediction alone is insufficient for competitive EHR representation learning and highlights the challenge of defining clinically meaningful latent targets for EHR.

0.06