CS Paper Radar

Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label Regimes

Alicem Koyun, Pranjali Changadeo Pingale, Sachin Mote, Gianluca Pizzuti

cs.CV cs.LG ·submitted 2026-11-04 03:59 UTC · v1
publishedbenchmarkcode/data

Abstract

Expert annotation in digital pathology is expensive, and low-label regimes remain common in realistic histopathology workflows. Self-supervised learning (SSL) offers a practical way to learn transferable representations from unlabeled pathology images, but performance-only evaluation can hide unreliable confidence behavior under domain shift. We present a reliability-aware benchmark of SimCLR, BYOL, and an MAE-inspired masked-reconstruction baseline on PatchCamelyon (PCam; 96x96) and PANDA (prostate cancer) under 1%, 5%, and 10% labeled regimes with frozen-encoder linear probing. To address common single-run concerns, ResNet-18 results are repeated over 3 splits x 3 seeds (n=9) and ViT-B/16 over 1 split x 3 seeds (n=3) under practical compute constraints, with mean+/-std reporting and per-run logs. Beyond AUROC, accuracy, and F1-score, we report Expected Calibration Error and Brier score, OOD confidence diagnostics for cross-dataset PCam<->PANDA scoring, federated-vs-centralized SimCLR comparisons on PCam, and cross-dataset transfer to colorectal histology tiles. SSL improves label efficiency on the more controlled PCam task, while PANDA's noisier patch-level proxy can remain near coin-flip with higher variance. The study highlights that histopathology SSL should be assessed not only by ranking performance but also by calibration, robustness, and transparent reproducibility diagnostics before clinical interpretation.

Comment
Oral presentation, CIBB 2026 (21st International Conference on Computational Intelligence Methods for Bioinformatics and Biostatistics, Rome, Italy). 6 pages, 4 figures, 3 tables. Code: https://github.com/alicemkyn/ssl-histopath-reliability

Closest papers

Nearest neighbours by meaning across the whole index.

Training-Time Domain Transfer for Generator-Free Diagnostics on Novel Modalities in Computational Pathology

cs.CV cs.AI ·2026-11-02 ·Julia A. Mielcarz, Andrea Camilloni, Nita Mulliqi, Jessica A. Frank, Anders Blilie +3 more
benchmark similarity 0.69
Abstract · 4 pages, 2 figures. Submitted to IEEE ISBI 2027

Novel imaging modalities promise improved diagnostics, but AI development is constrained by scarce training data. Inference-time domain transfer can address this by mapping novel modalities to established ones, enabling reuse of existing diagnostic models. However, this introduces hallucination risks, computational overhead, and regulatory complexity. Inspired by sim-to-real transfer, we propose training-time domain transfer, generating synthetic target-domain training data from archived routine samples to enable direct diagnosis on real inputs without inference-time generation. Using unstained prostate histopathology as a proof-of-concept, we compare this approach with inference-time virtual staining and conventional H&E-based cancer detection. Training-time transfer achieved higher concordance with the conventional benchmark than virtual staining for both raw (Cohen's $κ$=0.59 vs. 0.37; Gwet's AC1=0.73 vs. 0.29) and deparaffinized tissue ($κ$=0.66 vs. 0.61; AC1=0.73 vs. 0.64), supporting its potential for emerging diagnostic modalities.

0.29

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.68
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Label-Free Coreset Selection with Foundation Models for Efficient Annotation in Computational Pathology

cs.CV ·2026-10-05 ·Tuo Yin, Jennifer Dhont
code/data similarity 0.67
Abstract · 32 pages, 7 figures

Computational pathology has the potential to improve clinical outcomes through a demonstrated increase in diagnostic and prognostic accuracy. However, the development and validation of deep learning algorithms still require annotated data, a costly procedure involving expert pathologists who already face critical workforce shortages. Existing coreset selection methods to optimize annotation efforts currently all rely on hyperparameters tuned on natural-image benchmarks that do not transfer to histopathology and are cumbersome to use in clinical practice. In this study, we present GCcore, a novel label-free coreset selection method that embeds every image of a dataset with any pathology foundation model and greedily selects the samples that collectively maximize the global coverage of the embedding space. The proposed method provides a lower-bound guarantee on the global coverage of the returned coreset for any coreset size, while being completely hyperparameter-free and deterministic. We demonstrate GCcore's superior performance over 14 baselines including state-of-the-art methods across 10 tasks and datasets spanning whole slide image classification, tile classification, and tissue segmentation, where it ranks first on six and within the top three on nine, while also demonstrating how existing methods can shift by up to five rank positions depending on their hyperparameter settings. Code is publicly available at https://github.com/OncoAI-ULBHUB/GCcore.

0.23

SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series

cs.LG ·2026-11-13 ·Hannes Ill, Dimitrios Proios, Leo Anthony Celi, Peter J. Schüffler
top venuebenchmarkcode/datahot direction similarity 0.66
Abstract · Accepted at the Machine Learning for Health (ML4H) Symposium 2026, Proceedings track (PMLR 346). 28 pages, 8 figures, 21 tables. v2: author …

Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.

0.59

L2GSSL: Label-Efficient Local-to-Global Self-Supervised Learning for Volumetric Healthcare Data

cs.CV cs.LG ·2026-10-15 ·Po-Cheng Cheng, Hung-Hsuan Chen
similarity 0.66
Abstract · 10 pages, 2 figures, 10 tables. Under review at IEEE BigData 2026

Healthcare institutions routinely accumulate high-dimensional computed tomography (CT) volumes, but only a fraction can be annotated by experts. We present L2GSSL, a local-to-global self-supervised learning framework that leverages unlabeled volumes by decomposing pretraining into intra-slice and inter-slice representation spaces. A slice encoder learns view-invariant local features, and a global encoder aggregates the resulting tokens to model volumetric context. The stop-gradient isolates the local space from the global objective, while slice-wise execution and a three-phase schedule support training under constrained GPU memory. On LIDC-IDRI lung nodule malignancy classification, L2GSSL reaches $0.9229$ AUROC with only $10\%$ of the labels and $0.9377$ with $25\%$, exceeding the volume-level VICReg by $0.0229$ and $0.0294$, respectively. With all labels, the strongest supervised baseline exceeds L2GSSL by only $0.0044$ AUROC, consistent with self-supervised pretraining providing its greatest value when annotations are limited. Without adaptation to the external LNDb cohort, a model fine-tuned on $25\%$ of LIDC-IDRI obtains $0.8138$ AUROC and $0.7589$ AUPRC, improving over the strongest evaluated self-supervised baseline by $0.1130$ and $0.0954$. Experiments across data sources, thoracic and abdominal anatomy, downstream tasks, and two backbones examine healthcare-data variety, while lesion-slice masking shows that the predictions depend on lesion-bearing content.

0.27

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

eess.IV cs.AIcs.CV ·2026-08-22 ·Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
benchmark similarity 0.65
Abstract · 10 pages, 7 figures. Submitted to WACV 2027

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

0.33

When Do Histology Foundation Models Need Geometric Test-Time Augmentation?

cs.CV cs.LG ·2026-11-16 ·Lars Chen, Valentino F. Foit, Dorry Segev, Michal Mankowski
benchmarkcode/data similarity 0.64
Abstract · 17 pages, 5 figures

Test-time augmentation (TTA) aggregates model predictions across multiple transformed views of an input during inference. Because histology images lack a canonical orientation, $D_4$ TTA---pooling across the 8 rotations and reflections of a square---is a standard default in computational pathology. However, the rise of self-supervised histology foundation models (FMs) with inherent rotational invariance calls its continued utility into question. We benchmark 9 histology FMs and 6 general-purpose models across four patch-level and two whole-slide image (WSI) datasets. We find that $D_4$ TTA remains a reliable post hoc improvement, but benefits diminish from $+1.98$ percentage points (pp) for general-purpose backbones to $+0.50$ pp for histology FMs on TCGA-UT, and shrink further for the largest models. To eliminate computational overhead, our experiments demonstrate that entropy routing---applying TTA selectively to uncertain predictions---recovers most of the gain while augmenting only ${\sim}13\%$ of samples. Finally, we show that patch-level TTA improvements do not transfer to slide-level multiple instance learning (MIL). Code: https://github.com/lars-chen/histology-tta

0.43

MUST-PET: MUltimodal Self-supervised learning across Tracers for whole-body PET/CT-based lesion segmentation

cs.CV ·2026-08-20 ·Bashirul Azam Biswas, Amartya Bhattacharya, Biratal Raj Wagle, Matthew E. Maeder, James B. Yu +1 more
similarity 0.64
Abstract · Submitted to SPIE CAD 2027

Deep learning-based whole-body PET-CT lesion segmentation can support cancer staging, treatment planning, and response assessment, but generalization is limited by scarce annotations and domain shifts. Self-supervised learning (SSL) can address these challenges but remains underexplored in pan-cancer, multi-tracer PET-CT. In this work, we propose MUST-PET (MUltimodal Self-Supervised learning across Tracers), a multimodal, multi-tracer SSL framework for generalizable whole-body PET-CT lesion segmentation. MUST-PET is trained and validated on a diverse, multi-institutional collection of pan-cancer PET-CT scans acquired with FDG and prostate-specific membrane antigen (PSMA)-targeted radiotracers. MUST-PET uses context-aware masked reconstruction, where one modality is partially masked and reconstructed using complementary information from both PET and CT. The pretrained model is subsequently fine-tuned with labeled samples and evaluated for reconstruction quality, lesion segmentation, label efficiency, and generalizability across independent held-out datasets. MUST-PET reduces reconstruction error, improves lesion segmentation over training from scratch, and performs well with limited labeled data and on unseen external datasets, demonstrating the potential of multi-tracer SSL for label-efficient, generalizable whole-body PET-CT. segmentation.

0.40