CS Paper Radar

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen

eess.IV cs.AIcs.CV ·submitted 2026-08-22 17:57 UTC · v1
benchmark

Abstract

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

Comment
10 pages, 7 figures. Submitted to WACV 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.68
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.66
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Adaptive Conformal Redistribution for Inter-class Transitional Uncertainty in Medical Image Classification

cs.CV cs.AIcs.LGstat.CO+1 ·2026-09-10 ·Saibal Ghosh, Samarup Bhattacharya, Sanjoy Kumar Saha, Umapada Pal, Tapabrata Chakraborti
benchmarkcode/data similarity 0.66
Abstract

Medical image classification is frequently complicated by transitional categories whose feature distributions overlap those of adjacent classes, producing ambiguous decision boundaries. Conformal prediction returns uncertainty-aware prediction sets, but these are not directly actionable in clinical screening, where a single decision is required. This work proposes adaptive conformal redistribution (AdaConRed), a label-free post-conformal decision rule that converts ambiguous prediction sets into refined class assignments. A five-stage pipeline is developed. Vision-language generative augmentation addresses minority-class scarcity; a frozen DermFoundation encoder provides embeddings; a lightweight multi-layer perceptron performs classification; an entropy-modulated, margin-aware nonconformity score constructs adaptive prediction sets; samples predicted as transitional with multi-label sets are reassigned to the most probable alternative class within the set, using only model outputs at inference. Evaluation uses the OSCC oral lesion and ISIC skin lesion benchmarks at a miscoverage level of 0.2. On the 3-class OSCC benchmark, overall accuracy improves from 73.54% to 77.38%, with oral cancer accuracy rising from 64.29% to 82.14% and benign accuracy from 56.57% to 70.20%. Reassignment of transitional samples reduces OPMD accuracy from 84.78% to 80.16%, consistent with the asymmetric cost of missed malignancy. On ISIC, overall accuracy improves from 85.83% to 87.19%, melanoma accuracy rising from 66.04% to 68.34%. AdaConRed outperforms LAC, APS and RAPS under an identical backbone and redistribution rule. Conformal prediction can be extended beyond uncertainty quantification toward actionable decision support where transitional disease categories are present, with gains concentrated in the clinically critical malignant categories. Code repository: https://github.com/saibal436ghosh/AdaConRed.

0.38

Representation Risk in Pretrained Image Encoders

cs.CV econ.GN ·2026-09-28 ·Ardyn Nordstrom, Morgan Nordstrom, Vamuyan Sesay, Matthew D. Webb
benchmark similarity 0.66
Abstract

Applied researchers increasingly convert images into features with pretrained encoders, then use those features in a downstream prediction model. The encoder is often treated as an implementation detail. We show that it can instead be a consequential source of model uncertainty. We call this uncertainty representation risk: plausible pretrained encoders map the same images into different feature spaces and can yield sharply different out-of-sample conclusions from predictive performance. We compare ten modern and legacy frozen encoders across applications involving house prices, racehorse performance, breast-cancer histology, chest radiographs, continuous facial age, and rice disease. With common dimension control, heads, and group-safe splits, validation selects SigLIP 2 for houses, raising test $R^2$ from 0.396 for ResNet50 to 0.629, and DINOv2 for horses, raising $R^2$ from 0.029 to 0.105. No encoder is best in every task. Candidate procedures are constructed using training data and compared on a separate validation partition. The selected procedure reaches 0.658 for houses and 0.979 accuracy for pneumonia. Fixed-split gains are small for horses and rice, while repeated partitions reveal instability in horse feature union. Continuous age selects SigLIP 2 at 4.786 years MAE. The principal representation gaps persist with neural heads, similarly sized DINOv2 and ViT models, and limited adaptation. These results support a simple workflow: benchmark plausible representations, select on locked validation data, combine only when separate validation evidence justifies the additional cost, and report paired and split-level uncertainty. We implement this workflow in LOOKAGAIN-ML, the software package used to conduct the analyses in this paper.

0.31

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

cs.CV cs.AI ·2026-10-13 ·Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang +5 more
benchmark similarity 0.66
Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

0.20

How Far from Clinical Deployment? Evaluating the Complete Unsupervised Domain Adaptation Pipeline in Medical Imaging

cs.CV cs.AI ·2026-08-12 ·Yiheng Xiong, Luisa Gallée, Daniel Santak Wolf, Heiko Hillenhagen, Michael Götz
publishedcode/data similarity 0.65
Abstract · Accepted to WACV 2027

Deploying unsupervised domain adaptation (UDA) in clinical practice requires choosing which algorithm to use and which of its trained models to ship. However, the deployment (target) domain is unlabeled, so models cannot be evaluated directly on it, leaving it unclear which to select. We address this by evaluating the complete UDA pipeline, considering both adaptation and label-free selection together. Our study covers eleven clinically relevant cross-domain scenarios from nine medical imaging datasets, with ten UDA algorithms and 13 label-free selection methods (validators), evaluating over 80,000 trained models in total. By this, we find that a capable adapted model usually exists, but identifying it without target labels is difficult: the validator-selected models leave a large and structural target performance gap to the best available one, with no evaluated validator consistently reliable. Towards closing it, we explore two strategies, ensembling and a small target-labeling budget; both narrow this gap but do not close it entirely. Overall, deployable UDA depends on the complete pipeline; addressing the less explored selection step could bring much of current UDA closer to clinical use. Our code is open sourced at \href{https://xiongyiheng.github.io/complete-uda-pipeline-site/}{Project Page}.

0.80

Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label Regimes

cs.CV cs.LG ·2026-11-04 ·Alicem Koyun, Pranjali Changadeo Pingale, Sachin Mote, Gianluca Pizzuti
publishedbenchmarkcode/data similarity 0.65
Abstract · Oral presentation, CIBB 2026 (21st International Conference on Computational Intelligence Methods for Bioinformatics and Biostatistics, Rome…

Expert annotation in digital pathology is expensive, and low-label regimes remain common in realistic histopathology workflows. Self-supervised learning (SSL) offers a practical way to learn transferable representations from unlabeled pathology images, but performance-only evaluation can hide unreliable confidence behavior under domain shift. We present a reliability-aware benchmark of SimCLR, BYOL, and an MAE-inspired masked-reconstruction baseline on PatchCamelyon (PCam; 96x96) and PANDA (prostate cancer) under 1%, 5%, and 10% labeled regimes with frozen-encoder linear probing. To address common single-run concerns, ResNet-18 results are repeated over 3 splits x 3 seeds (n=9) and ViT-B/16 over 1 split x 3 seeds (n=3) under practical compute constraints, with mean+/-std reporting and per-run logs. Beyond AUROC, accuracy, and F1-score, we report Expected Calibration Error and Brier score, OOD confidence diagnostics for cross-dataset PCam<->PANDA scoring, federated-vs-centralized SimCLR comparisons on PCam, and cross-dataset transfer to colorectal histology tiles. SSL improves label efficiency on the more controlled PCam task, while PANDA's noisier patch-level proxy can remain near coin-flip with higher variance. The study highlights that histopathology SSL should be assessed not only by ranking performance but also by calibration, robustness, and transparent reproducibility diagnostics before clinical interpretation.

0.46

Prevalence calibration as shortcut mitigation

cs.LG cs.CV ·2026-09-07 ·Mohamed Amine Kina, Eike Petersen
published similarity 0.65
Abstract · Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction with MICCAI 2026. 11 pag…

Shortcut learning denotes the widespread situation in which a classifier exploits spurious correlations rather than diagnostic features. Existing mitigation strategies mostly aim to learn shortcut-invariant representations; their empirical success is limited and they cannot be applied to classifiers using frozen foundation model encoders. We propose to reframe shortcut learning as fundamentally a calibration problem: unconstrained learning implicitly calibrates each shortcut group to its training set disease prevalence, rendering the resulting classifier necessarily over-confident in one group and under-confident in the other. Building on this insight, we prevalence-equalize calibration between shortcut groups through two encoder-agnostic methods, an in-processing regularizer and a post-hoc prevalence-equalized recalibration step. Across chest-drain-pneumothorax benchmarks on CheXpert and SIIM-ACR, spanning fine-tuned CNNs and frozen foundation-model backbones, both methods substantially outperform all baselines. Post-hoc recalibration of a standard ERM-trained DenseNet raises misaligned-group AUROC from 0.23 to 0.73, indicating that shortcut reliance degrades the classification head rather than the underlying representation. Besides two new state-of-the-art shortcut mitigation approaches, our findings more fundamentally connect shortcut learning to calibration theory and algorithmic fairness.

0.45