CS Paper Radar

Prevalence calibration as shortcut mitigation

Mohamed Amine Kina, Eike Petersen

cs.LG cs.CV ·submitted 2026-09-07 19:38 UTC · v1
published

Abstract

Shortcut learning denotes the widespread situation in which a classifier exploits spurious correlations rather than diagnostic features. Existing mitigation strategies mostly aim to learn shortcut-invariant representations; their empirical success is limited and they cannot be applied to classifiers using frozen foundation model encoders. We propose to reframe shortcut learning as fundamentally a calibration problem: unconstrained learning implicitly calibrates each shortcut group to its training set disease prevalence, rendering the resulting classifier necessarily over-confident in one group and under-confident in the other. Building on this insight, we prevalence-equalize calibration between shortcut groups through two encoder-agnostic methods, an in-processing regularizer and a post-hoc prevalence-equalized recalibration step. Across chest-drain-pneumothorax benchmarks on CheXpert and SIIM-ACR, spanning fine-tuned CNNs and frozen foundation-model backbones, both methods substantially outperform all baselines. Post-hoc recalibration of a standard ERM-trained DenseNet raises misaligned-group AUROC from 0.23 to 0.73, indicating that shortcut reliance degrades the classification head rather than the underlying representation. Besides two new state-of-the-art shortcut mitigation approaches, our findings more fundamentally connect shortcut learning to calibration theory and algorithmic fairness.

Comment
Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction with MICCAI 2026. 11 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Look What the Probes Dragged In! Real-World Chest X-ray Shortcuts in MedCLIP

cs.CV cs.LG ·2026-08-12 ·Nikolette Pedersen, Regitze Sydendal, Veronika Cheplygina, Théo Sourget
publishedcode/data similarity 0.69
Abstract · 11 pages, 3 figure, poster presentation at the joint FAIMI, BRIDGE, and EPIMI workshop at MICCAI 2026 (Strasbourg, France) conference

Vision-language models, such as contrastive language-image pre-training (CLIP)-based approaches, have reached state-of-the-art (SOTA) results in medical artificial intelligence. However, recent work reveals that CLIP-based models remain vulnerable to shortcuts. We investigate how real-world shortcuts manifest across different layers of the medical CLIP-based model, MedCLIP, and its vision encoder, a frozen ResNet-50. We attach 17 linear classification probes to the intermediate layers of the ResNet-50 and train them on three different dataset configurations and targets: NIH-CXR14 (pneumothorax) and PadChest (cardiomegaly and pneumothorax). This setup allows us to observe model behaviour during evaluation using subgroup-based calibration and layer-wise confidence curves. We find that the final linear probes achieve a high AUROC but poor calibration in the models. The layer-wise confidence analyses suggest that shortcuts emerge at different depths. Patterns consistent with localised shortcuts, such as drains, appear at later layers, while patterns consistent with diffuse shortcuts, such as scanner-specific noise patterns, emerge earlier, aligning with previous work. Finally, we conduct a manual analysis of the images, which reveals data quality issues in both NIH-CXR14 and PadChest. Our findings underscore that even SOTA models remain vulnerable to shortcuts, and the need for high-quality and well-annotated datasets to draw solid conclusions. Code can be found on our GitHub: https://github.com/nikodice4/MedCLIP_shortcuts.

0.43

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

eess.IV cs.AIcs.CV ·2026-08-22 ·Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
benchmark similarity 0.65
Abstract · 10 pages, 7 figures. Submitted to WACV 2027

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

0.33

Representation Disentanglement for Fair Chest X-Ray Diagnosis

cs.CV cs.AI ·2026-10-05 ·Yujie Sun, Ruizhe Li, Xiaowu Sun
code/data similarity 0.65
Abstract · submit to ICASSP 2027

Deep learning has advanced chest X-ray (CXR) diagnosis, yet demographic biases in learned representations may contribute to performance disparities across intersectional groups. We propose a single-encoder framework combining dual-level decorrelation with prototype-guided cross-group contrastive learning to reduce demographic dependence while accounting for within-class variation. We further propose Demographic Representation Alignment Reduction (DRAR), a new metric that quantifies the reduction in demographic structure within disease representations. The framework is evaluated on four classification tasks using 34,809 CheXpert test images across eight intersectional groups, defined by age, sex and ethnicity. Compared with empirical risk minimization (ERM), our method reduces the mean equalized-odds gap from 15.41\% to 10.86\% and the AUC gap from 5.95\% to 5.01\%. Our method achieves a DRAR of 59.04\% relative to ERM, with only a slight decrease in mean AUC. These results demonstrate that representation disentanglement can reduce demographic bias and improve intersectional fairness. Code is available at \url{https://github.com/06Yujie/Fair-Medical-Imaging}.

0.25

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.63
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

MVC-Bench: Benchmarking Calibration of Medical Vision-Language Models

cs.CV ·2026-08-27 ·Ashshak Sharifdeen, Shihab Aaqil Ahamed, Ufaq Khan, Muhammad Akhtar Munir, Sujair Ibrahim +4 more
top venuebenchmark similarity 0.63
Abstract · Accepted in EMNLP 2026 Findings

Reliable evaluation of vision-language models (VLMs) and medical vision-language models (Medical-VLMs) requires calibrated confidence, particularly under realistic clinical conditions. However, existing efforts mainly focused on improving accuracy, leaving calibration in the medical domain underexplored. To this end, we propose MVC-Bench, a calibration-centric benchmark for medical image classification with VLMs and Medical-VLMs. MVC-Bench assesses the calibration across three axes: (i) robustness to modality, backbone, and domain shift (ii) effectiveness of calibration strategies and prompt-tuning methods (iii) stability under prompt-template and random-seed variations. The benchmark covers eight different backbones, three medical modalities, including fundus imaging, histopathology, and chest X-ray under in-domain and domain shift settings. It compares post-hoc calibration, train-time calibration, and zero-shot inference methods, together with six prompt-tuning methods. Across more than 1638 controlled experiments, we report accuracy and Expected Calibration Error (ECE) as primary metrics, and further report results with complementary calibration measures, including Maximum Calibration Error (MCE) and Adaptive Calibration Error (ACE). We further investigate the underlying causes of miscalibration in VLMs and Medical-VLMs and propose a simple train-time calibration method, Multi-Class Margin (MCM) regularization, which achieves lowest ECE on 10 out of 12 settings in in-domain and remains competitive under domain shifts. Collectively, MVC-Bench provides a structured evaluation framework and actionable guidance for improving calibration in safety-critical medical workflows.

0.58

Calibration-First Cross-Cohort Multimodal Temporal Learning for Transferable Asthma-Risk Forecasting

cs.LG cs.AI ·2026-09-17 ·Taimoor Ahmad
benchmark similarity 0.62
Abstract

Asthma deterioration forecasting must remain reli- able when patient populations, sensor ecosystems, and available modalities change across cohorts. Existing models commonly optimize within-cohort discrimination and may produce poorly calibrated probabilities after transfer. We present CALIBRA, a calibration-first multimodal temporal framework for short- horizon risk prediction with incomplete data. Dedicated recurrent encoders process environmental, pulmonary, symptom, medication, wearable, and context streams; a reliability-conditioned gate suppresses stale or absent modalities, while gradient-reversal training discourages avoidable cohort signatures. A shrinkage- based hierarchical logistic layer calibrates probabilities using a patient-disjoint target subset, and split conformal prediction provides abstention-capable prediction sets. To avoid fabricating clinical evidence, we evaluate the complete implementation on a documented three-cohort semi-synthetic benchmark with controlled distribution shift, informative missingness, and sealed target patients. Across five configured seeds, CALIBRA achieved mean target-test AUPRC 0.224 versus 0.240 for the strongest non-ablation comparator, TemporalTransformer; mean AUROC was 0.717, and Brier score was 0.098. Experiments additionally assess complete-modality failures, calibration, conformal coverage, decision curves, subgroup behavior, ablations, runtime, and parameter count. The results verify the method and reproducible pipeline under controlled shift, but do not establish clinical effectiveness. External validation on harmonized real asthma. Overall this artifact provides evidence for carefully governed real-cohort validation.

0.13

ConfTriage: A Calibration-Aware LLM Triage Framework for Pulmonary Nodule Malignancy with Selective Specialist Deferral

cs.CV ·2026-08-11 ·Md Rabiul Islam, Samir Abdaljalil, Erchin Serpedin, Hasan Kurban
theorycode/data similarity 0.62
Abstract · 14 pages, 8 figures. Currently under review

Pulmonary nodule malignancy prediction typically depends on image-trained specialist deep learning (DL) models that require substantial annotated imaging data and task-specific training. We investigate whether a generalist large language model (LLM), reading only a faithful natural-language rendering of standard nodule attributes, can serve as a calibrated triage layer. We propose ConfTriage, a confidence-calibrated method built on three pillars: language as the modality, calibration as the safety mechanism, and a selective specialist DL backstop for low-confidence cases. We prove two guarantees: a finite-sample combined-error bound yielding an explicit per-threshold operational certificate, and an oracle inequality showing that excess risk over the Bayes-optimal deferral classifier is controlled by the L1 calibration error of the LLM probability. A controlled seven-way input ablation across five frontier LLMs on LIDC-IDRI shows that natural-language descriptions dominate the diagnostic signal, while low-level image statistics are essentially diagnostically vacuous. ConfTriage achieved an F1 score of 88.22% and an AUC of 0.92, resolving 76.5% of cases using zero-shot LLM inference alone and referring only uncertain cases to the specialist DL backstop. These results demonstrate that clinically meaningful diagnostic information can be captured through structured radiological descriptions and leveraged by calibrated LLMs for selective referral. The framework suggests a practical pathway for combining generalist LLM prediction with specialist AI models in medical decision-support systems. Source code is publicly available at https://github.com/rabiul-ai/ConfTriage.

0.32

Impact of Data Augmentation on Confidence Calibration in Melanoma Classification

cs.AI cs.CVcs.LGcs.LO ·2026-10-05 ·Morgan May, Simon Caton, Pierpaolo Dondio
published similarity 0.62
Abstract · Presented at the 30th Conference on Medical Image Understanding and Analysis (MIUA 2026)

Accurately quantifying the predictive uncertainty or improving model calibration plays an important role in medical image classification, in particular in melanoma diagnosis, where accurate uncertainty quantification can have significant implications for patient care. One of the methods for calibration improvement is data augmentation. In addition, data augmentation as a method for synthetically increasing the size of the dataset has been proven to improve the performance of models trained on imbalanced datasets. However, the impact of data augmentation, as a transformation of a part of the original data, on calibration of models trained on imbalanced datasets, in particular in melanoma classification is under-explored. We train neural networks on SIIM-ISIC 2020 melanoma classification dataset under two conditions: with and without data augmentation, and compare the differences in AUC and expected calibration error (ECE) in both scenarios. Our results shows improvements in uncertainty calibration using different augmentation methods.

0.31