CS Paper Radar

Representation Disentanglement for Fair Chest X-Ray Diagnosis

Yujie Sun, Ruizhe Li, Xiaowu Sun

cs.CV cs.AI ·submitted 2026-10-05 09:40 UTC · v1
code/data

Abstract

Deep learning has advanced chest X-ray (CXR) diagnosis, yet demographic biases in learned representations may contribute to performance disparities across intersectional groups. We propose a single-encoder framework combining dual-level decorrelation with prototype-guided cross-group contrastive learning to reduce demographic dependence while accounting for within-class variation. We further propose Demographic Representation Alignment Reduction (DRAR), a new metric that quantifies the reduction in demographic structure within disease representations. The framework is evaluated on four classification tasks using 34,809 CheXpert test images across eight intersectional groups, defined by age, sex and ethnicity. Compared with empirical risk minimization (ERM), our method reduces the mean equalized-odds gap from 15.41\% to 10.86\% and the AUC gap from 5.95\% to 5.01\%. Our method achieves a DRAR of 59.04\% relative to ERM, with only a slight decrease in mean AUC. These results demonstrate that representation disentanglement can reduce demographic bias and improve intersectional fairness. Code is available at \url{https://github.com/06Yujie/Fair-Medical-Imaging}.

Comment
submit to ICASSP 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Subgroup performance analysis of adaptation strategies for chest X-ray foundation models

cs.CV ·2026-08-19 ·Dhruv Gupta, Emma A. M. Stanley, Fabio De Sousa Ribeiro, Sujal R. Desai, Ben Glocker
published similarity 0.74
Abstract · Accepted at MICCAI Workshop on Fairness of AI in Medical Imaging (FAIMI) 2026

Foundation models are increasingly adapted for downstream medical imaging tasks, yet the influence of the chosen adaptation strategy on subgroup fairness remains poorly understood. We investigate how three parameter-efficient adaptation techniques, including linear heads on the raw CLS token, an MLP, and an attention-pooling module over multi-layer patch features, affect both pathology classification performance and subgroup disparities when applied to the frozen Rad-DINO chest X-ray encoder. Using MIMIC-CXR, we evaluate eight pathologies across race, sex, and imaging-view subgroups on a prevalence-preserving, demographically balanced test set, and additionally probe how strongly each adapter encodes protected attributes. We find that attention pooling achieves the strongest overall discriminative performance and encodes attributes, particularly race, most strongly, but that improved overall performance does not consistently reduce subgroup disparities. Notably, stronger attribute encoding did not correspond to larger disparities: early network layers encoded race most weakly yet produced the largest subgroup performance gaps. Exploring different attention-pooling layer combinations further revealed no consistent relationship between the layers pooled, attribute encoding strength, and subgroup fairness. Our results indicate that richer, more expressive representations can improve accuracy while leaving fairness implications task-dependent and unpredictable, which must be assessed directly and per-task rather than inferred from encoding strength or overall performance alone.

0.38

Is invariance all you need for algorithmic fairness? Removing demographic information can create new bias

cs.LG cs.AI ·2026-09-25 ·Aditya Parikh, Eike Petersen, Stella Frank, Enzo Ferrante, Melanie Ganz +1 more
similarity 0.69
Abstract · An earlier version is available as a non-peer reviewed preprint, cited in the paper. This submission supersedes it with consent of all autho…

Encoded demographic information in internal model representations is a commonly assumed risk factor for algorithmic bias, with demographic representation invariance often being touted as the ideal state. However, while demographic shortcut learning is a genuine threat, some degree of encoding is necessary when demographics correlate with target labels. Here, we show, mathematically and empirically, that enforcing demographic invariance can actually hamper bias mitigation and even create new biases. We distinguish marginal from class-conditional representation invariance, and show that they imply the standard group fairness notions of demographic parity and equalized odds, respectively. We evaluate the effects on predictive performance and fairness of enforcing both invariance types, both theoretically and empirically across five tabular and two chest X-ray imaging datasets. Our findings support our mathematical argument that demographic representation invariance is neither desirable nor sufficient for fairness.

0.07

FRAME: Separating sampling variation from performance disparities in medical image analysis

cs.CV cs.AIcs.LG ·2026-08-26 ·Mahshad Lotfinia, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
similarity 0.68
Abstract

Fairness audits of medical imaging models commonly report the largest performance difference between demographic subgroups and treat any positive value as evidence of bias. Yet a perfectly fair model also produces a positive difference, which grows as subgroups shrink. Some mitigation methods remove demographic information from models because they assume that it produces the difference. Here we introduce Fair-model Reference And Mechanism Evaluation (FRAME). Its first step compares each reported difference with the difference expected from a perfectly fair model at the same subgroup counts. Its second step tests whether candidate causes of any excess over this fair-model reference change the difference when they are injected into model features. We evaluated 36 encoders on nine datasets in three modalities and audited 89 published differences across six modalities. For 10 frozen encoders and 13 chest radiograph findings, the reference is a median 41% of the race difference and 22% of the age difference. It is exceeded by 40 of 53 published differences in sensitivity or false positive rate and by one of 36 in the area under the receiver operating characteristic curve (AUROC). Adding race information to the features of two encoders does not change the race difference significantly. At matched disease performance, mitigation reduces the race difference by less than its spread across three pretraining seeds (medians 0.005 and 0.012) and the age difference by more (0.008 and 0.006). Image-text pretraining raises the worst-group AUROC for race by a median 0.049 over self-supervised pretraining. Reporting the fair-model reference beside every new and published subgroup difference could direct mitigation to the differences above it.

0.11

Responsible Quantum Machine Learning for Medical Imaging: A Fairness Audit Across Sensitive Subgroups

cs.LG cs.AIcs.CY ·2026-10-27 ·Giovanni dos Santos Franco, Felipe Mahlow, Ellison Fernando Cardoso, José Adenaldo Santos Bittencourt, Felipe Fanchini
similarity 0.66
Abstract

Quantum machine learning (QML) is increasingly explored for medical classification, yet its behaviour under subgroup-aware fairness criteria remains understudied. We present an empirical fairness audit of classical and quantum classifiers for medical imaging, assuming QML is not inherently fair. Two scenarios are evaluated: dermatological lesions on DDI (sensitive attribute: Fitzpatrick skin type) and chest X-rays on CheXpert-derived data (sensitive attribute: age group). Using ResNet-18 embeddings, we train SVM, MLP, QSVM and QCNN under a baseline and three mitigation settings: differentiable Equalized Odds (EO) regularisation, Gradient Reversal Learning (GRL), and both combined. Foundation models (PanDerm, EVA-X) serve as external references. Quantum classifiers may achieve competitive aggregate performance while still exhibiting subgroup disparities. Since a smaller subgroup AUC gap may stem from degrading the best group rather than improving the worst, each mitigation is also tested against a pre-specified non-inferiority margin relative to its baseline. Under this criterion, several configurations with the smallest disparity, notably QCNN with GRL on DDI, are not clinically acceptable due to loss of global discrimination. On DDI, QSVM with GRL+EO performed best and approached PanDerm in the performance/fairness trade-off; on CheXpert, QCNN with GRL achieved the highest aggregate performance but increased disparity, and EVA-X remained stronger. Fairness effects are model- and dataset-dependent, so QML requires empirical subgroup-aware evaluation. All quantum models run in classical simulation; we claim no quantum advantage.

0.25

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.66
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06

Intersectional Invariant Learning for Fair Deepfake Detection

cs.CV ·2026-10-27 ·Uzoamaka Ezeakunne, Taiwo Olabamipe, Deevesh Jain, Xiuwen Liu
benchmarkhot direction similarity 0.66
Abstract · 4 pages including appendices, 7 figures, 8 tables

Deepfake detection models achieve high overall accuracy but exhibit large performance disparities across demographic groups, causing some groups to experience substantially higher false-positive rates than others. Existing fairness-aware methods address this by constraining model outputs to equalize group predictions, but do not tackle the underlying feature-level bias. As a result, models may still rely on demographic characteristics, such as skin texture, as indirect cues for detecting manipulated content. To address this problem, we propose Intersectional Invariant Learning (IIL), a framework that improves feature learning rather than only adjusting model outputs. IIL alternates between identifying the most challenging demographic partitions and learning features that remain consistent across those partitions. The framework also includes a false-positive-rate fairness objective and group-balanced sampling across six gender x skin-tone intersectional groups. We evaluate IIL on a large-scale fairness benchmark containing over one million images, 10 baseline detectors, and 21 fairness and utility metrics. Results show that IIL achieves Pareto-optimal performance, simultaneously attaining an AUC above 99%, a false-positive rate under 2.5%, and the lowest intersectional fairness disparity (FMEO) among all compared methods. IIL outperforms prior fairness-aware methods on the large majority of the 21 evaluation metrics, while reducing both false-positive rates and intersectional fairness disparities by several-fold compared with the strongest competing method.

0.24

Prevalence calibration as shortcut mitigation

cs.LG cs.CV ·2026-09-07 ·Mohamed Amine Kina, Eike Petersen
published similarity 0.65
Abstract · Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction with MICCAI 2026. 11 pag…

Shortcut learning denotes the widespread situation in which a classifier exploits spurious correlations rather than diagnostic features. Existing mitigation strategies mostly aim to learn shortcut-invariant representations; their empirical success is limited and they cannot be applied to classifiers using frozen foundation model encoders. We propose to reframe shortcut learning as fundamentally a calibration problem: unconstrained learning implicitly calibrates each shortcut group to its training set disease prevalence, rendering the resulting classifier necessarily over-confident in one group and under-confident in the other. Building on this insight, we prevalence-equalize calibration between shortcut groups through two encoder-agnostic methods, an in-processing regularizer and a post-hoc prevalence-equalized recalibration step. Across chest-drain-pneumothorax benchmarks on CheXpert and SIIM-ACR, spanning fine-tuned CNNs and frozen foundation-model backbones, both methods substantially outperform all baselines. Post-hoc recalibration of a standard ERM-trained DenseNet raises misaligned-group AUROC from 0.23 to 0.73, indicating that shortcut reliance degrades the classification head rather than the underlying representation. Besides two new state-of-the-art shortcut mitigation approaches, our findings more fundamentally connect shortcut learning to calibration theory and algorithmic fairness.

0.45

How well do routinely collected demographic and clinical variables aid point-of-care lung ultrasound TB classification

eess.IV cs.CVcs.LG ·2026-10-05 ·Joshua M. Jansen van Vüren, Christiaan M. Geldenhuys, Devendra S. Parihar, Véronique Suttels, Trevor Brokowski +5 more
published similarity 0.64
Abstract · Accepted: SATNAC, Drakensberg, South Africa, 2026

We consider the fusion of lung ultrasound images with routinely-collected clinical and demographic data for the purpose of automated tuberculosis (TB) screening using deep-learning. Such deep-learning based screening tools for TB could meaningfully support the health care system in Africa, where the burden of disease is severe and resources are constrained. Beginning with an established ResNet baseline for classification of lung ultrasound images, which achieves an area under the receiver operating characteristic (AUROC) curve of 0.91 [0.86,0.96] (95% CI), we consider the incorporation of the clinical and demographic data using three fusion approaches. We find that a simple average-based fusion of the output scores of separately-trained image and clinical data classifiers consistently matches or outperforms a more complex approach where the data is fused earlier and a combined classifier is trained. Fusing the image and the clinical classifiers in this way leads to a classifier with an overall AUROC of 0.95 [0.91,0.99] (specificity of 0.76 at sensitivity 0.93) which is an improvement of 4% absolute over the image-only baseline. We also find that greedy feature selection can be used to reduce the number of clinical and demographic inputs without sacrificing classification performance. Finally, when we differentiate between clinical and demographic data that are self-reported, that require some basic measurement or calculation, and that require a point-of-care (POC) test, we find the inclusion of the POC tests included in this study to be of minimal benefit to classification performance. We conclude that the incorporation of routinely-collected clinical and demographic data is a promising way to improve the performance of lung ultrasound based automatic classification.

0.25