CS Paper Radar

Responsible Quantum Machine Learning for Medical Imaging: A Fairness Audit Across Sensitive Subgroups

Giovanni dos Santos Franco, Felipe Mahlow, Ellison Fernando Cardoso, José Adenaldo Santos Bittencourt, Felipe Fanchini

cs.LG cs.AIcs.CY ·submitted 2026-10-27 18:33 UTC · v1

Abstract

Quantum machine learning (QML) is increasingly explored for medical classification, yet its behaviour under subgroup-aware fairness criteria remains understudied. We present an empirical fairness audit of classical and quantum classifiers for medical imaging, assuming QML is not inherently fair. Two scenarios are evaluated: dermatological lesions on DDI (sensitive attribute: Fitzpatrick skin type) and chest X-rays on CheXpert-derived data (sensitive attribute: age group). Using ResNet-18 embeddings, we train SVM, MLP, QSVM and QCNN under a baseline and three mitigation settings: differentiable Equalized Odds (EO) regularisation, Gradient Reversal Learning (GRL), and both combined. Foundation models (PanDerm, EVA-X) serve as external references. Quantum classifiers may achieve competitive aggregate performance while still exhibiting subgroup disparities. Since a smaller subgroup AUC gap may stem from degrading the best group rather than improving the worst, each mitigation is also tested against a pre-specified non-inferiority margin relative to its baseline. Under this criterion, several configurations with the smallest disparity, notably QCNN with GRL on DDI, are not clinically acceptable due to loss of global discrimination. On DDI, QSVM with GRL+EO performed best and approached PanDerm in the performance/fairness trade-off; on CheXpert, QCNN with GRL achieved the highest aggregate performance but increased disparity, and EVA-X remained stronger. Fairness effects are model- and dataset-dependent, so QML requires empirical subgroup-aware evaluation. All quantum models run in classical simulation; we claim no quantum advantage.

Closest papers

Nearest neighbours by meaning across the whole index.

Matched but Not Better: An Equivalence-Tested Benchmark of Quantum Machine Learning on Six Clinical Datasets and the QML-Health-READY Reporting Framework

cs.LG ·2026-11-03 ·Mohammed Siraj B, Gousia Habib, Ruban S
benchmark similarity 0.68
Abstract

Background: Quantum machine learning (QML) is promoted for clinical prediction, but comparisons with classical models are rarely paired or tested for equivalence. Methods: We compared a quantum-kernel support vector machine (QSVM; 4 qubits, tuned bandwidth) and a variational quantum classifier (VQC) with five tuned classical models across six public clinical datasets. All models used identical four-component inputs and 25 cross-validation splits. Paired AUROC differences were assessed using a corrected resampled t-test, Holm-adjusted equivalence tests (margins: +/-0.02 and +/-0.05), and random-effects pooling. Ablation, noise, finite-shot, and implementation-fault analyses were conducted. We propose QML-Health-READY, an eight-domain reporting framework. Results: Neither quantum model significantly outperformed any classical comparator. Pooled across datasets, QSVM differed from the kernel-matched radial basis function (RBF) SVM by -0.006 AUROC (95% CI: -0.017 to +0.004), equivalent to +/-0.02. VQC differed from the best classical model by -0.007 (95% CI: -0.019 to +0.004). QSVM was equivalent to RBF SVM within +/-0.05 in four of six datasets but was significantly worse than the best classical model on NHANES 2017-18 (-0.076). A classically trivial product-state kernel performed as well as the entangling kernel. With depolarizing noise (p = 0.01) and 1,024 shots per kernel entry, QSVM AUROC decreased by 0.054 (95% CI: 0.036 to 0.071). Untuned bandwidth produced near-chance AUROC (0.48-0.59). Conclusions: Correctly configured quantum classifiers approached but did not exceed tuned classical models. Finite-shot estimation, rather than gate noise, was their main practical cost, while configuration errors could reverse conclusions. QML-Health-READY defines reporting requirements for credible claims.

0.04

Generative Quantum Machine Learning Methods for Cancer Detection using Augmented Datasets

eess.IV cs.CVcs.ETquant-ph ·2026-10-10 ·Sophia Knutson, Nandika Goyal, Gennaro De Luca, Glen Uehara, Tanay Kamlesh Patel +1 more
similarity 0.66
Abstract

Cancer detection using AI methods and image databases faces several challenges, including limited and imbalanced image datasets, long algorithm training times, and high-complexity feature generation. In particular, many cancer image datasets contain very few malignant examples compared to benign ones, limiting the amount of minority-class data available for training. Although classical AI and especially deep learning methods have had some success in providing cancer diagnostics, Quantum Machine Learning (QML) methods may offer advantages through high-dimensional feature representations, generative data augmentation, and the exploitation of feature correlations through quantum properties such as entanglement. In this paper, we propose using a generative QML method on the compressed breast ultrasound image dataset (BUSI) to generate synthetic images and hence augmented datasets for classifier training. In particular, we train a convolutional neural network with real, synthetic, and a combination of real and synthetic images. We test the algorithm on real images and provide comparative results for all three training cases. Our results show that the classifier trained entirely on synthetic images achieved an AUC-ROC of 0.802 (80.2%), compared with 0.760 (76.0%) for the real-data baseline.

0.15

Representation Disentanglement for Fair Chest X-Ray Diagnosis

cs.CV cs.AI ·2026-10-05 ·Yujie Sun, Ruizhe Li, Xiaowu Sun
code/data similarity 0.66
Abstract · submit to ICASSP 2027

Deep learning has advanced chest X-ray (CXR) diagnosis, yet demographic biases in learned representations may contribute to performance disparities across intersectional groups. We propose a single-encoder framework combining dual-level decorrelation with prototype-guided cross-group contrastive learning to reduce demographic dependence while accounting for within-class variation. We further propose Demographic Representation Alignment Reduction (DRAR), a new metric that quantifies the reduction in demographic structure within disease representations. The framework is evaluated on four classification tasks using 34,809 CheXpert test images across eight intersectional groups, defined by age, sex and ethnicity. Compared with empirical risk minimization (ERM), our method reduces the mean equalized-odds gap from 15.41\% to 10.86\% and the AUC gap from 5.95\% to 5.01\%. Our method achieves a DRAR of 59.04\% relative to ERM, with only a slight decrease in mean AUC. These results demonstrate that representation disentanglement can reduce demographic bias and improve intersectional fairness. Code is available at \url{https://github.com/06Yujie/Fair-Medical-Imaging}.

0.25

How Quantum Is the Advantage? A Fair, Calibration- and Noise-Aware Benchmark and Attribution Audit of Quantum Machine Learning for Network Intrusion Detection

cs.AI quant-phcs.ETcs.LG ·2026-08-13 ·Syeda Anshrah Gillani, Mirza Samad Ahmed Baig, Shahid Munir Shah, Asher Ali, Hamzah Siddiqui
benchmarkcode/data similarity 0.65
Abstract · 19 pages, 4 figures, 5 tables

Quantum machine learning (QML) for network intrusion detection (NIDS) is routinely reported to reach near-perfect accuracy, yet the most rigorous studies find that well-tuned classical models remain competitive, and that apparent quantum gains may be artefacts of classical dimensionality reduction and implicit regularisation rather than genuine quantum effects. We ask not whether a quantum model can post a high accuracy, but how quantum the advantage really is. We present a unified, reproducible QML-IDS benchmark evaluating hybrid variational quantum circuits and quantum-kernel SVMs against five honestly-tuned classical baselines across four standard NIDS datasets (NSL-KDD, UNSW-NB15, CICIDS2017, NF-ToN-IoT-v2) under one leakage-controlled protocol, with an equal-budget feature view, imbalance- and calibration-aware metrics with significance testing, and a simulated NISQ noise sweep. We introduce a quantum-attribution audit (parameter-matched classical controls, a random-feature kernel, and a regularisation sweep) that quantifies how much of any gain is genuinely attributable to the quantum component. Tuned classical models (Random Forest, XGBoost) match or exceed the quantum models on aggregate detection on every dataset, and the audit attributes this to classical preprocessing and regularisation rather than quantum effects. Two advantages survive false-discovery-rate correction: the quantum-kernel SVM out-ranks its direct classical surrogate (a random-feature kernel) on AUPRC and ROC-AUC, and a small four-qubit hybrid out-detects the best classical baseline at the 1% false-positive operating point on the distribution-shifted NSL-KDD task (p = 0.005, BH q = 0.030). Code, seeds, and splits are released; our contribution stands whether quantum wins, ties, or loses.

0.63

KQML-Liver: Interpretable Hybrid Quantum Machine Learning with Kolmogorov-Arnold Networks for Liver Disease Classification

cs.LG cs.AI ·2026-11-11 ·Nhat-Long Nguyen, Viet-Loi Dinh, Trong-Nghia Pham
similarity 0.63
Abstract

Liver disease remains a major global health concern, highlighting the need for reliable and accessible early detection methods. Although recent advances in machine learning, deep learning and quantum machine learning (QML) have introduced promising diagnostic tools, many approaches suffer from limited interpretability and inflated performance caused by data leakage or overly simplistic evaluation protocols. These constraints reduce their reliability in real-world clinical practice. This paper proposes KQML-Liver, a hybrid framework that integrates QML with Kolmogorov-Arnold Networks (KANs) to enhance predictive performance and interpretability. The architecture combines parameterized quantum circuits for expressive feature representation with KAN-based functional mappings that capture nonlinear relationships in an interpretable manner. Evaluated on the Indian Liver Patient Dataset (ILPD) under a rigorous preprocessing protocol preventing data leakage, the proposed model achieves 82% classification accuracy and 100% recall, detecting all positive cases, outperforming existing baselines while providing improved transparency in clinical predictions. These results suggest that hybrid KAN-quantum architectures offer a promising direction for interpretable AI-assisted medical diagnosis.

0.09

False-Alarm Improvements and Detection Trade-Offs in Quantum Machine Learning for Intrusion Detection: A Reproducible Secondary Analysis

cs.CR ·2026-10-26 ·Roberto Fernández-Barrios, Iker Pastor-López, Asier González-Santocildes, Pablo García Bringas
similarity 0.63
Abstract · 15 pages, 2 figures. Revised title, presentation, panel labels and bibliographic details; scientific results unchanged. Supplementary materi…

Published results in quantum machine learning for intrusion detection (QML-IDS) require joint interpretation of false-positive rate (FPR), attack true-positive rate (TPR), and evaluation provenance. We reconstruct operating points in the 25-entry frame selected by Kaissar and colleagues: 21 included articles, 20 identified documentary families, substantive methodological material consulted for 15, and 24 descriptive points from five. In one test-labelled comparison, a quantum support vector machine reduces FPR from 6.875% for random forest to 3.329%, while TPR decreases from 93.955% to 93.682%; both rates improve against three other comparators. In another study, a complete benign row identifies FPR as 12/6000 (0.200%), despite incomplete attack-side allocation that requires additional assumptions for TPR. Normalized matrices identify detection ranges rather than a unique aggregate rate. A uniform provenance rule separates training-described and test-adjusted results from six conditional illustrations whose independence remains unverified. The contribution is a reproducible interpretation of favorable comparisons and detection trade-offs, without converting descriptive results or hypothetical calculations into operational guarantees.

0.25

Comparative Study of Quantum and Classical Machine Learning Models in Binary Classification

cs.LG quant-ph ·2026-09-20 ·Anand Kumar Mishra, Ramanuj Awasthi
similarity 0.63
Abstract

A potential path forward is Quantum Machine Learning (QML), which aims to leverage quantum computing in conjunction with classical machine learning to enhance computing efficiency and the expressiveness of models. In this paper, two different quantum classifiers - Variational Quantum Classifier (VQC) and Quantum Kernel Support Vector Machine (QSVM) - are compared with three classical classifiers as baseline classifiers - Logistic Regression, Support Vector Machine (SVM), and a Multi-Layer Perceptron (MLP) - on the Breast Cancer Wisconsin dataset. The quantum circuits were created in the PennyLane framework and simulated on a classical backend. However, in terms of accuracy, classical Logistic Regression performed better with an accuracy of 97.8%, classical SVM and QSVM with an accuracy of 95.6% each, although the Quantum VQC achieved a lower accuracy of 88.9% and had a recall of 100% for the benign class, though it correctly identified only 12 of the 17 malignant cases (a malignant-class recall of approximately 70.6%). The drawback of quantum models is the higher training time; however, since the quantum circuit needs to be classically simulated, the quantum SVM took 23.29 seconds compared to less than 0.01 seconds for the classical linear models. These results indicate that for small structured datasets, classifiers based on quantum computing have not yet surpassed well-tuned classical counterparts. In some respects (e.g., benign-class recall), they perform competitively, though not on malignant-class recall, where the VQC in particular performed worse than the classical baselines, which is worth further investigation on real quantum computers.

0.16

Benchmarking Quantum Kernel SVMs for Credit Card Fraud Detection: Performance Realities Under NISQ Constraints

cs.AI ·2026-10-12 ·Hitanshi Arora, Mohit Swarnkar, Aswani Kumar Cherukuri
benchmark similarity 0.62
Abstract

Detecting credit card fraud is notoriously difficult because fraudulent charges make up less than 0.2% of total transactions. Quantum Machine Learning (QML), particularly Quantum Kernel Support Vector Machines (QSVM), promises richer feature representations by embedding classical data into high-dimensional Hilbert spaces. However, whether this theoretical advantage holds up when managing real-world financial data bottlenecks remains unclear. We designed a controlled benchmark comparing three quantum encodings, Angle, ZZFeatureMap, and IQP against classical models while keeping sample sizes, feature counts, and scaling strictly matched. To handle class skew without corrupting quantum state overlaps, we embedded synthetic minority oversampling (SMOTE) directly into the quantum Gram matrix workflow, raising PR-AUC scores by roughly +0.04 across feature maps. When trained on the full European credit card dataset with 30 features, classical baselines reached a top PR-AUC of 0.983. However, restricting classical models to match QSVM hardware constraints (500 samples, 4 PCA features) dropped their PR-AUC to 0.750. This puts our best quantum result 0.730 PR-AUC using IQP encoding on 150 samples into realistic context. Testing on physical quantum hardware reduced performance further to 0.62 due to CNOT gate errors and thermal noise. Overall, our findings pinpoint two main operational bottlenecks for near-term quantum kernels: the scaling of Gram matrix evaluation and heavy information loss from squeezing features onto small qubit registers.

0.11