CS Paper Radar

Subgroup performance analysis of adaptation strategies for chest X-ray foundation models

Dhruv Gupta, Emma A. M. Stanley, Fabio De Sousa Ribeiro, Sujal R. Desai, Ben Glocker

cs.CV ·submitted 2026-08-19 16:25 UTC · v2
published

Abstract

Foundation models are increasingly adapted for downstream medical imaging tasks, yet the influence of the chosen adaptation strategy on subgroup fairness remains poorly understood. We investigate how three parameter-efficient adaptation techniques, including linear heads on the raw CLS token, an MLP, and an attention-pooling module over multi-layer patch features, affect both pathology classification performance and subgroup disparities when applied to the frozen Rad-DINO chest X-ray encoder. Using MIMIC-CXR, we evaluate eight pathologies across race, sex, and imaging-view subgroups on a prevalence-preserving, demographically balanced test set, and additionally probe how strongly each adapter encodes protected attributes. We find that attention pooling achieves the strongest overall discriminative performance and encodes attributes, particularly race, most strongly, but that improved overall performance does not consistently reduce subgroup disparities. Notably, stronger attribute encoding did not correspond to larger disparities: early network layers encoded race most weakly yet produced the largest subgroup performance gaps. Exploring different attention-pooling layer combinations further revealed no consistent relationship between the layers pooled, attribute encoding strength, and subgroup fairness. Our results indicate that richer, more expressive representations can improve accuracy while leaving fairness implications task-dependent and unpredictable, which must be assessed directly and per-task rather than inferred from encoding strength or overall performance alone.

Comment
Accepted at MICCAI Workshop on Fairness of AI in Medical Imaging (FAIMI) 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Representation Disentanglement for Fair Chest X-Ray Diagnosis

cs.CV cs.AI ·2026-10-05 ·Yujie Sun, Ruizhe Li, Xiaowu Sun
code/data similarity 0.74
Abstract · submit to ICASSP 2027

Deep learning has advanced chest X-ray (CXR) diagnosis, yet demographic biases in learned representations may contribute to performance disparities across intersectional groups. We propose a single-encoder framework combining dual-level decorrelation with prototype-guided cross-group contrastive learning to reduce demographic dependence while accounting for within-class variation. We further propose Demographic Representation Alignment Reduction (DRAR), a new metric that quantifies the reduction in demographic structure within disease representations. The framework is evaluated on four classification tasks using 34,809 CheXpert test images across eight intersectional groups, defined by age, sex and ethnicity. Compared with empirical risk minimization (ERM), our method reduces the mean equalized-odds gap from 15.41\% to 10.86\% and the AUC gap from 5.95\% to 5.01\%. Our method achieves a DRAR of 59.04\% relative to ERM, with only a slight decrease in mean AUC. These results demonstrate that representation disentanglement can reduce demographic bias and improve intersectional fairness. Code is available at \url{https://github.com/06Yujie/Fair-Medical-Imaging}.

0.25

From Adults to Children: Benchmarking Foundation Models for Chest X-Ray Classification under Domain Shift

cs.CV ·2026-10-15 ·Sara Inácio, Hugo Proença, João C. Neves
publishedbenchmark similarity 0.72
Abstract · Accepted at WACV 2027

Foundation models have shown significant potential across diverse fields and have been applied to medical imaging, but their robustness across patient populations remains unclear. In this work, we investigate foundation models' ability to generalize from adult to pediatric chest X-ray classification. To the best of our knowledge, this is the first benchmark to compare multiple foundation models under a common adult-to-pediatric evaluation setting while also analyzing the effect of adaptation depth. We harmonize VinDr-CXR and PediCXR into a five-label classification task and evaluate six foundation models and two CNN baselines. All models are adapted using adult data only and tested in both the in-domain and pediatric domains using linear probing, partial fine-tuning, and full fine-tuning. The benchmark reveals a clear and consistent trend: all models suffer a substantial performance degradation when transferred from adult to pediatric data, with drops exceeding 10 percentage points. While Macro-AUROC values reach approximately 92% on the adult test set, performance decreases to around 78% on the pediatric domain. Another important finding is that increasing the depth of adaptation improves pediatric performance on average, although the effect varies across models. Moreover, strong in-domain performance does not necessarily indicate greater robustness to domain shift.

0.40

FRAME: Separating sampling variation from performance disparities in medical image analysis

cs.CV cs.AIcs.LG ·2026-08-26 ·Mahshad Lotfinia, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
similarity 0.68
Abstract

Fairness audits of medical imaging models commonly report the largest performance difference between demographic subgroups and treat any positive value as evidence of bias. Yet a perfectly fair model also produces a positive difference, which grows as subgroups shrink. Some mitigation methods remove demographic information from models because they assume that it produces the difference. Here we introduce Fair-model Reference And Mechanism Evaluation (FRAME). Its first step compares each reported difference with the difference expected from a perfectly fair model at the same subgroup counts. Its second step tests whether candidate causes of any excess over this fair-model reference change the difference when they are injected into model features. We evaluated 36 encoders on nine datasets in three modalities and audited 89 published differences across six modalities. For 10 frozen encoders and 13 chest radiograph findings, the reference is a median 41% of the race difference and 22% of the age difference. It is exceeded by 40 of 53 published differences in sensitivity or false positive rate and by one of 36 in the area under the receiver operating characteristic curve (AUROC). Adding race information to the features of two encoders does not change the race difference significantly. At matched disease performance, mitigation reduces the race difference by less than its spread across three pretraining seeds (medians 0.005 and 0.012) and the age difference by more (0.008 and 0.006). Image-text pretraining raises the worst-group AUROC for race by a median 0.049 over self-supervised pretraining. Reporting the fair-model reference beside every new and published subgroup difference could direct mitigation to the differences above it.

0.11

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.66
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.51

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.65
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.26

Federated LoRA Adaptation of BiomedCLIP Across Four International Chest X-Ray Cohorts

cs.LG cs.AIcs.CV ·2026-09-02 ·Sanjaya Poudel, Nirajan Kunwor, Manish Dhakal, Debesh Jha, Sunil Kumar Gaire
benchmark similarity 0.64
Abstract

Federated learning (FL) lets institutions train a shared model without exchanging data, and Low-Rank Adaptation (LoRA) makes this practical at scale by communicating only compact low-rank updates. Biomedical imaging is a compelling setting for this combination: patient data are archived behind privacy regulations, and institutions differ widely in scanners, protocols, and compute. Such heterogeneity raises the question of how federated LoRA updates should be aggregated, increasingly pressing as multimodal vision-language models become central to medical image analysis. We benchmark federated Parameter-efficient fine-tuning (PEFT) of BiomedCLIP for chest radiograph classification across four public cohorts on three continents (USA, Vietnam, Spain). Federated LoRA adaptation improves shared-class AUC on all four cohorts over the unadapted BiomedCLIP backbone (mean 0.687 to 0.802), showing that the gains come from federated adaptation rather than from the pretrained model's zero-shot ability. Relative to isolated single-cohort training, federation improves the weaker cohorts while largely preserving the strongest and approaches a centralized reference (0.812) that pools all data. The singular value decomposition (SVD)-based product-space aggregation introduced by FlexLoRA is essential to this gain (naive factor averaging drops mean AUC by 0.097), whereas a drift-correcting optimizer (FedProx) shows no benefit over FedAvg in our single-seed runs, consistent with LoRA's low-rank updates already limiting client drift. Biomedical vision-language models can thus be adapted collaboratively across heterogeneous, geographically distributed institutions without centralizing data.

0.11

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
similarity 0.64
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

Is invariance all you need for algorithmic fairness? Removing demographic information can create new bias

cs.LG cs.AI ·2026-09-25 ·Aditya Parikh, Eike Petersen, Stella Frank, Enzo Ferrante, Melanie Ganz +1 more
similarity 0.63
Abstract · An earlier version is available as a non-peer reviewed preprint, cited in the paper. This submission supersedes it with consent of all autho…

Encoded demographic information in internal model representations is a commonly assumed risk factor for algorithmic bias, with demographic representation invariance often being touted as the ideal state. However, while demographic shortcut learning is a genuine threat, some degree of encoding is necessary when demographics correlate with target labels. Here, we show, mathematically and empirically, that enforcing demographic invariance can actually hamper bias mitigation and even create new biases. We distinguish marginal from class-conditional representation invariance, and show that they imply the standard group fairness notions of demographic parity and equalized odds, respectively. We evaluate the effects on predictive performance and fairness of enforcing both invariance types, both theoretically and empirically across five tabular and two chest X-ray imaging datasets. Our findings support our mathematical argument that demographic representation invariance is neither desirable nor sufficient for fairness.

0.07