CS Paper Radar

ConfTriage: A Calibration-Aware LLM Triage Framework for Pulmonary Nodule Malignancy with Selective Specialist Deferral

Md Rabiul Islam, Samir Abdaljalil, Erchin Serpedin, Hasan Kurban

cs.CV ·submitted 2026-08-11 13:02 UTC · v1
theorycode/data

Abstract

Pulmonary nodule malignancy prediction typically depends on image-trained specialist deep learning (DL) models that require substantial annotated imaging data and task-specific training. We investigate whether a generalist large language model (LLM), reading only a faithful natural-language rendering of standard nodule attributes, can serve as a calibrated triage layer. We propose ConfTriage, a confidence-calibrated method built on three pillars: language as the modality, calibration as the safety mechanism, and a selective specialist DL backstop for low-confidence cases. We prove two guarantees: a finite-sample combined-error bound yielding an explicit per-threshold operational certificate, and an oracle inequality showing that excess risk over the Bayes-optimal deferral classifier is controlled by the L1 calibration error of the LLM probability. A controlled seven-way input ablation across five frontier LLMs on LIDC-IDRI shows that natural-language descriptions dominate the diagnostic signal, while low-level image statistics are essentially diagnostically vacuous. ConfTriage achieved an F1 score of 88.22% and an AUC of 0.92, resolving 76.5% of cases using zero-shot LLM inference alone and referring only uncertain cases to the specialist DL backstop. These results demonstrate that clinically meaningful diagnostic information can be captured through structured radiological descriptions and leveraged by calibrated LLMs for selective referral. The framework suggests a practical pathway for combining generalist LLM prediction with specialist AI models in medical decision-support systems. Source code is publicly available at https://github.com/rabiul-ai/ConfTriage.

Comment
14 pages, 8 figures. Currently under review

Closest papers

Nearest neighbours by meaning across the whole index.

Less Annotation, More Interpretation: Prior-Guided Concept Bottleneck Models for Interpretable Cancer Imaging Diagnosis

cs.CV ·2026-08-13 ·Baoqiang Ma, Kenneth Gilhuijs
published similarity 0.71
Abstract · Accepted at the iMIMIC Workshop at MICCAI 2026

Concept bottleneck models (CBMs) can improve the transparency of cancer image diagnostic prediction by expressing predictions through radiological concepts. However, their dependence on instance-level concept annotations limits practical applicability. We propose a prior-guided hybrid CBM that integrates limited concept annotations, class-conditional concept distribution matching on unannotated patients, and prior initialization of the concept-to-diagnosis head. We evaluate the method on CBIS-DDSM mammographic masses and calcifications and LIDC-IDRI pulmonary nodules across 0-100% concept annotation. In the clinically relevant 0-20% annotation regime, the hybrid CBM consistently improves mean concept AUC over a matched standard CBM, while maintaining diagnostic performance close to black-box models. At 10% annotation specifically, concept AUC increases from 0.619 to 0.741 for masses, from 0.650 to 0.787 for calcifications, and from 0.597 to 0.642 for pulmonary nodules. Ablation experiments identify prior initialization as the main component contributing to improved concept detection, likely by stabilizing the concept-to-diagnosis head. Zero-shot VLMs remain insufficient for reliable fine-grained tumor-level concept prediction. These findings suggest that structured priors can substantially reduce the annotation burden of interpretable cancer imaging models.

0.18

Uncertainty-driven training for three-dimensional calibrated lung nodule classification

eess.IV cs.CV ·2026-09-17 ·Giuseppe Tripodi, Alessandro De Rosis, Saleh Rezaeiravesh
publishedbenchmark similarity 0.70
Abstract

In this work, we present an uncertainty-driven training framework for three-dimensional computed tomography (CT) lung nodule classification, where validation-based uncertainty estimates guide loss reweighting to enhance predictive performance and probability calibration. Two Uncertainty Quantification (UQ) methods are considered: Monte Carlo Dropout (MCD) and Evidential Deep Learning (EDL). Both provide per-class uncertainty estimates that modulate the loss and encourage focus on hard or unreliable classes. The framework is evaluated with ResNet, DenseNet, EfficientNet, Vision Transformer (ViT), and Swin Transformer backbones on two datasets: the clinical LIDC-IDRI cohort and the NoduleMNIST3D benchmark. Uncertainty-driven training achieves classification performance similar to conventional training while substantially improving calibration, with an expected calibration error (ECE) reduced by up to 65% on LIDC-IDRI. EDL attains competitive performance on shallower architectures with single-pass inference, whereas MCD is more robust on deeper networks. Analysis across architectural families reveals that uncertainty-driven training benefits convolutional backbones more consistently than transformer-based architectures: EDL in particular degrades on ViT, suggesting that the Dirichlet evidence parameterisation may interact unfavourably with attention-based architectures at lower input resolutions. A posteriori temperature scaling proves highly effective across all configurations, indicating that a simple scalar calibration can be competitive even without explicit uncertainty-aware training. Our results indicate that integrating UQ into the training loop can significantly improve probabilistic calibration and support more trustworthy deployment of three-dimensional medical imaging models.

0.19

FZ-VLM: A Two Stage Florence-Zephyr Vision Language Model Framework for Pulmonary Nodule Characterization and Clinical Decision Making

cs.CV cs.AI ·2026-08-15 ·Pramit Dutta, Jenita Manokaran, Richa Mittal, Ryan Appleby, Eranga Ukwatta
similarity 0.70
Abstract

Lung cancer remains one of the leading causes of cancer-related mortality worldwide, and Computed Tomography (CT) is a primary imaging tool for screening and followup assessment. After pulmonary nodule detection, radiologists manually assess anatomical location, diameter, margin characteristics, and attenuation type to support risk assessment and clinical decision-making. However, this post-detection workflow is time-consuming and can be affected by inter-observer variability. Existing Artificial Intelligence methods often focus on isolated tasks, limiting their use as a unified, clinically grounded interpretation framework. This study presents FZ-VLM, a two-stage Florence-Zephyr Vision Language Model framework for unified structured pulmonary nodule characterization in lung CT. The framework uses a fine-tuned Florence-2 model to extract radiological attributes from expert-annotated 2D axial CT slices, while a Zephyr-7B model uses these attributes to generate nodule descriptions, follow-up recommendations, and longitudinal analyses. Results showed that the Stage 1 model achieved 77.18\% accuracy for anatomical location, 67.96\% accuracy for margin characteristics, and 79.13\% accuracy for attenuation type, with a Mean Absolute Error of 2.58 mm for diameter estimation, outperforming evaluated GPT-4-based baselines as well as the human baseline. Expert radiologist evaluation of Stage 2 showed 93.9\% accuracy, 98.6\% completeness score, 76.1\% clinical relevance, and an overall score of 89.5\%. Safety analysis showed that most outputs were clinically safe, although some follow-up recommendations still required expert review. To the best of our knowledge, this study presents the first two-stage Vision-Language Model framework for structured nodule characterization and clinical decision-making.

0.04

Evaluating Multi-Task Morphological Concept Learning for Pulmonary Nodule Malignancy Assessment in 3D CT

cs.CV ·2026-09-29 ·Namitha Narayanan
similarity 0.69
Abstract · 8 pages, 3 figures, 5 tables

Morphological characteristics such as spiculation and lobulation play an important role in assessing pulmonary nodules on computed tomography (CT), particularly in relation to malignancy risk. This study examines whether learning radiologist-annotated morphological features together with malignancy risk from lesion-centred 3D CT volumes improves classification performance. The Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset was used, comprising 3,918 reader-level nodule annotations from 742 patients after excluding indeterminate malignancy ratings. Patient-level splitting was used for training, validation, and testing, with 112 patients and 628 reader annotations in the held-out test set. A single-task 3D convolutional neural network was compared with a multi-task model predicting malignancy risk, spiculation, and lobulation. The single-task model achieved a balanced accuracy of 0.548 and receiver operating characteristic area under the curve (ROC-AUC) of 0.552, while the multi-task model achieved 0.539 and 0.558, respectively. Patient-level bootstrap analysis showed an ROC-AUC difference of 0.005 (95% confidence interval (CI): -0.087 to 0.090) and a balanced-accuracy difference of -0.009 (95% CI: -0.067 to 0.043). The auxiliary tasks were strongly imbalanced and showed limited predictive performance. Overall, including morphological features did not clearly improve malignancy-risk classification, showing the importance of class balance, label formulation, and reader-level annotation structure in multi-task pulmonary CT analysis.

0.15

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.67
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification

cs.CV cs.AI ·2026-08-14 ·Bingxin Yu, Xueli Wang, Jerry Zhou, Wenyan Wang, Li Wen +4 more
datasetcode/data similarity 0.67
Abstract

Ultrasound is the primary imaging modality for assessing thyroid nodules, and the ACR TI-RADS framework standardizes diagnosis through five ultrasound feature categories that are aggregated into five risk levels (TR1-TR5). Although widely adopted in clinical practice, most deep learning approaches focus on binary malignancy classification, while multi-class prediction and explicit utilization of feature-level supervision remain underexplored, largely due to limited annotated data. In this study, we introduce the STN dataset of 600 thyroid nodules with paired transverse and longitudinal ultrasound images, bounding box annotations, and complete labels for all five TI-RADS feature categories. Following the clinical decision process, we investigate how structured feature information can guide representation learning during training while requiring only images at inference. We demonstrate that text embeddings derived from standardized feature descriptions form a stable surrogate representation for TI-RADS risk levels. Based on this observation, we propose CMCNet, which aligns image embeddings to fixed textual embeddings via a Center-Margin Contrastive Loss that simultaneously promotes intra-class compactness and inter-class separation. Experimental results show that this embedding alignment strategy is more data-efficient and robust than direct multitask learning, and consistently outperforms InfoNCE, center loss, a strong multitask baseline, and a VQA-style multimodal model, particularly in imbalanced settings. The dataset is freely available at doi: 10.5281/zenodo.19125693 and the source code is available at: https://www.healthinformaticslab.org/supp/.

0.20

Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation

cs.CV cs.LG ·2026-08-14 ·Simon Baur, Arne Schernich, Ekin Böke, Wojciech Samek, Jackie Ma
similarity 0.67
Abstract

Uncertainty estimation is critical for the safe clinical deployment of deep learning in medical image segmentation, with aleatoric uncertainty theoretically designed to capture irreducible data ambiguity. However, whether entropy-based measures reflect clinically meaningful ambiguity, i.e. case-level disagreement about whether a pathology is present at all, remains poorly understood. Contrary to most prior work, which focused on pixel-wise boundary disagreement, we systematically evaluate how well aleatoric uncertainty captures presence ambiguity. Our evaluation spans 3D lung nodule segmentation across four architectures with Monte Carlo dropout and deep ensembles, on LIDC-IDRI and an external validation cohort (LNDb). We find that entropy-based uncertainty maps align with boundary noise and minor drawing variation but carry insufficient discriminative signal for presence ambiguity. In contrast, a lightweight supervised ambiguity head trained on frozen segmentation features substantially outperforms all entropy-aggregation-based baselines across architectures, metrics, and both cohorts, and matches or exceeds methods that explicitly model ambiguity under disagreement supervision (Probabilistic U-Net, Annotator-Confusion 3D-UNet). A qualitative feature-space analysis shows that presence ambiguity is already encoded in the frozen encoder features of pixel-wise-trained networks, only to be discarded by the segmentation output and its entropy aggregation. Our findings expose a fundamental mismatch between the theoretical promise of aleatoric uncertainty and its practical behavior, and suggest that practitioners should not rely on entropy-based uncertainty as a proxy for clinical ambiguity in safety-critical applications.

0.34

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.67
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28