CS Paper Radar

Daily listing

2026-11-22 · eess.SP

15 papers first submitted this day (UTC) in eess.SP — Signal Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 2

Denoised but Not Improved: What EEG Denoising Does to a Downstream Task

cs.LG cs.AIeess.SPq-bio.NC ·2026-11-22 ·Xianglong Bao, Zhe Wang, Kewen Wang, Ming Jin
published
Abstract · Accepted at the IEEE Symposium on CI in Health and Medicine

Scalp electroencephalography (EEG) is routinely denoised before it reaches a downstream model, and the denoising literature scores a method by how closely its output matches a clean reference waveform. That reference does not exist for real scalp recordings: it is synthesized by adding artifact templates to signals merely presumed clean, and even an exact separation would return cortical activity blurred by volume conduction rather than the activity itself. Fidelity to it is therefore an unvalidatable objective, and whether it predicts any downstream benefit has gone largely unexamined. We report an audit that examines it. Holding a seizure-detection pipeline fixed and varying only the preprocessing stage, we find that five standard denoising methods, spanning analytic, cross-channel and supervised deep families, all fail to improve on the unprocessed signal, and most degrade it. To say what such a stage must instead do, we formalize a label-only, classifier-free probe that reads it by the separability geometry it induces on task-relevant features, decomposing any change into a between-class distance and a within-class scatter term. On a transform that does improve the task, the probe attributes the entire gain to a roughly one-quarter reduction of within-class scatter, with class separation statistically unchanged. What a downstream model benefits from is therefore variance suppression on task-relevant structure, which waveform-fidelity metrics neither measure nor reward.

0.32

SleepXA: Composing Pretrained Neural and Cardiac Foundation Models for Sleep Representation Learning

cs.LG eess.SP ·2026-11-22 ·Xiaoyu Chen, Xiao Gu, Chao Zhang, Wen Wu, Shuaicong Hu +4 more
Abstract · 36 pages, 16 figures (9 in the main text and 7 in the appendix)

Physiological signals recorded during sleep provide synchronized views of neural, cardiac, respiratory, and other bodily systems, while preserving modality-specific information. Existing EEG and ECG foundation models already capture rich but distinct physiological structure, motivating an alternative to training a multimodal sleep model from scratch: composing existing pretrained models. We introduce SleepXA, a framework that uses synchronized polysomnography (PSG) to compose independently pretrained neural and cardiac foundation models. SleepXA combines pretrained EEG and ECG encoders with lightweight encoders for additional PSG modalities, and learns shared and modality-specific representations through sleep-guided alignment. We pretrain SleepXA on 9,230 overnight PSG recordings from three large cohorts and evaluate it on 27 downstream tasks spanning sleep representation, clinical and disease prediction, and daytime physiological transfer. SleepXA ranks among the top two methods on 22 of 27 tasks. Controlled experiments further show consistent benefits across sensor configurations and EEG-ECG backbone choices, while pretrained initialization outperforms architecture-matched training from scratch and SleepXA surpasses alternative multimodal composition strategies. These results suggest that synchronized multimodal physiology can serve as a natural interface for composing existing physiological foundation models, yielding reusable representations that extend beyond sleep to clinical and daytime physiological settings.

0.23