CS Paper Radar

Denoised but Not Improved: What EEG Denoising Does to a Downstream Task

Xianglong Bao, Zhe Wang, Kewen Wang, Ming Jin

cs.LG cs.AIeess.SPq-bio.NC ·submitted 2026-11-22 05:54 UTC · v1
published

Abstract

Scalp electroencephalography (EEG) is routinely denoised before it reaches a downstream model, and the denoising literature scores a method by how closely its output matches a clean reference waveform. That reference does not exist for real scalp recordings: it is synthesized by adding artifact templates to signals merely presumed clean, and even an exact separation would return cortical activity blurred by volume conduction rather than the activity itself. Fidelity to it is therefore an unvalidatable objective, and whether it predicts any downstream benefit has gone largely unexamined. We report an audit that examines it. Holding a seizure-detection pipeline fixed and varying only the preprocessing stage, we find that five standard denoising methods, spanning analytic, cross-channel and supervised deep families, all fail to improve on the unprocessed signal, and most degrade it. To say what such a stage must instead do, we formalize a label-only, classifier-free probe that reads it by the separability geometry it induces on task-relevant features, decomposing any change into a between-class distance and a within-class scatter term. On a transform that does improve the task, the probe attributes the entire gain to a roughly one-quarter reduction of within-class scatter, with class separation statistically unchanged. What a downstream model benefits from is therefore variance suppression on task-relevant structure, which waveform-fidelity metrics neither measure nor reward.

Comment
Accepted at the IEEE Symposium on CI in Health and Medicine

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.76
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.31

DenoFlow: Flow Matching for SSVEP Denoising under Real Physiological Artifacts

cs.LG ·2026-09-24 ·Zhentao He, Ziwei Wang, Dongrui Wu
code/data similarity 0.72
Abstract · 14 pages, 6 figures

Electroencephalography (EEG)-based brain-computer interfaces (BCIs), particularly steady-state visual evoked potential (SSVEP) systems, are highly vulnerable to noise and artifacts, which severely degrade decoding accuracy. Although recent denoising approaches have shown promise, they are fitted without paired ground truth, can settle on reproducing their input, and are optimized on waveform distance alone, which says nothing about whether the output stays decodable. To address these issues, we propose DenoFlow, which casts SSVEP denoising as transport: instead of learning a direct map from a contaminated trial to a clean one, a field network regresses the velocity of the straight path between them, following the rectified-flow formulation, and denoising integrates that field forward from the observation. The field network is an encoder-decoder that sees the contaminated trial at every layer and the path position at its bottleneck, and a classifier trained alongside it supervises the integrated output. Because the observation itself is both the conditioning input and the starting point of the integration, the model never generates a trial from noise, and training reduces to regression, removing the adversarial min-max game. To obtain paired data on datasets with no ground truth, we injected physiological artifacts of the recorded electromyography (EMG) and electrooculography (EOG) signals under a controlled signal-to-noise target. Experiments on two public SSVEP datasets with five popular SSVEP decoders showed that DenoFlow outperformed seven baseline denoising models on both signal fidelity and downstream decoding accuracy. Code is available at https://github.com/wzwvv/DenoFlow.

0.37

iEEG Can Help EEG: Improving Clinical Scalp EEG Analysis through Intracranial Priors

cs.LG eess.SPq-bio.NC ·2026-11-16 ·Xianglong Bao, Yi Ding, Zengxiang Li, Nan Liu, Kewen Wang +2 more
top venuecode/data similarity 0.72
Abstract · Accepted at KDD 2027

Scalp electroencephalography (EEG) is a cornerstone of clinical brain monitoring, making the quality of its signal fundamental to downstream tasks and models. However, that signal is heavily contaminated by non-neural interference and blurred by volume conduction. Existing methods operate almost exclusively within the scalp modality, so they inherit the contamination they would need to overcome. In practice, intracranial EEG (iEEG) observes the neural activity with far higher fidelity, yet it is invasive and therefore scarce, and the two modalities are rarely recorded as pairs at scale, share no common channel space, and offer no clean ground truth to directly supervise a mapping. Motivated by the neuronal synchronization mechanism shared by the two modalities, we propose a reprogramming approach that fits a signal-to-signal model on iEEG alone and freezes it as a cross-modal prior. We introduce ReBrain, a framework to transfer an iEEG-learned prior to scalp EEG, which re-expresses any scalp signal through that prior and can be inserted upstream of any downstream model with no pairing or fine-tuning. ReBrain consistently improves host models across recordings from multiple hospitals and across architecture families, and our analysis traces this gain to genuine neural structure carried by iEEG rather than to the architecture itself. This work provides evidence that a scarce clean modality can serve as a transferable prior for an abundant noisy one, offering a general recipe for cross-modal transfer among biosignals. Our code is available at https://github.com/Xianglong-Bao/ReBrain.

0.66

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.70
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.47

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.66
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Virtual iEEG from Scalp EEG: Charting the Landscape of Source Imaging, Intracranial Inference and Reconstruction

cs.CV ·2026-08-27 ·Dongyi He, Xiangkai Wang, Hongjie Yan, Luping Song, Wai Ting Siok +1 more
similarity 0.66
Abstract

Intracranial electroencephalography (iEEG) provides temporally precise and spatially specific access to neural activity from focal and deep brain regions, but its invasiveness and restricted anatomical coverage limit routine use. These constraints have motivated scalp-to-intracranial inference, termed virtual iEEG when model outputs carry iEEG-defined event, feature, representation, or contact-level waveform semantics. This review presents a target-centred framework distinguishing event inference, feature translation, and waveform reconstruction, while separating predictability from observability, identifiability, fidelity, and utility. Evidence is evaluated according to cohort independence, anatomical and spectral coverage, train--test separation, and target-patient adaptation. Current studies support inference of selected intracranial events, low-frequency components, and task-related representations, but not unique recovery of arbitrary contact-level activity. Stronger validation requires appropriate controls, source-imaging baselines, uncertainty assessment, and incremental-utility testing. Future progress depends on independent paired datasets and prospective evidence that virtual iEEG adds value beyond scalp EEG and EEG source imaging.

0.22

PHASE: A Physiology-Guided Hierarchical Foundation Model for Intracranial EEG

cs.LG cs.AI ·2026-09-28 ·Yipeng Zhang, Chenda Duan, Yuanyi Ding, Tianyi Wang, Atsuro Daida +8 more
benchmark similarity 0.65
Abstract · Author Metadata Correction

Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristics, which carry much of the information that downstream tasks depend on. Recent iEEG foundation models learn by reconstructing or predicting their inputs, which leaves the retention of these characteristics implicit. They are also evaluated mainly on cognitive decoding and a narrow clinical task, i.e., seizure detection. On a broad, clinically relevant benchmark such as Omni-iEEG, they remain below task-specific models when used frozen. We introduce PHASE, a physiology-guided foundation model that makes these characteristics explicit learning targets, pairing them with masked latent prediction in a temporal stage (PHASE-T) within each channel and a spatiotemporal stage (PHASE-ST) across synchronized channels. PHASE is pretrained on heterogeneous recordings from 222 participants at nine clinical sites. On all five Omni-iEEG clinical tasks, frozen PHASE-T outperforms every evaluated foundation model by up to 31\%, and fine-tuned PHASE-T surpasses the task-specific models, setting a new state of the art. PHASE-T benefits from physiological supervision, outperforming variants trained with latent prediction alone or auxiliary waveform reconstruction on every task in matched ablations. PHASE-T generalizes to unseen institutions, outperforming the compared models with few or no local labels. PHASE-ST further improves seizure-onset-zone identification over PHASE-T and, when frozen, decodes sound volume and pitch on BrainTreebank better than published models. Beyond task performance, PHASE learns to encapsulate the physiological characteristics clinicians recognize, from seizure onset and its propagation to anatomical region identity, even though its pretraining contains no ictal recordings or anatomical labels.

0.08

Probing Spatial and Spectral Grounding in EEG Foundation Models

cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
similarity 0.65
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.

0.09