CS Paper Radar

DenoFlow: Flow Matching for SSVEP Denoising under Real Physiological Artifacts

Zhentao He, Ziwei Wang, Dongrui Wu

cs.LG ·submitted 2026-09-24 03:07 UTC · v1
code/data

Abstract

Electroencephalography (EEG)-based brain-computer interfaces (BCIs), particularly steady-state visual evoked potential (SSVEP) systems, are highly vulnerable to noise and artifacts, which severely degrade decoding accuracy. Although recent denoising approaches have shown promise, they are fitted without paired ground truth, can settle on reproducing their input, and are optimized on waveform distance alone, which says nothing about whether the output stays decodable. To address these issues, we propose DenoFlow, which casts SSVEP denoising as transport: instead of learning a direct map from a contaminated trial to a clean one, a field network regresses the velocity of the straight path between them, following the rectified-flow formulation, and denoising integrates that field forward from the observation. The field network is an encoder-decoder that sees the contaminated trial at every layer and the path position at its bottleneck, and a classifier trained alongside it supervises the integrated output. Because the observation itself is both the conditioning input and the starting point of the integration, the model never generates a trial from noise, and training reduces to regression, removing the adversarial min-max game. To obtain paired data on datasets with no ground truth, we injected physiological artifacts of the recorded electromyography (EMG) and electrooculography (EOG) signals under a controlled signal-to-noise target. Experiments on two public SSVEP datasets with five popular SSVEP decoders showed that DenoFlow outperformed seven baseline denoising models on both signal fidelity and downstream decoding accuracy. Code is available at https://github.com/wzwvv/DenoFlow.

Comment
14 pages, 6 figures

Closest papers

Nearest neighbours by meaning across the whole index.

iEEG Can Help EEG: Improving Clinical Scalp EEG Analysis through Intracranial Priors

cs.LG eess.SPq-bio.NC ·2026-11-16 ·Xianglong Bao, Yi Ding, Zengxiang Li, Nan Liu, Kewen Wang +2 more
top venuecode/data similarity 0.64
Abstract · Accepted at KDD 2027

Scalp electroencephalography (EEG) is a cornerstone of clinical brain monitoring, making the quality of its signal fundamental to downstream tasks and models. However, that signal is heavily contaminated by non-neural interference and blurred by volume conduction. Existing methods operate almost exclusively within the scalp modality, so they inherit the contamination they would need to overcome. In practice, intracranial EEG (iEEG) observes the neural activity with far higher fidelity, yet it is invasive and therefore scarce, and the two modalities are rarely recorded as pairs at scale, share no common channel space, and offer no clean ground truth to directly supervise a mapping. Motivated by the neuronal synchronization mechanism shared by the two modalities, we propose a reprogramming approach that fits a signal-to-signal model on iEEG alone and freezes it as a cross-modal prior. We introduce ReBrain, a framework to transfer an iEEG-learned prior to scalp EEG, which re-expresses any scalp signal through that prior and can be inserted upstream of any downstream model with no pairing or fine-tuning. ReBrain consistently improves host models across recordings from multiple hospitals and across architecture families, and our analysis traces this gain to genuine neural structure carried by iEEG rather than to the architecture itself. This work provides evidence that a scarce clean modality can serve as a transferable prior for an abundant noisy one, offering a general recipe for cross-modal transfer among biosignals. Our code is available at https://github.com/Xianglong-Bao/ReBrain.

0.72

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.63
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.31

Rethinking EEG Spatial Super-Resolution as Dynamic State Decomposition and Filtering

cs.AI cs.LG ·2026-10-17 ·Hongjun Liu, Leyu Zhou, Chang Ge, Shitong Duan, Chao Yao
similarity 0.62
Abstract

EEG spatial super-resolution aims to recover high-density neural signals from sparse electrode observations. Existing methods have achieved substantial progress through spatial modeling, generative reconstruction, and temporal representation learning. However, the current EEG state contains two different sources of information: predictable evolution inherited from preceding states and newly emerging changes revealed by the current observation. Most approaches typically do not model these two components explicitly. In this work, we formulate streaming EEG spatial super-resolution as a sequential state filtering problem and propose Dynamic State Filtering (DSF). Rather than relying on a single temporal reconstruction pathway, DSF combines a history-aware dynamical branch with an innovation-filtering branch that explicitly decomposes waveform-state estimation into prediction and observation-driven correction. To infer how spatially incomplete innovations should affect missing locations, DSF routes the observed innovations across electrodes through a mask-constrained, topology-aware transition operator and incorporates them through uncertainty-aware state correction. The two complementary estimates are finally fused to reconstruct the dense EEG signal. Experiments on SEED, SEED-IV and BCI2000 demonstrate that DSF improves reconstruction fidelity and downstream utility while maintaining robustness under dynamically changing and unreliable sparse observations.

0.14

E2I-Flow: EEG-to-Image Reconstruction via Wavelet-Temporal Cross-Attention and Conditional Flow Matching

cs.CV cs.LG ·2026-11-03 ·Haowei Pan, Hwa Hui Tew, Junn Yong Loo, Fuad Noman, Hernando Ombao +1 more
similarity 0.60
Abstract

Electroencephalography (EEG)-based visual decoding and reconstruction aims to recover visual information from non-invasive brain signals. But there are challenges due to the complex temporal-frequency characteristics of EEG signals and the difficulty of discrete denoising framework in mapping neural activity to meaningful visual representations. Here, we propose E2I-Flow, an EEG-to-image decoding and reconstruction framework that combines a novel EEG encoder for time-frequency representation learning from EEG features, and conditional flow matching for visual decoding. A stationary-wavelet frequency branch and a temporal-mixing branch are integrated through bidirectional cross-attention and adaptive fusion, with the resulting EEG representations aligned to ground-truth image embeddings using contrastive and mean-squared-error loss supervisions. The aligned EEG representation is then used as a condition for a Transformer-based flow-matching model to predict the corresponding visual embedding for image synthesis. Experimental results show strong zero-shot EEG-to-image retrieval and improved visual reconstruction performance, outperforming several state-of-the-art baselines.

0.25

TriRouter: Sparse-to-Dense Electrode-Space Routing for Robust EEG Motor Imagery Decoding

cs.LG eess.SP ·2026-10-16 ·Ying Zhou, Yaoxin, Mengting Liu
similarity 0.60
Abstract · Submitted to IEEE ICASSP 2027

Motor imagery brain-computer interfaces require reliable decoding from multichannel EEG, but practical acquisition often yields sparse or corrupted electrode montages. We propose TriRouter, an electrode-space routing framework with discriminative-preservation, mask-robustness, and latent-compensation paths. A validation-calibrated router uses observable channel availability to allocate path contributions, preserving complete-channel discrimination while increasing representation recovery under severe missingness. In BNCI2014-001, TriRouter outperforms standard public backbones and a dynamic-spatial-filtering corrupted-EEG baseline. It improves accuracy over the strongest corrupted-EEG baseline by 3.68, 4.02, and 6.46 percentage points at nominal 25%, 50%, and 75% missing settings, and remains effective under structured regional missingness and additional low-channel dataset evaluation.

0.17

Observable And Null Space Electrophysiological Source Imaging with Diffusion Priors

cs.CE ·2026-10-20 ·Zirui Wen, Shihao Yang, Feng Liu
similarity 0.60
Abstract

Electrophysiological source imaging is severely underdetermined because the lead-field matrix has limited rank relative to the source dimension and strongly correlated columns. Scalp EEG measurements constrain only the observable row-space component, leaving a high-dimensional null space unobservable. We propose a two-stage framework coupling posterior diffusion refinement with deterministic null-space completion. A minimum-norm-initialized, singular-coordinate Posterior-DDIM sampler combines a spatiotemporal diffusion prior with direction-dependent measurement reliability to refine the observable component. A frozen ridge predictor and nonlinear temporal residual network then estimate the null component under explicit projection constraints, preserving the refined row estimate and its predicted EEG exactly. All learned components are trained exclusively on simulated cortical activity and its row-null decomposition, without paired EEG-source training data. Across simulations with varying noise levels, the method achieved higher frame-level area under the receiver operating characteristic curve and average precision, together with lower localization error, than conventional and learning-based baselines. Exploratory evaluations on evoked EEG and simultaneous scalp EEG-stereo-EEG recordings showed condition- and event-dependent concordance with cross-modal and intracranial references.

0.11

SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising

eess.SP ·2026-09-10 ·Cheng-Han Shih, Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Yu Tsao
published similarity 0.59
Abstract · 6 pages, 3 figures, 2 tables. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society …

Electrocardiogram (ECG) artifact contamination frequently occurs in surface electromyography (sEMG) when muscles are recorded near the heart. Existing neural network (NN)-based approaches typically perform waveform-level end-to-end denoising with pointwise losses, but often fail to preserve the spectral structures of sEMG. In addition, these models do not exploit the prior knowledge that ECG mainly distorts the low-frequency band of sEMG. We propose SSEMG-Net, a spectrogram-domain model that explicitly captures sEMG-ECG interactions using a bidirectional Mamba backbone and a dual-head decoder for magnitude masking and wrapped-phase estimation. The magnitude masking module is physiologically aware, restricting denoising to the low-frequency sub-band where ECG activity predominates. Experimental results demonstrate that SSEMG-Net achieves superior signal quality and lower feature-extraction error compared to prior methods, underscoring its potential for clinical applications where preserving sEMG spectral features is essential.

0.44

Sensor Geometry as a Flow-Matching Prior for Multi-Channel Brain Signals

cs.LG cs.AI ·2026-10-06 ·Jaedong Hwang
similarity 0.58
Abstract

Flow-matching models start from an isotropic Gaussian source, the standard choice when the correlation structure of the data is unknown in advance. For multi-channel brain recordings, however, part of this structure is known in advance. Electrodes sit at fixed positions on the head, and volume conduction through the skull and scalp makes nearby electrodes co-vary in a way that is shared across subjects. Existing EEG generative models nonetheless leave the network to learn this from scratch. We put this structure into the source instead. From the sensor coordinates alone, we build a k-nearest-neighbor graph and take a graph-Matérn function of its Laplacian as the source covariance, so the flow starts from spatially coherent patterns rather than channel-independent noise. The change adds no learned parameters, works with any coupling and any drift network, and uses the same three hyperparameters on every dataset. Across eight EEG datasets and four flow-matching methods, the graph-Matérn source lowers the spectral discrepancy between generated and real signals in the five clinical bands (PSD-KL) on most datasets. PSD-KL falls by 12% to 17% in geometric mean over datasets depending on the method and by up to 40% on PhysioNet-MI, the densest montage. We show that the improvement stems from the spatial eigenvectors of the local graph of sensor positions, since randomizing the eigenvectors while preserving the eigenvalue spectrum eliminates the gain. Furthermore, a prior fitted directly to the empirical data covariance performs worse than isotropic noise. The same construction applies unchanged to MEG, intracranial EEG with patient-specific grids, and a traffic-sensor network, lowering PSD-KL for every method on each. https://jd730.github.io/projects/GraphPrior

0.33