CS Paper Radar

Rethinking EEG Spatial Super-Resolution as Dynamic State Decomposition and Filtering

Hongjun Liu, Leyu Zhou, Chang Ge, Shitong Duan, Chao Yao

cs.AI cs.LG ·submitted 2026-10-17 07:41 UTC · v1

Abstract

EEG spatial super-resolution aims to recover high-density neural signals from sparse electrode observations. Existing methods have achieved substantial progress through spatial modeling, generative reconstruction, and temporal representation learning. However, the current EEG state contains two different sources of information: predictable evolution inherited from preceding states and newly emerging changes revealed by the current observation. Most approaches typically do not model these two components explicitly. In this work, we formulate streaming EEG spatial super-resolution as a sequential state filtering problem and propose Dynamic State Filtering (DSF). Rather than relying on a single temporal reconstruction pathway, DSF combines a history-aware dynamical branch with an innovation-filtering branch that explicitly decomposes waveform-state estimation into prediction and observation-driven correction. To infer how spatially incomplete innovations should affect missing locations, DSF routes the observed innovations across electrodes through a mask-constrained, topology-aware transition operator and incorporates them through uncertainty-aware state correction. The two complementary estimates are finally fused to reconstruct the dense EEG signal. Experiments on SEED, SEED-IV and BCI2000 demonstrate that DSF improves reconstruction fidelity and downstream utility while maintaining robustness under dynamically changing and unreliable sparse observations.

Closest papers

Nearest neighbours by meaning across the whole index.

Decoupling Time and Space: A Temporally Conditioned Refinement for EEG Source Imaging

cs.LG ·2026-10-05 ·Marco Morik, Jesse Palarus, Carmen Vidaurre, Klaus-Robert Müller, Shinichi Nakajima
similarity 0.67
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Electroencephalography (EEG) offers millisecond temporal resolution, but inferring underlying neural sources is a severely ill-posed spatial inverse problem. While deep learning has advanced spatial reconstruction, current architectures face a critical dilemma: frame-by-frame models discard vital temporal context, whereas full 4D spatiotemporal networks introduce an architectural trade-off between reconstruction accuracy and inference cost. We propose a novel two-stream framework that explicitly decouples global temporal representation learning from per-time-point spatial refinement. A Transformer-based Temporal Condition Encoder processes the entire EEG sequence via factorized spatiotemporal attention, retaining sensor-resolved features. A fixed inverse then maps these features into source-indexed conditioning for a per-timestep Source-Space Transformer or volumetric convolutional refiner. Extensive evaluations on realistic synthetic data demonstrate that this temporal prior dramatically improves spatial localization, outperforming classical and spatiotemporal baselines, particularly in high-noise and multi-source regimes. Training across diverse leadfields and explicit operator mismatches improves transfer to unseen head geometries and brings template-based reconstruction closer to subject-specific inversion. Furthermore, we apply the model trained only on synthetic EEG data to real-world EEG. A logistic regressor fit on source power differences in eyes-open, eyes-closed conditions successfully decodes age groups.

0.25

NeurDuo-EEG: A Long-Sequence EEG Foundation Model with Persistent State and Explicit Memory

cs.LG ·2026-09-29 ·Yifan Wang, Haiping Liu, Yang Cui, Wenhao Cai, Shuhang Li +11 more
code/data similarity 0.66
Abstract

Electroencephalography (EEG) is recorded continuously over hours, with relevant dynamics spanning timescales from milliseconds to hours. Most EEG foundation models nevertheless process fixed windows independently, limiting their ability to capture information encoded in long-timescale dynamics. State-space architectures enable persistent recurrent processing, but long-range information remains implicitly compressed in recurrent states. We present NeurDuo-EEG, a causal EEG foundation model with channel-resolved persistent memory. NeurDuo-EEG introduces multi-timescale memory management with learned consolidation and selective retrieval, enabling persistent modelling of continuous EEG with fixed-size state. It is pre-trained on 3,955 hours of EEG from 17 public datasets using multichannel autoregressive prediction of discrete spectral codes. Across three short-window and two long-sequence downstream tasks, NeurDuo-EEG achieves the best performance on four of five benchmarks, including all three short-window tasks and seizure detection, where AUC-PR improves from $0.285$ to $0.471$ over the strongest non-NeurDuo baseline. NeurDuo-EEG also remains competitive on sleep staging and supports efficient streaming inference, with nearly constant per-chunk latency as the available history grows to one hour. Notably, the Small variant achieves this with only 4.7M backbone parameters. These results demonstrate the value of persistent, multi-timescale modelling for both long-sequence and short-window EEG analysis. Our code is available at https://github.com/YifaNNW/NeurDuo-EEG.

0.30

HP-GSBS: Accelerating greedy state boundary search with reusable interval statistics

cs.CE q-bio.NC ·2026-10-19 ·Yanzhe Zhao, Yongzhang Ji
code/data similarity 0.65
Abstract

Greedy State Boundary Search (GSBS) identifies transitions between relatively stable neural activity patterns in continuous recordings. Repeated template reconstruction and correlation evaluation make analyses across recordings and parameter settings computationally expensive. We present HP-GSBS, an open-source implementation that expresses the matching objective as additive interval contributions and computes t-distance from reusable correlation statistics. Streaming candidate reduction, sequential local refinement, and active-block reuse complement CPU, PyTorch CUDA, and Triton execution paths. Across seven controlled workloads with two input realizations each, median same-input speedups range from 154 to 1,730. All 168 optimized executions reproduce complete reference boundary histories and selected state counts, with a maximum absolute t-distance difference of $1.88\times10^{-11}$. Four publicly supplied BBBD EEG analysis matrices provide complementary cross-backend validation. A naturalistic fMRI application segments 4,230 angular-gyrus voxels in a group response and 16 participants; the 17 CPU fits total 213.10 seconds. Mean pairwise boundary alignment exceeds a circular-shift baseline, illustrating cohort-level use of the saved segmentations. Versioned results, recording-level parallelism, and optional low-memory execution support varied analysis scales. HP-GSBS connects an explicit mathematical reformulation of repeated computation to efficient and reproducible neural-state analysis.

0.21

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

cs.LG eess.SP ·2026-10-05 ·Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero
benchmark similarity 0.63
Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

0.20

EEG-PRISM: Physiologically-Grounded Interpretability of Predictions by EEG Foundation Models

cs.LG ·2026-08-13 ·Deeksha M Shama, Punnisa Amornsirikul, Archana Venkataraman
similarity 0.62
Abstract

Objective: Foundation models represent the next advancement in AI for EEG analysis; however current explainable AI techniques provide attribution scores in the time-channel input space, which is mismatched to clinical intuition about EEG. Thus, there is a critical need for a universal method that can extend the interpretability of any foundation model to alternative and physiologically relevant domains without modifying or retraining the underlying model. Methods: EEG-PRISM leverages linear transformations and established backpropagation rules to map time-channel attribution scores into alternative domains. We derive mappings to the frequency domain via an invertible DFT and to the source domain via an approximately invertible EEG generative model. We evaluate EEG-PRISM in simulated and real data, assessing recovery of ground-truth phenomena across domains with five foundation models and four AI explainers. Results: In simulation, EEG-PRISM achieves near-perfect spectral recovery and 69.2% spatial accuracy. In epilepsy, EEG-PRISM correctly determines that delta-theta activity is most salient and correctly localizes the seizure onset region with 50% accuracy. In autism, EEG-PRISM localizes the predictive delta-alpha biomarkers to frontal and temporal regions, consistent with prior work. Conclusion: EEG-PRISM is a theoretically-grounded post-hoc attribution method with accurate mapping into the spectral and spatial domains. It supports window-level analysis of transient events (e.g., seizures) and group-level identification of clinically relevant biomarkers (e.g., autism), thus advancing interpretable EEG foundation models. Significance: This work enables physiologically-grounded interpretation of EEG foundation models and supports clinically relevant insights such as event localization and biomarker identification.

0.04

PHASE: A Physiology-Guided Hierarchical Foundation Model for Intracranial EEG

cs.LG cs.AI ·2026-09-28 ·Yipeng Zhang, Chenda Duan, Yuanyi Ding, Tianyi Wang, Atsuro Daida +8 more
benchmark similarity 0.62
Abstract · Author Metadata Correction

Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristics, which carry much of the information that downstream tasks depend on. Recent iEEG foundation models learn by reconstructing or predicting their inputs, which leaves the retention of these characteristics implicit. They are also evaluated mainly on cognitive decoding and a narrow clinical task, i.e., seizure detection. On a broad, clinically relevant benchmark such as Omni-iEEG, they remain below task-specific models when used frozen. We introduce PHASE, a physiology-guided foundation model that makes these characteristics explicit learning targets, pairing them with masked latent prediction in a temporal stage (PHASE-T) within each channel and a spatiotemporal stage (PHASE-ST) across synchronized channels. PHASE is pretrained on heterogeneous recordings from 222 participants at nine clinical sites. On all five Omni-iEEG clinical tasks, frozen PHASE-T outperforms every evaluated foundation model by up to 31\%, and fine-tuned PHASE-T surpasses the task-specific models, setting a new state of the art. PHASE-T benefits from physiological supervision, outperforming variants trained with latent prediction alone or auxiliary waveform reconstruction on every task in matched ablations. PHASE-T generalizes to unseen institutions, outperforming the compared models with few or no local labels. PHASE-ST further improves seizure-onset-zone identification over PHASE-T and, when frozen, decodes sound volume and pitch on BrainTreebank better than published models. Beyond task performance, PHASE learns to encapsulate the physiological characteristics clinicians recognize, from seizure onset and its propagation to anatomical region identity, even though its pretraining contains no ictal recordings or anatomical labels.

0.08

DenoFlow: Flow Matching for SSVEP Denoising under Real Physiological Artifacts

cs.LG ·2026-09-24 ·Zhentao He, Ziwei Wang, Dongrui Wu
code/data similarity 0.62
Abstract · 14 pages, 6 figures

Electroencephalography (EEG)-based brain-computer interfaces (BCIs), particularly steady-state visual evoked potential (SSVEP) systems, are highly vulnerable to noise and artifacts, which severely degrade decoding accuracy. Although recent denoising approaches have shown promise, they are fitted without paired ground truth, can settle on reproducing their input, and are optimized on waveform distance alone, which says nothing about whether the output stays decodable. To address these issues, we propose DenoFlow, which casts SSVEP denoising as transport: instead of learning a direct map from a contaminated trial to a clean one, a field network regresses the velocity of the straight path between them, following the rectified-flow formulation, and denoising integrates that field forward from the observation. The field network is an encoder-decoder that sees the contaminated trial at every layer and the path position at its bottleneck, and a classifier trained alongside it supervises the integrated output. Because the observation itself is both the conditioning input and the starting point of the integration, the model never generates a trial from noise, and training reduces to regression, removing the adversarial min-max game. To obtain paired data on datasets with no ground truth, we injected physiological artifacts of the recorded electromyography (EMG) and electrooculography (EOG) signals under a controlled signal-to-noise target. Experiments on two public SSVEP datasets with five popular SSVEP decoders showed that DenoFlow outperformed seven baseline denoising models on both signal fidelity and downstream decoding accuracy. Code is available at https://github.com/wzwvv/DenoFlow.

0.37

Neural State Prediction: Obstructing Shortcut Learning in EEG Foundation Models

cs.AI ·2026-09-25 ·Kieren Yu, Ziyang Liu, Chang Huang, Jintai Chen, Kaishun Wu
similarity 0.61
Abstract

EEG foundation models increasingly use masked prediction to learn from unlabeled recordings, but optimizing this objective does not ensure transferable neural representations. A central challenge is that stable positional cues and local correlations can make masked regions predictable without integrating distributed neural context. To reduce this reliance on low-information prediction paths, we introduce Neural State Prediction (NSP), a latent-predictive framework that constrains both the prediction target and the available context. NSP uses a Target Encoder updated by an exponential moving average (EMA) to define latent supervision. Identity residualization removes additive effects associated with channel identity and relative time from the targets, while topology-separated context excludes their immediate spatial and temporal neighborhood from the visible input. We pretrain NSP on 2.2 million EEG segments from TUEG and evaluate it across 30 downstream datasets spanning clinical diagnosis, sleep staging, emotion recognition, motor imagery, event-related potentials, cognitive-state decoding, and language retrieval. Under full-parameter multi-task fine-tuning on EEG-FM-Bench, NSP achieves 63.94 macro balanced accuracy across 14 datasets, exceeding the strongest evaluated baseline by 2.35 percentage points. Controlled component ablations assess the contribution of each mechanism, while matched context controls and held-out interventions characterize the role of context geometry, signal content, and positional information. Jointly designing latent targets and their context offers a promising direction for EEG foundation models that learn from distributed signal structure.

0.21