CS Paper Radar

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero

cs.LG eess.SP ·submitted 2026-10-05 21:29 UTC · v1
benchmark

Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

Closest papers

Nearest neighbours by meaning across the whole index.

Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

cs.LG eess.SP ·2026-10-21 ·Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou
top venue similarity 0.72
Abstract · Accepted for publication in IEEE Transactions on Instrumentation and Measurement (TIM), 2026

Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsistency. Existing adaptation methods remain impractical for real-time measurement scenarios, as they typically require offline access to source or aggregated target data. To address these challenges, this article proposes memory-augmented online test-time adaptation (OTTA) with perturbation consistency and confidence calibration (MOPC), a source-free framework designed to enhance the reliability of BCI instrumentation. MOPC enables the measurement system to update its decoding parameters on the fly during the inference stage, facilitating single-pass adaptation without accessing sensitive source data. We introduce random-mask perturbations to enforce prediction consistency against inherent EEG signal noise and acquisition artifacts. Furthermore, a confidence-calibrated reweighting loss is designed to integrate feature-space similarity, effectively mitigating unreliable pseudolabels and class imbalance during continuous signal acquisition. To ensure system stability and prevent the catastrophic forgetting of established neural patterns, a lightweight memory module is incorporated to regularize parameter updates within a tight latency budget. Evaluated on the BCI IV IIb and OpenBMI datasets, MOPC achieves state-of-the-art performance, outperforming prior methods by 2.22~\% and 3.67~\%, respectively, while keeping the per-trial adaptation latency to approximately 40--60 ms. This study provides a robust, recalibration-free solution for real-time EEG decoding, marking a significant advancement in the precision and usability of practical BCI measurement instruments.

0.22

GALA: Gallery-Level Alignment for Real-Life Vision Decoding from EEG

cs.AI cs.LG ·2026-11-18 ·Philippe Forest, Giulia Lioi, Mai Pham Quyen, Alix Lamouroux, Javen Shi +1 more
benchmark similarity 0.71
Abstract

Neural decoding of visual experience from electroencephalography (EEG) has achieved strong performance in intra-subject settings, but current methods fail to generalize across individuals: on the standard 200-way benchmark THINGS-EEG-2, top-1 accuracy drops from above 80% within subjects to about 32% for an unseen subject. Adapting a pre-trained encoder to new subjects and sessions typically requires labeled data, a bottleneck whose collection time severely limits practical device deployment. In a practical Brain-Computer Interface (BCI), however, the possible outcomes are known in advance and form a gallery of candidates, and the unlabeled EEG of the user accumulates as soon as the device is used. We propose a new setting, incremental transductive calibration, in which the decoder is calibrated regularly on all the unlabeled EEG received so far and on the known gallery, without any labels. This setting is closer to the conditions of a deployed BCI than the zero-shot and batch evaluations in current use. We evaluate it with a protocol in which queries arrive one at a time, with unknown and possibly unequal frequencies, and each query is decoded before it is used for calibration. In this setting, we introduce GALA : GAllery-Level Alignment, a label-free calibration method which registers the unlabeled EEG embeddings onto the gallery through shrinkage whitening, hubness correction and a Sinkhorn--Procrustes alignment with query frequencies estimated from the buffer, updated after every query. On THINGS-EEG-2, with a gallery of 200 images, it raises the top-1 accuracy on a new subject from 28% to 67% over 53 minutes of use. Across 60 evaluation settings that vary the gallery size, the query frequencies and the number of repetitions averaged per query, GALA is the most accurate label-free method in every setting, 6.6 points above the best competing method on average at the end of the stream.

0.27

CortexBridge: Cortical Alignment of EEG Montages for Foundation Models

cs.AI eess.SP ·2026-10-01 ·Jiazhen Hong, Xiaotian Zhou, Zihao Ding, Kailong Wang, Yu Wu
similarity 0.68
Abstract

Electroencephalography (EEG) foundation models are often pretrained with a fixed channel vocabulary or a limited set of montages, making transfer difficult when electrode layouts change. We propose CortexBridge, a lightweight adapter that combines EEG features with electrode and atlas coordinates to map arbitrary montages into a shared cortical latent space. Evaluated with three frozen foundation models on five brain-computer interface (BCI) datasets from the Mother of All BCI Benchmarks (MOABB), CortexBridge improves performance in 13 of 15 evaluations. The gains in balanced accuracy average 0.80% for EEGPT, 0.70% for LaBraM, and 3.26% for CBraMod, with a maximum gain of 13.02% on 12-class steady-state visual evoked potential (SSVEP) classification. Visualizations of the learned atlas representations reveal task-dependent spatial patterns, with SSVEP showing a more concentrated representation in the Yeo Visual network than auditory P300. These results establish cortical alignment as a learnable and anatomically grounded routing mechanism from heterogeneous EEG montages to pretrained foundation models.

0.39

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.68
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.68
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.67
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Parameter-Efficient Self-Supervised Adaptation for EEG-FM under Fixed Computational Budgets

cs.LG cs.AI ·2026-08-25 ·Meghal Dani, Stefanie Liebe
top venuecode/data similarity 0.66
Abstract

EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tuning is impractical for resource-constrained clinical settings due to high computational requirements. In this work, we investigate whether parameter-efficient self-supervised adaptation, updating only 9% of parameters suffices to align representations to target tasks. We evaluate our method on two state-of-the-art models with different pretraining objectives: BIOT (contrastive) and CBraMod (masked reconstruction), and evaluate on three clinical EEG datasets for abnormality detection (TUAB), event classification (TUEV), and seizure detection (CHB-MIT) under both in-distribution and out-of-distribution conditions. SSL adaptation yields consistent gains over linear probing, up to 20x AUCPR. Under a fixed compute budget, peak performance requires only 20--50% of available unlabeled data. Critically, when total window count is fixed, performance remains invariant to patient count, suggesting that performance is dependent on overall temporal window diversity only. Our findings demonstrate that parameter-efficient adaptation enables effective deployment of EEG Foundation models (EEG-FM) with minimal computational overhead and data collection burden. Code available at: https://github.com/c3n-group/efficient-eeg-adapt

0.54

Nimbus Studio reproduces reference BCI decoding pipelines: a validation study on public benchmarks across protocols and paradigms

cs.HC ·2026-10-09 ·Sergey Musienko
benchmark similarity 0.65
Abstract · 6 pages. Platform: https://studio.nimbusbci.com/

Nimbus Studio is a visual pipeline platform for brain-computer interface (BCI) experiments: researchers assemble preprocessing, feature extraction, decoding, and evaluation over public benchmark datasets or their own recordings, with cross-validated evaluation protocols (including leave-one-subject-out), BIDS export, and bring-your-own Python model classes. Whether its numbers can be trusted is a fair question for any such platform. We answer it with a parity study: six standard BCI decoding pipelines (CSP+LDA, Riemannian MDM, tangent-space logistic regression through the platform's bring-your-own-code node, P300 xDAWN+LDA, and the deep ShallowConvNet and EEGNet) were evaluated on three public datasets (motor-imagery BNCI-2014-001/004; P300 BNCI-2014-009) under two protocols (per-subject session holdout and pooled leave-one-subject-out cross-validation via the platform's planned-CV driver), once through Nimbus Studio's execution engine and once through independent, hand-written reference implementations built directly on MNE-Python, scikit-learn, pyriemann, and braindecode. Every deterministic pipeline matched the reference exactly (0.00 points maximum difference across all 54 session-holdout subject-runs and all CSP/MDM grouped-CV folds), including pipelines through the bring-your-own-code node and the CV orchestration; the remaining grouped-CV cells agree to floating-point precision (worst case 0.06 points, about one trial per fold). The stochastic deep models agreed within seed-to-seed training variability, estimated with multi-seed reruns on each side. The platform's execution engine therefore computes the same science as the reference stack across protocols, paradigms, and extensibility surfaces. The platform is available at https://studio.nimbusbci.com/, and the complete harness and per-subject results accompany this paper for independent verification.

0.15