Electroencephalography (EEG) foundation models are often pretrained with a fixed channel vocabulary or a limited set of montages, making transfer difficult when electrode layouts change. We propose CortexBridge, a lightweight adapter that combines EEG features with electrode and atlas coordinates to map arbitrary montages into a shared cortical latent space. Evaluated with three frozen foundation models on five brain-computer interface (BCI) datasets from the Mother of All BCI Benchmarks (MOABB), CortexBridge improves performance in 13 of 15 evaluations. The gains in balanced accuracy average 0.80% for EEGPT, 0.70% for LaBraM, and 3.26% for CBraMod, with a maximum gain of 13.02% on 12-class steady-state visual evoked potential (SSVEP) classification. Visualizations of the learned atlas representations reveal task-dependent spatial patterns, with SSVEP showing a more concentrated representation in the Yeo Visual network than auditory P300. These results establish cortical alignment as a learnable and anatomically grounded routing mechanism from heterogeneous EEG montages to pretrained foundation models.

Closest papers

Nearest neighbours by meaning across the whole index.

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

cs.LG eess.SP ·2026-10-05 ·Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero
benchmark similarity 0.68
Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

0.20

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.68
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

Probing Spatial and Spectral Grounding in EEG Foundation Models

cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
similarity 0.68
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.

0.09

Representational and Functional Robustness to Electrode Montages in EEG Foundation Models

cs.LG ·2026-09-28 ·Jakob Steglich, Justus Meyer zu Bexten, Shakiba Moradi, Laure Ciernik, Simon M. Hofmann +1 more
similarity 0.67
Abstract · 17 pages, 9 figures

EEG foundation models (EEG-FMs) are intended to generalize across different datasets by learning representations that, ideally, are invariant to dataset-specific EEG configurations such as electrode montages. However, EEG-FMs that accept different montages as input do not guarantee that representations and predictions remain stable across different electrode configurations, especially outside the training setting. In this work, we investigate the effects of different electrode montages through a joint functional and representational analysis of four EEG foundation models selected to span distinct montage-handling designs. We evaluate embeddings on cross-subject resting-state eyes-open/closed and within-subject motor-imagery classification under spatially informed channel reduction. Functional robustness is tested through the generalizability of linear probes across channel counts, while representational robustness is assessed through within-subject similarity and preservation of between-subject geometry. The four models show distinct robustness profiles, and the two axes dissociate: large changes in embedding similarity need not come with comparable probe degradation, and stable embeddings can still lose downstream performance. Comparing two readouts of the same encoder further shows that aggregation, not the encoder alone, determines functional robustness: pooling into anatomically aligned regions degrades less than a learned global readout, despite being montage-invariant by construction. Montage robustness is therefore a joint property of the encoder and its aggregation, and characterizing it requires both a representational and a functional axis. Input compatibility alone is evidence for neither.

0.44

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

cs.LG cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
position similarity 0.66
Abstract · Preprint. Under review

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.

0.21

ProtoEEG: Structured Prototype Alignment for EEG Visual Decoding

cs.CV cs.AIcs.LG ·2026-10-20 ·Kieren Yu, Chang Huang, Ziyang Liu, Kaishun Wu
similarity 0.66
Abstract

EEG visual decoding remains difficult because scalp recordings are noisy, spatially coarse, and variable across trials and subjects. Most systems align each trial with a dense image embedding, although that embedding mixes semantic content with instance-specific texture, pose, and background. This target can demand details absent from EEG and provides no explicit account of the visual factors supporting a prediction. We propose \textbf{ProtoEEG}, a prototype-mediated framework that reformulates EEG--image alignment as soft composition over a shared learnable visual codebook. A trainable EEG encoder and a frozen visual teacher produce assignment distributions over the same $K=64$ prototypes. Their weighted reconstructions form a structured representation for retrieval and image generation. Prototype contrast supplies the main cross-modal training signal, distribution alignment coordinates codebook use across modalities, an instance anchor preserves fine-grained discrimination, and diversity regularization prevents redundant prototypes. The shared assignment profile also makes the learned bottleneck directly testable through prototype retention, random selection, and identity shuffling. Across five seeds, ProtoEEG reaches 64.0\% Top-1 and 91.5\% Top-5 on THINGS-EEG2 200-way retrieval. After retraining on EEG-ImageNet, it obtains 44.8\% Top-1 and 73.8\% Top-5 in 80-way retrieval. ProtoEEG also ranks first on all seven reconstruction metrics. Removing prototype contrast lowers Top-1 by 56.9 percentage points, while shuffling prototype identities reduces it to 0.5\%. Prototype analyses further show distributed assignments and broad codebook use rather than one-prototype routing. These results support structured alignment targets as a practical alternative to increasing encoder or teacher capacity alone.

0.14

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.66
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

The Platonic Brain: Representational Convergence in EEG Foundation Models

cs.AI ·2026-11-03 ·Nicolas Waehner, Enzo Tagliazucchi, Jacobo Sitt, Demian Wassermann, Giovanni Franco Gabriel Marraffini +1 more
similarity 0.66
Abstract

The Platonic Representation Hypothesis (PRH) predicts that artificial neural networks converge on shared representations as scale and performance increase. We test whether these predictions hold for representations of the human brain with EEG foundation models. Using EEG recordings from six participants watching a television series, together with aligned visual and language content, we tested whether EEG foundation-model representations converge within and across modalities as their embeddings become better at decoding an informative set of EEG markers. We found that EEG models with greater decodability showed stronger cross-family alignment in both local neighbourhood similarity and global structure, not consistently increasing with model parameter count. Cross-modal convergence was modality and metric dependent: greater EEG decodability was associated with stronger global alignment to language, but not consistently to vision models, while local alignment showed no consistent association. This dissociation may reflect local sensitivity to low-level sensory features, whereas global geometry may capture weaker shared semantic structure.