CS Paper Radar

Probing Spatial and Spectral Grounding in EEG Foundation Models

Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou

cs.NE ·submitted 2026-10-21 07:57 UTC · v1

Abstract

EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.

Comment
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Closest papers

Nearest neighbours by meaning across the whole index.

EEG-PRISM: Physiologically-Grounded Interpretability of Predictions by EEG Foundation Models

cs.LG ·2026-08-13 ·Deeksha M Shama, Punnisa Amornsirikul, Archana Venkataraman
similarity 0.74
Abstract

Objective: Foundation models represent the next advancement in AI for EEG analysis; however current explainable AI techniques provide attribution scores in the time-channel input space, which is mismatched to clinical intuition about EEG. Thus, there is a critical need for a universal method that can extend the interpretability of any foundation model to alternative and physiologically relevant domains without modifying or retraining the underlying model. Methods: EEG-PRISM leverages linear transformations and established backpropagation rules to map time-channel attribution scores into alternative domains. We derive mappings to the frequency domain via an invertible DFT and to the source domain via an approximately invertible EEG generative model. We evaluate EEG-PRISM in simulated and real data, assessing recovery of ground-truth phenomena across domains with five foundation models and four AI explainers. Results: In simulation, EEG-PRISM achieves near-perfect spectral recovery and 69.2% spatial accuracy. In epilepsy, EEG-PRISM correctly determines that delta-theta activity is most salient and correctly localizes the seizure onset region with 50% accuracy. In autism, EEG-PRISM localizes the predictive delta-alpha biomarkers to frontal and temporal regions, consistent with prior work. Conclusion: EEG-PRISM is a theoretically-grounded post-hoc attribution method with accurate mapping into the spectral and spatial domains. It supports window-level analysis of transient events (e.g., seizures) and group-level identification of clinically relevant biomarkers (e.g., autism), thus advancing interpretable EEG foundation models. Significance: This work enables physiologically-grounded interpretation of EEG foundation models and supports clinically relevant insights such as event localization and biomarker identification.

0.04

Representational and Functional Robustness to Electrode Montages in EEG Foundation Models

cs.LG ·2026-09-28 ·Jakob Steglich, Justus Meyer zu Bexten, Shakiba Moradi, Laure Ciernik, Simon M. Hofmann +1 more
similarity 0.73
Abstract · 17 pages, 9 figures

EEG foundation models (EEG-FMs) are intended to generalize across different datasets by learning representations that, ideally, are invariant to dataset-specific EEG configurations such as electrode montages. However, EEG-FMs that accept different montages as input do not guarantee that representations and predictions remain stable across different electrode configurations, especially outside the training setting. In this work, we investigate the effects of different electrode montages through a joint functional and representational analysis of four EEG foundation models selected to span distinct montage-handling designs. We evaluate embeddings on cross-subject resting-state eyes-open/closed and within-subject motor-imagery classification under spatially informed channel reduction. Functional robustness is tested through the generalizability of linear probes across channel counts, while representational robustness is assessed through within-subject similarity and preservation of between-subject geometry. The four models show distinct robustness profiles, and the two axes dissociate: large changes in embedding similarity need not come with comparable probe degradation, and stable embeddings can still lose downstream performance. Comparing two readouts of the same encoder further shows that aggregation, not the encoder alone, determines functional robustness: pooling into anatomically aligned regions degrades less than a learned global readout, despite being montage-invariant by construction. Montage robustness is therefore a joint property of the encoder and its aggregation, and characterizing it requires both a representational and a functional axis. Input compatibility alone is evidence for neither.

0.44

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.69
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.68
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

cs.LG cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
position similarity 0.68
Abstract · Preprint. Under review

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.

0.21

Quantifying Trait-State Hierarchy in EEG Foundation Model and Signal Processing Embeddings

cs.AI cs.LG ·2026-11-03 ·Anusha Madapura, Aditya Kommineni, Shrikanth Narayanan
similarity 0.68
Abstract

Electroencephalography (EEG) measures brain activity through recording electrical potentials of the scalp. EEG recordings capture two distinct sets of characteristics in the signal: (1) \emph{Traits} -- information that remains relatively constant over the course of a recording session, such as subject identity, age, and sex; (2) \emph{States} -- signatures that encode responses to external stimuli, including visual, auditory, and motor information. There is limited understanding of how different EEG modeling features (signal processing and foundation models) encode state and trait characteristics. In this work, we quantify state- and trait-level features captured by EEG embeddings using a hierarchy metric and kNN purity on Brain-Computer Interface dataset trials, and find that a majority of EEG features form a macro-trait hierarchy (embeddings form trait-level clusters with micro-states within). Our linear probe results indicate that this hierarchy structure leads to suboptimal state distinguishability, negatively impacting BCI performance of EEG foundation models. To mitigate this, we explore normalization techniques that reduce trait-specific information in embeddings and provide a $\sim$ 10\% improvement in balanced accuracy for state classification. Additionally, we observe that when fine-tuning models for downstream state decoding, embedding spaces transform from macro-trait to macro-state hierarchies, which in turn lead to better state decoding.

0.13

CortexBridge: Cortical Alignment of EEG Montages for Foundation Models

cs.AI eess.SP ·2026-10-01 ·Jiazhen Hong, Xiaotian Zhou, Zihao Ding, Kailong Wang, Yu Wu
similarity 0.68
Abstract

Electroencephalography (EEG) foundation models are often pretrained with a fixed channel vocabulary or a limited set of montages, making transfer difficult when electrode layouts change. We propose CortexBridge, a lightweight adapter that combines EEG features with electrode and atlas coordinates to map arbitrary montages into a shared cortical latent space. Evaluated with three frozen foundation models on five brain-computer interface (BCI) datasets from the Mother of All BCI Benchmarks (MOABB), CortexBridge improves performance in 13 of 15 evaluations. The gains in balanced accuracy average 0.80% for EEGPT, 0.70% for LaBraM, and 3.26% for CBraMod, with a maximum gain of 13.02% on 12-class steady-state visual evoked potential (SSVEP) classification. Visualizations of the learned atlas representations reveal task-dependent spatial patterns, with SSVEP showing a more concentrated representation in the Yeo Visual network than auditory P300. These results establish cortical alignment as a learnable and anatomically grounded routing mechanism from heterogeneous EEG montages to pretrained foundation models.

0.39

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.67
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11