CS Paper Radar

Daily listing

2026-10-29 · q-bio.QM

5 papers first submitted this day (UTC) in q-bio.QM — q-bio.QM. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 2

Agentic LLM reasoning in pediatric diabetes outcome prediction from multimodal medical records

cs.CL q-bio.QM ·2026-10-29 ·Daniel Palacios, Guantong Qi, Anna Kadi, Natali Borrego, Sukru Aras +6 more
Abstract · 18 pages main text plus 40 pages Supplementary Information

Large language model (LLM) agents are proposed for clinical prediction but are untested in pediatrics, where cohorts are small and outcomes are uncommon. Using records from 2,489 youth with type 2 diabetes (T2D) and 4,018 with type 1 diabetes (T1D), spanning structured data, note-derived social determinants and, in T1D, continuous glucose monitoring data, we predicted seven T2D outcomes, four also in T1D, at 24 months from 18 months of follow-up. CEDAR (Clinical Evidence-Driven Agent for Risk-prediction), an evidence-citing, self-auditing LLM pipeline, outperformed trained machine learning in both cohorts (pooled area under the receiver operating characteristic curve 0.815 versus 0.656 to 0.700 in T2D and 0.756 versus 0.603 to 0.631 in T1D), most on the sparsely screened outcomes. Only 4 of 70,246 values it cited did not match the chart. Reading only the evidence and reasoning cited by CEDAR, two pediatric endocrinologists reached the same prediction as CEDAR in about nine of ten cases, agreeing with each other on 90.5%.

0.31

Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift

cs.CV q-bio.QMstat.ME ·2026-10-29 ·David Regev, Eran Beeri Bamani
Abstract · 6 pages + 2-page appendix, 4 figures, 2 supplementary figures, 2 tables. Submitted to the 2027 IEEE International Conference on Rehabilitati…

Video-based gait assessment often keeps only high-confidence pose observations, which can lower measurement error but change the movement assessed. We compared confidence selection with budget-matched random selection in a Parkinson-related cohort (n = 96) and an NF2-related replication cohort (n = 18). In the Parkinson-related cohort, confidence selection produced a small but consistent shift in the observed movement summary (+0.05 SD, 95% CI 0.03 to 0.07), while held-out Mini-BESTest error stayed flat (-0.04 points, -0.13 to 0.05); a policy preserving motion-group proportions reduced the shift, while NF2 showed no shift and its predictor did not beat a constant baseline. Because this shift mixes measurement error with selection shift, we decompose and simulate both on the cohort's window structure. Filtering lowers local error when error depends on confidence, but biases the endpoint once confidence tracks movement more than error. In the Parkinson-related data, confidence was only weakly tied to movement (rho = 0.14). There, filtering is harmless if well-tracked windows are unbiased. If instead systematic error only redistributes within participants, filtering can add up to 0.58 degrees. Unchanged clinical error from such small-cohort predictors therefore cannot show that quality filtering preserves the assessed movement.

0.30