CS Paper Radar

Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift

David Regev, Eran Beeri Bamani

cs.CV q-bio.QMstat.ME ·submitted 2026-10-29 09:37 UTC · v1

Abstract

Video-based gait assessment often keeps only high-confidence pose observations, which can lower measurement error but change the movement assessed. We compared confidence selection with budget-matched random selection in a Parkinson-related cohort (n = 96) and an NF2-related replication cohort (n = 18). In the Parkinson-related cohort, confidence selection produced a small but consistent shift in the observed movement summary (+0.05 SD, 95% CI 0.03 to 0.07), while held-out Mini-BESTest error stayed flat (-0.04 points, -0.13 to 0.05); a policy preserving motion-group proportions reduced the shift, while NF2 showed no shift and its predictor did not beat a constant baseline. Because this shift mixes measurement error with selection shift, we decompose and simulate both on the cohort's window structure. Filtering lowers local error when error depends on confidence, but biases the endpoint once confidence tracks movement more than error. In the Parkinson-related data, confidence was only weakly tied to movement (rho = 0.14). There, filtering is harmless if well-tracked windows are unbiased. If instead systematic error only redistributes within participants, filtering can add up to 0.58 degrees. Unchanged clinical error from such small-cohort predictors therefore cannot show that quality filtering preserves the assessed movement.

Comment
6 pages + 2-page appendix, 4 figures, 2 supplementary figures, 2 tables. Submitted to the 2027 IEEE International Conference on Rehabilitation Robotics (ICORR)

Closest papers

Nearest neighbours by meaning across the whole index.

More Motion Is Not Always Better Motion: Corpus Composition Governs Whether Augmentation Helps SMPL-Based Parkinsonian Gait Severity Estimation

cs.CV ·2026-08-24 ·Michael Caiola, Andrew C. Weitz
similarity 0.66
Abstract · 16 pages, 4 figures, 5 tables. v2: corrects the external-source measurements in Sec. 3.4 and Fig. 3; conclusions unchanged

We grade MDS-UPDRS gait severity from SMPL motion using three frozen MotionAGFormer encoders as featurizers, reaching macro-F1 0.58 on a hidden, multi-site test set. Because the system's members differ only in their lifting corpus, evaluating encoders singly on that test set isolates what that corpus contributes. Six pools drawn from one inertial dataset, varying only in which walking tasks they include, score between 0.32 and 0.53, and just one of them beats the 0.51 of an encoder given no outside motion at all. What separates them is not how much data they hold but whether they carry a contrast in walking speed, the variation this representation appears to depend : a further pool adding a third collection site at fixed task composition does worse still. The same rule explains why exact synthetic motion and monocularly reconstructed web video both fail to help. Modifying the learned representation itself, rather than the corpus behind it, cost every variant that attempted it.

0.30

Aggregate, Don't Adapt: Subject-Level Posterior Aggregation and Transductive Calibration for Cross-Site Parkinsonian Gait Severity

cs.CV cs.AI ·2026-08-20 ·Junlong Shen
benchmark similarity 0.63
Abstract

We describe the winning entry to the MoCha 2026 Benchmark and Challenge on Parkinsonian Gait, which predicts MDS-UPDRS gait severity from canonicalized SMPL motion recorded at clinical sites unseen during training. The system reaches 0.6945 macro-F1 on the hidden test and ranked first of 58 entries, ahead of the runner-up at 0.5807 and the organizers' baseline at 0.4289, on a frozen public motion encoder with a single $4\times512$ linear layer. Nearly all of the margin comes from three stages usually treated as bookkeeping: reproducing the reference benchmark's exact head recipe, averaging per-walk posteriors within the subject grouping the organizers ship, and a label-free transductive calibration of the feature mean and the decision operating point. Fine-tuning the encoder lost in four distinct forms, and ten alternative encoders were worse. Every ablation number is a paid read on the hidden test, because our own leave-two-cohort-out cross-validation proved anti-correlated with the deciding score over eleven configurations. We give the negative record in full, and identify our largest gain, subject-level aggregation, as the binding ceiling on this benchmark.

0.35

Cross-Sectional Separability versus Longitudinal Response in Short-Record Parkinsonian Gait Analysis Using FEG-Pro: Nordic Walking and Adapted Physical Activity

eess.SP ·2026-08-16 ·Xuanbao Xiang, Andrei Velichko, Xiaobo Rao, Jianshe Gao
similarity 0.63
Abstract · 27 pages, 7 figures

\textbf{Objective:} Machine-learning separation of rehabilitation cohorts does not inherently establish a differential intervention response. This study used Forecast-Error Growth Profiling (FEG-Pro) to distinguish cross-sectional cohort separability from subject-level longitudinal change following Nordic Walking (NW) and Adapted Physical Activity (APA) in Parkinson's disease. \textbf{Methods:} Publicly available short gait records from 24 participants (NW=14, APA=10) were analyzed. Lower-limb signals at baseline and 12 weeks were transformed into FEG-Pro and Forecast-Error Distribution Entropy descriptors. We compared individual change scores ($Δ=T1-T0$) between groups using baseline-adjusted sensitivity analyses and false-discovery-rate (FDR) correction. Additionally, a fully nested machine-learning pipeline evaluated whether multidimensional change vectors could identify the intervention. \textbf{Results:} The self-selected cohorts already differed clinically at baseline. Among 1,098 extracted features, none exhibited robust between-group differences in longitudinal change after FDR correction or baseline adjustment. Furthermore, nested classification based on multidimensional change vectors failed to perform above chance (mean MCC = $-0.178 \pm 0.228$). In contrast, exploratory cross-sectional models separated the cohorts with peak MCC values of 0.604 at baseline and 0.554 post-intervention. \textbf{Conclusion:} This cohort did not provide robust evidence of modality-specific longitudinal responses to NW or APA. These findings demonstrate that cross-sectional separability of self-selected cohorts must not be interpreted as an intervention effect; true rehabilitation biomarkers require subject-level longitudinal validation, baseline adjustment, and leakage-safe evaluation.

0.10

When Participant Disjoint Validation Is Not Enough to Establish Generalization in Parkinson's Gait Classification

cs.LG ·2026-10-12 ·Md. Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid
similarity 0.61
Abstract · 9 pages, 5 figures. Includes supplementary analyses integrated into the appendices

Participant-disjoint cross-validation prevents direct participant overlap, but it may still produce optimistic estimates when acquisition site and diagnosis are structurally dependent. We examined Parkinson's disease classification using 159 pressure-walkway summary features from 133 WearGait-PD participants, including 65 participants with Parkinson's disease and 68 controls. The cohort was non-factorial: two sites contained only one diagnostic group, whereas VA-Seattle was the only site containing both groups. In repeated participant-level nested cross-validation, site alone achieved an area under the receiver operating characteristic curve (AUC) of 0.955 plus or minus 0.003, exceeding the gait-feature model (0.882 plus or minus 0.014). Under the evaluated logistic-regression pipelines, adding gait features to site, age, and sex produced no measurable improvement in pooled discrimination. More site-controlled evaluations produced lower and imprecise estimates: VA-Seattle same-site AUC was 0.668 (95% bootstrap confidence interval 0.477 to 0.836), and the JHOC + Bayview-to-VA-Seattle transport stress test achieved 0.576 (0.375 to 0.770). Supporting within-diagnosis site-prediction and site-conditioned permutation analyses showed that the gait representation retained substantial acquisition-site structure. These findings indicate that participant-disjoint pooled validation did not isolate disease-related discrimination from site-associated variation. They encourage careful examination of site-label dependence and, where possible, support for pooled results through within-site or independent validation before broader claims are made about generalization across institutions.

0.13

Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism

cs.CV ·2026-09-08 ·Aryan Singh, Chandan Biswas
similarity 0.61
Abstract · 10 pages, 4 figures

Objective assessment of Freezing of Gait (FoG) in Parkinson's disease (PD) relies predominantly on wearable Inertial Measurement Units (IMUs). While IMUs provide optimal kinematic precision, mandatory sensor attachment restricts continuous clinical deployment. Conversely, unobtrusive vision-based alternatives suffer substantial classification errors during turning-in-place tasks, where geometric self-occlusion degrades deterministic skeletal coordinates and obscures the high-frequency precursors required for FoG detection. To resolve these physical observation limits, we propose a supervised cross-modal subspace distillation framework. During optimisation, pre-trained kinematic data from IMU sensors and contextual clinical metadata act as oracles to guide a deployable visual architecture. By incorporating joint velocity and acceleration derivatives, utilising a confidence-based gating mechanism, the visual model mitigates some of the tracking errors during occlusion events. Empirical evaluations confirm this latent alignment transfers the predictive fidelity of hardware sensors directly into the visual representation, yielding $85.5\%$ accuracy, and $82.4\%$ balanced accuracy. All the while maintaining a vision only model at inference.

0.25

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

cs.CV ·2026-09-08 ·Soroush Mehraban, Xin Lei Lin, Vida Adeli, Majid Mirmehdi, Amirhossein Dadashzadeh +3 more
benchmarkcode/data similarity 0.59
Abstract · Project Page: https://soroushmehraban.github.io/SynthGait-19k/

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset containing 19,272 walking videos derived from 6,427 MoCap sequences across 437 subjects, with paired SMPL motion and annotations for six gait parameters. To construct the dataset, we develop Gait2Vid, which unifies heterogeneous MoCap recordings through SMPL and synthesizes diverse RGB walking videos under controllable viewpoints and scene appearances. We assess the generated videos for consistency with their conditioning gait kinematics and validate extracted gait events against force-platform measurements. Using SynthGait-19K, we benchmark direct RGB, pose-based, biomechanical, and human-mesh-recovery approaches and analyze viewpoint, training-data scale, and synthetic-to-real domain shift. We also introduce GaitXFormer as a direct RGB reference model for estimating gait parameters. Synthetic supervision transfers effectively to real videos across both GaitXFormer and a pose-based architecture, demonstrating utility across different representations. We further find that spatial gait parameters are more sensitive to visual domain shift and that improved HMR reconstruction alone does not necessarily translate to improved downstream gait estimation.

0.34

Towards Context-Aware Clinical Motion Understanding in Daily Living at Home: Freezing of Gait Detection with Egocentric Vision

cs.AI ·2026-08-13 ·Vayalet Stefanova, Diwas Lamsal, Margot Genbrugge, Maxim Yudayev, Christian Schlenstedt +3 more
published similarity 0.58
Abstract · Accepted to ECCV Workshop 2026 (Human Motion Challenges in Real-World and Clinical Settings)

Understanding motion in daily living requires context beyond kinematics, because similar inertial patterns during activities of daily living (ADLs) can reflect intentional stopping, object interaction, or pathological movement impairment. Egocentric vision provides task-related context that may help disambiguate these cases. We investigate this challenge through freezing of gait (FOG) detection in Parkinson's disease (PD), a symptom strongly influenced by contextual factors during ADLs. Using synchronized egocentric video, wearable IMUs, and expert-annotated FOG labels collected from 13 PD participants in their homes, we evaluate frozen representations from pretrained ego-video and time-series foundation models, alongside an IMU-based TCN trained from scratch, under leave-one-subject-out evaluation. The IMU-based TCN achieved the strongest event-detection performance, reaching 42.3 F1 and 83.0 AUROC, compared with 32.6 F1 and 77.2 AUROC for V-JEPA2 ego-video features. Although ego-video alone did not outperform IMU-based sensing, it showed above-chance discrimination, and qualitative analyses suggest that egocentric vision may capture FOG-relevant information independent of IMUs. Together, these results support the use of pretrained ego-video representations to add contextual information to wearable-sensor-based clinical motion understanding in daily living.

0.20

Temporal and spatial couplings in the dynamics of human walking and running

eess.SY q-bio.QM ·2026-10-29 ·Mustafa Mert Ankarali
similarity 0.58
Abstract

Rhythmic behaviours such as walking and running are commonly modelled as dynamical systems around a stable limit cycle. To keep such models tractable, it is usually assumed that each step depends only on the previous one, that the limit cycle is fixed, and that the sagittal and frontal planes can be studied separately. Here, we test these assumptions in seven public datasets of human gait (71 participants), including 16 people who both walked and ran. We fit linear step-to-step maps and validate them by cross-validation, holding out more data where more data exist. At first sight, gait has memory: the state two steps back lowers the prediction error by up to 29\%. Yet most of this temporal coupling vanishes once the operating point may drift slowly and measurement noise is modelled; gait remains limit-cycle-like, around an operating point that moves. Running keeps more memory than walking in the same people. Spatial coupling between the planes is present in most participants, mainly from sagittal to frontal, but weak. This supports planar models of healthy gait, while a repeatable, task-dependent coupling index may serve as a measure of gait quality. The simple models are wrong, but useful enough.

0.32