CS Paper Radar

Aggregate, Don't Adapt: Subject-Level Posterior Aggregation and Transductive Calibration for Cross-Site Parkinsonian Gait Severity

Junlong Shen

cs.CV cs.AI ·submitted 2026-08-20 21:49 UTC · v1
benchmark

Abstract

We describe the winning entry to the MoCha 2026 Benchmark and Challenge on Parkinsonian Gait, which predicts MDS-UPDRS gait severity from canonicalized SMPL motion recorded at clinical sites unseen during training. The system reaches 0.6945 macro-F1 on the hidden test and ranked first of 58 entries, ahead of the runner-up at 0.5807 and the organizers' baseline at 0.4289, on a frozen public motion encoder with a single $4\times512$ linear layer. Nearly all of the margin comes from three stages usually treated as bookkeeping: reproducing the reference benchmark's exact head recipe, averaging per-walk posteriors within the subject grouping the organizers ship, and a label-free transductive calibration of the feature mean and the decision operating point. Fine-tuning the encoder lost in four distinct forms, and ten alternative encoders were worse. Every ablation number is a paid read on the hidden test, because our own leave-two-cohort-out cross-validation proved anti-correlated with the deciding score over eleven configurations. We give the negative record in full, and identify our largest gain, subject-level aggregation, as the binding ceiling on this benchmark.

Closest papers

Nearest neighbours by meaning across the whole index.

More Motion Is Not Always Better Motion: Corpus Composition Governs Whether Augmentation Helps SMPL-Based Parkinsonian Gait Severity Estimation

cs.CV ·2026-08-24 ·Michael Caiola, Andrew C. Weitz
similarity 0.77
Abstract · 16 pages, 4 figures, 5 tables. v2: corrects the external-source measurements in Sec. 3.4 and Fig. 3; conclusions unchanged

We grade MDS-UPDRS gait severity from SMPL motion using three frozen MotionAGFormer encoders as featurizers, reaching macro-F1 0.58 on a hidden, multi-site test set. Because the system's members differ only in their lifting corpus, evaluating encoders singly on that test set isolates what that corpus contributes. Six pools drawn from one inertial dataset, varying only in which walking tasks they include, score between 0.32 and 0.53, and just one of them beats the 0.51 of an encoder given no outside motion at all. What separates them is not how much data they hold but whether they carry a contrast in walking speed, the variation this representation appears to depend : a further pool adding a third collection site at fixed task composition does worse still. The same rule explains why exact synthetic motion and monocularly reconstructed web video both fail to help. Modifying the learned representation itself, rather than the corpus behind it, cost every variant that attempted it.

0.30

When Participant Disjoint Validation Is Not Enough to Establish Generalization in Parkinson's Gait Classification

cs.LG ·2026-10-12 ·Md. Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid
similarity 0.69
Abstract · 9 pages, 5 figures. Includes supplementary analyses integrated into the appendices

Participant-disjoint cross-validation prevents direct participant overlap, but it may still produce optimistic estimates when acquisition site and diagnosis are structurally dependent. We examined Parkinson's disease classification using 159 pressure-walkway summary features from 133 WearGait-PD participants, including 65 participants with Parkinson's disease and 68 controls. The cohort was non-factorial: two sites contained only one diagnostic group, whereas VA-Seattle was the only site containing both groups. In repeated participant-level nested cross-validation, site alone achieved an area under the receiver operating characteristic curve (AUC) of 0.955 plus or minus 0.003, exceeding the gait-feature model (0.882 plus or minus 0.014). Under the evaluated logistic-regression pipelines, adding gait features to site, age, and sex produced no measurable improvement in pooled discrimination. More site-controlled evaluations produced lower and imprecise estimates: VA-Seattle same-site AUC was 0.668 (95% bootstrap confidence interval 0.477 to 0.836), and the JHOC + Bayview-to-VA-Seattle transport stress test achieved 0.576 (0.375 to 0.770). Supporting within-diagnosis site-prediction and site-conditioned permutation analyses showed that the gait representation retained substantial acquisition-site structure. These findings indicate that participant-disjoint pooled validation did not isolate disease-related discrimination from site-associated variation. They encourage careful examination of site-label dependence and, where possible, support for pooled results through within-site or independent validation before broader claims are made about generalization across institutions.

0.13

Cross-Sectional Separability versus Longitudinal Response in Short-Record Parkinsonian Gait Analysis Using FEG-Pro: Nordic Walking and Adapted Physical Activity

eess.SP ·2026-08-16 ·Xuanbao Xiang, Andrei Velichko, Xiaobo Rao, Jianshe Gao
similarity 0.66
Abstract · 27 pages, 7 figures

\textbf{Objective:} Machine-learning separation of rehabilitation cohorts does not inherently establish a differential intervention response. This study used Forecast-Error Growth Profiling (FEG-Pro) to distinguish cross-sectional cohort separability from subject-level longitudinal change following Nordic Walking (NW) and Adapted Physical Activity (APA) in Parkinson's disease. \textbf{Methods:} Publicly available short gait records from 24 participants (NW=14, APA=10) were analyzed. Lower-limb signals at baseline and 12 weeks were transformed into FEG-Pro and Forecast-Error Distribution Entropy descriptors. We compared individual change scores ($Δ=T1-T0$) between groups using baseline-adjusted sensitivity analyses and false-discovery-rate (FDR) correction. Additionally, a fully nested machine-learning pipeline evaluated whether multidimensional change vectors could identify the intervention. \textbf{Results:} The self-selected cohorts already differed clinically at baseline. Among 1,098 extracted features, none exhibited robust between-group differences in longitudinal change after FDR correction or baseline adjustment. Furthermore, nested classification based on multidimensional change vectors failed to perform above chance (mean MCC = $-0.178 \pm 0.228$). In contrast, exploratory cross-sectional models separated the cohorts with peak MCC values of 0.604 at baseline and 0.554 post-intervention. \textbf{Conclusion:} This cohort did not provide robust evidence of modality-specific longitudinal responses to NW or APA. These findings demonstrate that cross-sectional separability of self-selected cohorts must not be interpreted as an intervention effect; true rehabilitation biomarkers require subject-level longitudinal validation, baseline adjustment, and leakage-safe evaluation.

0.10

A Compact Stance-Indexed Anterior-Posterior COP Representation for Parkinson's Disease Classification from Plantar VGRF

cs.AI ·2026-09-19 ·Md. Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid
similarity 0.64
Abstract · 24 pages, 7 figures; supplementary material is included in the same PDF

Parkinson's disease alters gait and bilateral coordination, but machine-learning performance also depends on how continuous gait signals are represented. This study investigates whether preserving anterior-posterior center-of-pressure (AP-COP) information at fixed locations across normalized stance provides a compact and informative representation of plantar-force gait signals. Bilateral vertical ground reaction force recordings from 165 participants in the Gait in Parkinson's Disease Database were evaluated using repeated fully nested participant-level cross-validation. We propose AP-COP10, comprising AP-COP position and bilateral asymmetry across five stance windows. AP-COP10 achieved an AUC of 0.894 and outperformed three harmonized literature-derived COP representations under the same evaluation pipeline. The complementary 25 non-AP-COP descriptors alone achieved an AUC of 0.856, while the complete 35-feature representation achieved 0.908. Removing AP-COP10 from the complete representation produced a statistically supported loss in discrimination, whereas adding the complementary descriptors to AP-COP10 yielded only a small, unsupported improvement. Feature competition indicated that the most informative stance-indexed descriptors were concentrated in early and early-mid stance, while source-study holdout and sensor-perturbation analyses supported the robustness of the representation. These findings indicate that stance-indexed AP-COP retains discriminative information that is not readily recovered by broader engineered gait descriptors, supporting compact and interpretable representations for machine-learning analysis of pathological gait.

0.27

Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift

cs.CV q-bio.QMstat.ME ·2026-10-29 ·David Regev, Eran Beeri Bamani
similarity 0.63
Abstract · 6 pages + 2-page appendix, 4 figures, 2 supplementary figures, 2 tables. Submitted to the 2027 IEEE International Conference on Rehabilitati…

Video-based gait assessment often keeps only high-confidence pose observations, which can lower measurement error but change the movement assessed. We compared confidence selection with budget-matched random selection in a Parkinson-related cohort (n = 96) and an NF2-related replication cohort (n = 18). In the Parkinson-related cohort, confidence selection produced a small but consistent shift in the observed movement summary (+0.05 SD, 95% CI 0.03 to 0.07), while held-out Mini-BESTest error stayed flat (-0.04 points, -0.13 to 0.05); a policy preserving motion-group proportions reduced the shift, while NF2 showed no shift and its predictor did not beat a constant baseline. Because this shift mixes measurement error with selection shift, we decompose and simulate both on the cohort's window structure. Filtering lowers local error when error depends on confidence, but biases the endpoint once confidence tracks movement more than error. In the Parkinson-related data, confidence was only weakly tied to movement (rho = 0.14). There, filtering is harmless if well-tracked windows are unbiased. If instead systematic error only redistributes within participants, filtering can add up to 0.58 degrees. Unchanged clinical error from such small-cohort predictors therefore cannot show that quality filtering preserves the assessed movement.

0.30

Beyond Endpoint Gains: A Weight-Delta Audit of Medical Specialization

cs.AI ·2026-08-21 ·Praphul Singh, Shanu Kumar, Akshat Agarwal
top venuebenchmarkhot direction similarity 0.60
Abstract · Preprint: EMNLP 2026

Specialist language models are usually understood through endpoint gains: the generalist scores lower, the specialist scores higher, and the difference is treated as evidence of specialization. This leaves the released update itself largely unexamined. We propose a paired weight-delta path audit and apply it to two public, aligned generalist-to-medical-specialist checkpoint pairs: Gemma-3-4B-IT to MedGemma-4B-IT and Qwen2.5-7B-Instruct to HuatuoGPT-o1-7B. In both pairs, the full decoder-side update strongly reconstructs measured medical benchmark movement (0.974 and 1.183 endpoint-normalized retention), making each decoder delta an appropriate substrate for the audit. Yet the movement is not cleanly localized. MLP is the strongest broad component family in both pairs, but mixed off-domain movements, 10-seed matched controls, and endpoint-anchored rollbacks prevent a unique coarse-family explanation. The audit therefore separates update-level reconstruction from component-level explanation. Its claims concern text-only multiple-choice benchmark movement, not clinical validation, repair, or circuit-level mechanism.

0.50

Repeated-Measure Leakage, Distribution Shift, and Reliability under Partial Observation in Patient World Models

cs.LG ·2026-10-03 ·Arjun Subramanian
publishedcode/data similarity 0.60
Abstract · 13 pages, 7 figures. Selected for oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS) Replication P…

Patient world models are increasingly proposed for longitudinal prediction, intervention-aware reasoning, and clinical-trial simulation. Causal or clinical intervention validity is distinct from predictive generalization and reliability; before making stronger claims, the underlying predictive state should generalize across patients, survive realistic shifts and missing observations, and expose failure through meaningful reliability signals. We evaluate these prerequisites in a deliberately narrow setting: short-horizon digital-biomarker forecasting from PhysioNet GaitPDB, comprising 165 participants, 306 recordings, and 51,129 context-future pairs. Using persistence, ridge, MLP, GRU, Transformer, and a compact JEPA-style predictor, we build an evaluation ladder that progressively removes raw temporal overlap, same-recording familiarity, and same-patient familiarity before testing unseen-patient generalization. For GRU, NMSE rises from 0.1227 under random-window splitting to 0.1393 after eliminating raw train-test overlap and to 0.1961 under patient holdout. Among 54 participants with repeated recordings, exposure to a different recording from the same patient improves GRU NMSE from 0.2177 to 0.1556, while a recording-excluded identity hypothesis is not supported at the participant level. Under participant-held-out evaluation, MLP and Transformer are statistically indistinguishable. Study shift, a four-times-longer prediction gap, and partial observation further degrade performance; under 50% temporal masking, Transformer NMSE rises to 0.611 while MC-dropout predictive variance falls. We do not claim a longitudinal or intervention-aware simulator. Instead, the results support a prerequisite evaluation stack of patient separation, repeated-measure controls, shift, missingness, and uncertainty validation before stronger patient-world-model claims are trusted.

0.39

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

cs.RO ·2026-09-14 ·Hyungseok Ryu, Pilwon Hur
similarity 0.60
Abstract · 11 pages

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

0.20