CS Paper Radar

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

Hyungseok Ryu, Pilwon Hur

cs.RO ·submitted 2026-09-14 03:42 UTC · v1
top venue

Abstract

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

Comment
11 pages

Closest papers

Nearest neighbours by meaning across the whole index.

PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking

cs.RO ·2026-09-30 ·Kaijie Qi, Yuehan Wang, Kaiming Xu, Chong Li, Jiakuo Yu
similarity 0.69
Abstract

Human-aware exoskeleton walking requires reconstructing gait, tracking diverse motions under dynamic constraints, and preserving human timing. We present PhaseSync-Exo, which combines two-IMU CNN-Transformer reconstruction, factorized amplitude-cadence retargeting with curriculum-trained recurrent control, and a human-clock-anchored adapter (HCA). HCA combines human-clock attraction with robot-relative feedback to adjust reference rate while preserving forward progression and continuity. The reconstruction module achieves a mean absolute error (MAE) of 3.24 degrees on a held-out recording, and the frozen tracking policy completes 356 of 357 amplitude-frequency trials. Two complementary dynamic comparisons isolate HCA's timing benefit without retraining. Against robot-relative correction, HCA reduces human-clock phase MAE from 95.55 degrees to 10.99 degrees, limiting reference drift. When human and delivered phases initially differ, it reduces phase MAE from 72.02 degrees to 13.90 degrees versus fixed-clock continuation. Compared with immediate phase reset, HCA reduces transient reference-tracking hip RMSE by 22.7% without reference jumps. All 420 timing rollouts complete without falls. These simulation results support continuous phase acquisition and sustained alignment to an independent human clock.

0.23

Adaptive Gait Biofeedback With Participant-Held-Out Modeling and Participant-Specific Updating in Chronic Ankle Instability

cs.AI eess.SP ·2026-10-05 ·Jaeyoon Kim, Veronika Lebisova, Jeniya Sultana, Jaeyoung Cho, Jaeho Jang
similarity 0.66
Abstract · 28 pages (14-page main manuscript and 14-page supplementary material), 5 main figures

Adaptive gait biofeedback may support repeated practice in chronic ankle instability, but its evaluation must address model performance and human response. We evaluated a temporal convolutional classifier on protocol-defined, angle-derived GOOD/BAD gait-cycle labels using participant-held-out leave-one-subject-out (LOSO) cross-validation in 20 participants. Seven participants in the adaptive-intervention group completed nine sessions over three weeks, with one motion-capture recording analyzed per session. Models updated after failed sessions were compared offline with their parent models on the same-session validation subset used for candidate selection and the first subsequent adaptive-session recording. Frontal-plane ankle angle was compared between the adaptive group and 10 sequentially enrolled controls at Baseline, Post, and 7-day Retention. Across 20 held-out folds, mean fold-level area under the receiver operating characteristic curve (AUROC) was 0.948, sensitivity for angle-threshold-exceeding BAD cycles was 0.941, and specificity for angle-threshold-meeting GOOD cycles was 0.366. Mean BAD-class F1 was higher in candidate models by 0.187 on the same-session subset and 0.118 on the first subsequent recording. At Post, the adaptive group had a baseline-adjusted frontal-plane ankle angle 5.168 degrees lower than controls (95% confidence interval, 1.766-8.569 degrees lower); the Retention contrast was uncertain. These findings characterize population-model discrimination and offline participant-specific updating during repeated biofeedback use, alongside a nonrandomized Post frontal-plane ankle angle association. They do not establish independent clinical gait classification or a causal benefit of updating.

0.23

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.65
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.20

Sparse Calibration-Based Personalization of Kernel-Based Gait Phase and Speed Estimation Using Wearable IMUs

cs.RO ·2026-10-02 ·Myeongju Cha, Pilwon Hur
similarity 0.65
Abstract · 6 pages, 4 figures, The 26th International Conference on Control, Automation, and Systems (ICCAS 2026)

This paper presents sparse calibration-based personalization for kernel-based gait phase and walking speed co-estimation from wearable inertial measurement units (IMUs). A 28-speed reference library was constructed from bilateral thigh and shank trajectories in a 20-subject locomotion dataset. Rather than directly applying population-average kernels, the method combines a user-specific baseline estimated from three calibration speeds with a principal-component (PC) model of baseline-centered kinematic deviations. Offline validation showed that personalized kernels reduced phase error relative to the population kernel. In a single-participant online pilot evaluation, the personalized kernels produced numerically lower mean phase and speed errors and ran in real time on embedded hardware. However, the speed effect was not significant, and pairwise phase differences did not remain significant after multiple-comparison correction. The pilot evaluation establishes wearable implementation feasibility while indicating reference-to-online dataset mismatch and the need for larger-cohort validation.

0.19

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.64
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13

Cross-Sectional Separability versus Longitudinal Response in Short-Record Parkinsonian Gait Analysis Using FEG-Pro: Nordic Walking and Adapted Physical Activity

eess.SP ·2026-08-16 ·Xuanbao Xiang, Andrei Velichko, Xiaobo Rao, Jianshe Gao
similarity 0.63
Abstract · 27 pages, 7 figures

\textbf{Objective:} Machine-learning separation of rehabilitation cohorts does not inherently establish a differential intervention response. This study used Forecast-Error Growth Profiling (FEG-Pro) to distinguish cross-sectional cohort separability from subject-level longitudinal change following Nordic Walking (NW) and Adapted Physical Activity (APA) in Parkinson's disease. \textbf{Methods:} Publicly available short gait records from 24 participants (NW=14, APA=10) were analyzed. Lower-limb signals at baseline and 12 weeks were transformed into FEG-Pro and Forecast-Error Distribution Entropy descriptors. We compared individual change scores ($Δ=T1-T0$) between groups using baseline-adjusted sensitivity analyses and false-discovery-rate (FDR) correction. Additionally, a fully nested machine-learning pipeline evaluated whether multidimensional change vectors could identify the intervention. \textbf{Results:} The self-selected cohorts already differed clinically at baseline. Among 1,098 extracted features, none exhibited robust between-group differences in longitudinal change after FDR correction or baseline adjustment. Furthermore, nested classification based on multidimensional change vectors failed to perform above chance (mean MCC = $-0.178 \pm 0.228$). In contrast, exploratory cross-sectional models separated the cohorts with peak MCC values of 0.604 at baseline and 0.554 post-intervention. \textbf{Conclusion:} This cohort did not provide robust evidence of modality-specific longitudinal responses to NW or APA. These findings demonstrate that cross-sectional separability of self-selected cohorts must not be interpreted as an intervention effect; true rehabilitation biomarkers require subject-level longitudinal validation, baseline adjustment, and leakage-safe evaluation.

0.10

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
similarity 0.63
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30

Diffusion-Based Generation of Gait Trajectories

cs.AI cs.LGcs.RO ·2026-09-13 ·Damian Benasco, Juan Carballeira-Lopez, Jaime Ramos-Rojas, Julio S. Lora-Millan, Antonio J. Del-Ama +2 more
hot direction similarity 0.62
Abstract · International Conference on NeuroRehabilitation (ICNR2026), September 29-October 2, 2026, Seoul, South Korea

Generation of musculoskeletal gait trajectories conditioned on patient-specific parameters remains a key challenge for wearable robotics and rehabilitation. Assistive systems such as lower-limb exoskeletons require reference trajectories that adapt to individual morphology and therapeutic goals while preserving biomechanical realism. Traditional approaches rely on hand-crafted gait templates or optimization procedures that scale poorly across subjects and walking conditions. In this work, we explore conditional diffusion models for generating lower-limb joint-angle trajectories conditioned on gait parameters such as step length. We compare a baseline transformer diffusion model with a controllable diffusion transformer variant incorporating adaptive normalization and classifier-free guidance. Experiments on a dataset of 4,590 gait cycles show that diffusion models can generate realistic periodic gait trajectories while enabling some controllability variation in gait characteristics, highlighting their potential for personalized gait synthesis in assistive robotics.

0.39