CS Paper Radar

Adaptive Gait Biofeedback With Participant-Held-Out Modeling and Participant-Specific Updating in Chronic Ankle Instability

Jaeyoon Kim, Veronika Lebisova, Jeniya Sultana, Jaeyoung Cho, Jaeho Jang

cs.AI eess.SP ·submitted 2026-10-05 21:36 UTC · v2

Abstract

Adaptive gait biofeedback may support repeated practice in chronic ankle instability, but its evaluation must address model performance and human response. We evaluated a temporal convolutional classifier on protocol-defined, angle-derived GOOD/BAD gait-cycle labels using participant-held-out leave-one-subject-out (LOSO) cross-validation in 20 participants. Seven participants in the adaptive-intervention group completed nine sessions over three weeks, with one motion-capture recording analyzed per session. Models updated after failed sessions were compared offline with their parent models on the same-session validation subset used for candidate selection and the first subsequent adaptive-session recording. Frontal-plane ankle angle was compared between the adaptive group and 10 sequentially enrolled controls at Baseline, Post, and 7-day Retention. Across 20 held-out folds, mean fold-level area under the receiver operating characteristic curve (AUROC) was 0.948, sensitivity for angle-threshold-exceeding BAD cycles was 0.941, and specificity for angle-threshold-meeting GOOD cycles was 0.366. Mean BAD-class F1 was higher in candidate models by 0.187 on the same-session subset and 0.118 on the first subsequent recording. At Post, the adaptive group had a baseline-adjusted frontal-plane ankle angle 5.168 degrees lower than controls (95% confidence interval, 1.766-8.569 degrees lower); the Retention contrast was uncertain. These findings characterize population-model discrimination and offline participant-specific updating during repeated biofeedback use, alongside a nonrandomized Post frontal-plane ankle angle association. They do not establish independent clinical gait classification or a causal benefit of updating.

Comment
28 pages (14-page main manuscript and 14-page supplementary material), 5 main figures

Closest papers

Nearest neighbours by meaning across the whole index.

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

cs.RO ·2026-09-14 ·Hyungseok Ryu, Pilwon Hur
similarity 0.66
Abstract · 11 pages

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

0.20

Cross-Sectional Separability versus Longitudinal Response in Short-Record Parkinsonian Gait Analysis Using FEG-Pro: Nordic Walking and Adapted Physical Activity

eess.SP ·2026-08-16 ·Xuanbao Xiang, Andrei Velichko, Xiaobo Rao, Jianshe Gao
similarity 0.62
Abstract · 27 pages, 7 figures

\textbf{Objective:} Machine-learning separation of rehabilitation cohorts does not inherently establish a differential intervention response. This study used Forecast-Error Growth Profiling (FEG-Pro) to distinguish cross-sectional cohort separability from subject-level longitudinal change following Nordic Walking (NW) and Adapted Physical Activity (APA) in Parkinson's disease. \textbf{Methods:} Publicly available short gait records from 24 participants (NW=14, APA=10) were analyzed. Lower-limb signals at baseline and 12 weeks were transformed into FEG-Pro and Forecast-Error Distribution Entropy descriptors. We compared individual change scores ($Δ=T1-T0$) between groups using baseline-adjusted sensitivity analyses and false-discovery-rate (FDR) correction. Additionally, a fully nested machine-learning pipeline evaluated whether multidimensional change vectors could identify the intervention. \textbf{Results:} The self-selected cohorts already differed clinically at baseline. Among 1,098 extracted features, none exhibited robust between-group differences in longitudinal change after FDR correction or baseline adjustment. Furthermore, nested classification based on multidimensional change vectors failed to perform above chance (mean MCC = $-0.178 \pm 0.228$). In contrast, exploratory cross-sectional models separated the cohorts with peak MCC values of 0.604 at baseline and 0.554 post-intervention. \textbf{Conclusion:} This cohort did not provide robust evidence of modality-specific longitudinal responses to NW or APA. These findings demonstrate that cross-sectional separability of self-selected cohorts must not be interpreted as an intervention effect; true rehabilitation biomarkers require subject-level longitudinal validation, baseline adjustment, and leakage-safe evaluation.

0.10

When Participant Disjoint Validation Is Not Enough to Establish Generalization in Parkinson's Gait Classification

cs.LG ·2026-10-12 ·Md. Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid
similarity 0.62
Abstract · 9 pages, 5 figures. Includes supplementary analyses integrated into the appendices

Participant-disjoint cross-validation prevents direct participant overlap, but it may still produce optimistic estimates when acquisition site and diagnosis are structurally dependent. We examined Parkinson's disease classification using 159 pressure-walkway summary features from 133 WearGait-PD participants, including 65 participants with Parkinson's disease and 68 controls. The cohort was non-factorial: two sites contained only one diagnostic group, whereas VA-Seattle was the only site containing both groups. In repeated participant-level nested cross-validation, site alone achieved an area under the receiver operating characteristic curve (AUC) of 0.955 plus or minus 0.003, exceeding the gait-feature model (0.882 plus or minus 0.014). Under the evaluated logistic-regression pipelines, adding gait features to site, age, and sex produced no measurable improvement in pooled discrimination. More site-controlled evaluations produced lower and imprecise estimates: VA-Seattle same-site AUC was 0.668 (95% bootstrap confidence interval 0.477 to 0.836), and the JHOC + Bayview-to-VA-Seattle transport stress test achieved 0.576 (0.375 to 0.770). Supporting within-diagnosis site-prediction and site-conditioned permutation analyses showed that the gait representation retained substantial acquisition-site structure. These findings indicate that participant-disjoint pooled validation did not isolate disease-related discrimination from site-associated variation. They encourage careful examination of site-label dependence and, where possible, support for pooled results through within-site or independent validation before broader claims are made about generalization across institutions.

0.13

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.60
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.29

Repeated-Measure Leakage, Distribution Shift, and Reliability under Partial Observation in Patient World Models

cs.LG ·2026-10-03 ·Arjun Subramanian
publishedcode/data similarity 0.59
Abstract · 13 pages, 7 figures. Selected for oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS) Replication P…

Patient world models are increasingly proposed for longitudinal prediction, intervention-aware reasoning, and clinical-trial simulation. Causal or clinical intervention validity is distinct from predictive generalization and reliability; before making stronger claims, the underlying predictive state should generalize across patients, survive realistic shifts and missing observations, and expose failure through meaningful reliability signals. We evaluate these prerequisites in a deliberately narrow setting: short-horizon digital-biomarker forecasting from PhysioNet GaitPDB, comprising 165 participants, 306 recordings, and 51,129 context-future pairs. Using persistence, ridge, MLP, GRU, Transformer, and a compact JEPA-style predictor, we build an evaluation ladder that progressively removes raw temporal overlap, same-recording familiarity, and same-patient familiarity before testing unseen-patient generalization. For GRU, NMSE rises from 0.1227 under random-window splitting to 0.1393 after eliminating raw train-test overlap and to 0.1961 under patient holdout. Among 54 participants with repeated recordings, exposure to a different recording from the same patient improves GRU NMSE from 0.2177 to 0.1556, while a recording-excluded identity hypothesis is not supported at the participant level. Under participant-held-out evaluation, MLP and Transformer are statistically indistinguishable. Study shift, a four-times-longer prediction gap, and partial observation further degrade performance; under 50% temporal masking, Transformer NMSE rises to 0.611 while MC-dropout predictive variance falls. We do not claim a longitudinal or intervention-aware simulator. Instead, the results support a prerequisite evaluation stack of patient separation, repeated-measure controls, shift, missingness, and uncertainty validation before stronger patient-world-model claims are trusted.

0.39

Silhouette-Based Gaitomics for Frailty Assessment in Older Adults

cs.CV ·2026-10-28 ·Laura McDaniel, Ryan Roemmich, Crystal Szczesny, Peter Abadir, Rama Chellappa +1 more
similarity 0.59
Abstract

Walking offers a window into physical function that may support interpretable video-based frailty assessment. We developed silhouette-based "gaitomics" to connect frailty predictions with measurable patterns of body configuration and movement. In 66 older adults assessed using the Fried Frailty Phenotype, standardized silhouettes and gait energy images yielded 90 descriptors of shape, temporal variation, motion, and texture. Minimum redundancy maximum relevance selection using the mutual information difference criterion prioritized informative features while limiting redundancy. Each classifier was evaluated using nested stratified cross-validation with five outer and three inner folds at the participant level, with feature ranking and feature-count selection confined to training partitions. Shapley additive explanations examined contributions to held-out predictions. Bilateral silhouette difference led the aggregate feature-selection rankings for three-class classification and both comparisons involving frail participants. Attribution profiles differed across tasks, with texture and consecutive-frame silhouette differences prominent in three-class classification. Among classifier-specific evaluations, CatBoost achieved the highest mean three-class micro-AUC of 0.647 \pm 0.085. Leading pairwise mean micro-AUCs were 0.833 \pm 0.249 for frail versus nonfrail, 0.765 \pm 0.168 for frail versus prefrail, and 0.554 \pm 0.129 for prefrail versus nonfrail classification. These findings connect model predictions to explicit gait characteristics while revealing task-dependent feature priorities and limited separation of prefrail and nonfrail participants. The framework provides an interpretable basis for further investigation, with larger independent studies needed to establish reliability and clinical relevance.

0.32

Smart Insole Human Activity Recognition for Continuous Monitoring in Elderly Care

cs.LG ·2026-09-16 ·Edwin Rios, Antony Garcia, Fengpei Yuan, Xinming Huang
similarity 0.58
Abstract

Falls in older adults are often preceded by changes in mobility, balance, and postural transitions. This paper presents a wireless smart insole platform and machine-learning workflow for recognizing sitting, standing, walking, and unstable walking from plantar-pressure and inertial signals. Each insole integrates 16 active pressure-sensing locations and a six-dimensional IMU stream consisting of tri-axial acceleration and angular velocity. Data were collected from 15 healthy adults at 80~Hz and segmented into overlapping windows. Window length and candidate model families were first screened with stratified 10-fold cross-validation; the primary performance estimate was then obtained with participant-independent 5-fold Stratified Group cross-validation, ensuring that all windows from a participant remained in a single fold. Under this protocol, Histogram-Based Gradient Boosting (HGB) achieved macro-F1 scores of 0.954 and 0.959 for the left and right feet, respectively, and 0.980 with bilateral sensing. A compact 1D-CNN evaluated with the same participant-independent folds did not significantly outperform HGB ($p=0.0625$). The results show that low-profile footwear sensing can infer activity state from pressure and IMU measurements for participants unseen during training, establishing a basis for activity monitoring and fall prevention in elderly care.

0.21

PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking

cs.RO ·2026-09-30 ·Kaijie Qi, Yuehan Wang, Kaiming Xu, Chong Li, Jiakuo Yu
similarity 0.58
Abstract

Human-aware exoskeleton walking requires reconstructing gait, tracking diverse motions under dynamic constraints, and preserving human timing. We present PhaseSync-Exo, which combines two-IMU CNN-Transformer reconstruction, factorized amplitude-cadence retargeting with curriculum-trained recurrent control, and a human-clock-anchored adapter (HCA). HCA combines human-clock attraction with robot-relative feedback to adjust reference rate while preserving forward progression and continuity. The reconstruction module achieves a mean absolute error (MAE) of 3.24 degrees on a held-out recording, and the frozen tracking policy completes 356 of 357 amplitude-frequency trials. Two complementary dynamic comparisons isolate HCA's timing benefit without retraining. Against robot-relative correction, HCA reduces human-clock phase MAE from 95.55 degrees to 10.99 degrees, limiting reference drift. When human and delivered phases initially differ, it reduces phase MAE from 72.02 degrees to 13.90 degrees versus fixed-clock continuation. Compared with immediate phase reset, HCA reduces transient reference-tracking hip RMSE by 22.7% without reference jumps. All 420 timing rollouts complete without falls. These simulation results support continuous phase acquisition and sustained alignment to an independent human clock.

0.23