CS Paper Radar

Silhouette-Based Gaitomics for Frailty Assessment in Older Adults

Laura McDaniel, Ryan Roemmich, Crystal Szczesny, Peter Abadir, Rama Chellappa, Basudha Pal

cs.CV ·submitted 2026-10-28 03:19 UTC · v1

Abstract

Walking offers a window into physical function that may support interpretable video-based frailty assessment. We developed silhouette-based "gaitomics" to connect frailty predictions with measurable patterns of body configuration and movement. In 66 older adults assessed using the Fried Frailty Phenotype, standardized silhouettes and gait energy images yielded 90 descriptors of shape, temporal variation, motion, and texture. Minimum redundancy maximum relevance selection using the mutual information difference criterion prioritized informative features while limiting redundancy. Each classifier was evaluated using nested stratified cross-validation with five outer and three inner folds at the participant level, with feature ranking and feature-count selection confined to training partitions. Shapley additive explanations examined contributions to held-out predictions. Bilateral silhouette difference led the aggregate feature-selection rankings for three-class classification and both comparisons involving frail participants. Attribution profiles differed across tasks, with texture and consecutive-frame silhouette differences prominent in three-class classification. Among classifier-specific evaluations, CatBoost achieved the highest mean three-class micro-AUC of 0.647 \pm 0.085. Leading pairwise mean micro-AUCs were 0.833 \pm 0.249 for frail versus nonfrail, 0.765 \pm 0.168 for frail versus prefrail, and 0.554 \pm 0.129 for prefrail versus nonfrail classification. These findings connect model predictions to explicit gait characteristics while revealing task-dependent feature priorities and limited separation of prefrail and nonfrail participants. The framework provides an interpretable basis for further investigation, with larger independent studies needed to establish reliability and clinical relevance.

Closest papers

Nearest neighbours by meaning across the whole index.

RevalExo: A Functional Daily-Activity Benchmark for Inertial and Visual Locomotion Mode Recognition in Older Adults and Clinical Cohorts

cs.AI cs.CV ·2026-09-08 ·Diwas Lamsal, Juha Carlon, Reinhard Claeys, Maxim Yudayev, Louis Flynn +6 more
publishedbenchmarkhot direction similarity 0.62
Abstract · Accepted to BMVC 2026 (Oral)

Assistive devices for people with mobility impairments, such as powered exoskeletons, rely on accurate locomotion mode recognition to adapt control strategies and provide appropriate assistance during daily activities. However, public benchmarks are typically collected from healthy adults, lack temporally precise labels necessary for detecting mode transitions, or focus on a limited set of tasks. To support development and evaluation under realistic clinical constraints and daily mobility demands, we introduce RevalExo, a functional daily-activity benchmark for inertial and visual locomotion mode recognition. RevalExo is built around a standardized, clinically and ecologically validated daily-activity protocol reflecting the cumulative everyday mobility demands in ageing and clinical populations. The benchmark includes 27 participants across three cohorts: older adults without mobility impairments, stroke survivors, and older adults with probable sarcopenia. The full cohort was recorded with lower-body IMUs, while synchronized egocentric video was collected for a clinically feasible subset of 13 participants. RevalExo provides 10.1 hours of frame-level annotations across 11 locomotion modes, including 5.1 hours of paired inertial--visual recordings. We benchmark three challenges: unimodal and multimodal locomotion mode recognition across multiple horizons, cross-population generalization from older adults without mobility impairments to clinical cohorts, and vision-guided knowledge transfer to IMU-only models. Results confirm consistent gains from fusing inertial and visual inputs but reveal a substantial gap between general recognition ($\sim$93\% F1) and recognition during transitions ($\sim$68\% F1), alongside persistent challenges in cross-population generalization and cross-modal transfer. We release RevalExo to stimulate further research on these open challenges.

0.46

Predicting Early Functional Decline from Longitudinal Laboratory and Vital Sign Trajectories: A Large-Scale Study Using the All of Us Research Program

cs.LG stat.AP ·2026-08-21 ·Rashmita Kudamala, Aravind V. Kuruvikkattil, Lalitha Pranathi Pulavarthy, Saptarshi Purkayastha
published similarity 0.60
Abstract · Accepted for presentation at American Medical Informatics Association (AMIA) Annual Symposium 2026

Functional decline in older adults is typically recognized only after falls or observable gait impairment, closing the window for prevention. We investigated whether temporal trajectories of routine biomarkers, already recorded but rarely analyzed longitudinally, can identify patients in the pre-clinical phase of mobility decline. Using the All of Us Research Program (N = 297,861; 11.1% cases), we derived trajectory features (slope, variability, delta, mean) for twelve biomarkers over a three-year pre-index window. LightGBM models incorporating trajectories significantly outperformed static laboratory summaries (AUROC 0.797 vs. 0.755; DeLong p < 0.001; AUPRC 0.380 vs. 0.304). A 1:1 age- and sex-matched analysis confirmed an independent trajectory signal (AUROC 0.727 vs. demographics-only 0.680). A horizon analysis demonstrated sustained prediction 3-12 months before decline onset (AUROC 0.768-0.740). Because the model uses only measurements already ordered in routine care, it supports passive, zero-burden EHR integration for early detection of pre-clinical functional decline.

0.29

Foundation models for movement data: Are they ready for prime-time?

eess.SP cs.LG ·2026-08-13 ·Alexander Bräuer, Benjamin Cauchi, Nils Strodthoff
code/data similarity 0.60
Abstract · 14 pages, 6 figures, 8 tables, code is available at https://github.com/AI4HealthUOL/movement-fm-benchmarking

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

0.30

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.59
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

3D Digital Twin Visualization of Multiclass GRF-Based Gait Disorder Classification

cs.LG cs.AI ·2026-09-11 ·Nayoung Son, Minwoo Shin
code/datahot direction similarity 0.59
Abstract

Automated gait analysis requires accurate classification and interpretable outputs. We propose an integrated framework for classifying healthy gait and multiple musculoskeletal impairment groups using bilateral ground reaction force (GRF) and center-of-pressure (COP) signals. The signals were normalized over the stance phase and standardized using training-set statistics. The model achieved a validation accuracy of 99.00\% and a test accuracy of 90.07\% under a session-level split. Class-specific $ε$-LRP identified positive and negative contributions across both sides, multiple signal components, and different stance phases. Separately, the processed GRF signals and model predictions were synchronized within a Blender-based 3D visualization, enabling sample-level inspection of gait trials and classification results. The proposed framework integrates classification, explainability, and 3D visualization to improve model transparency. The source code is available in the following repository: https://github.com/nyoico/grf-gait-3d-visualization.git

0.44

Smart Insole Human Activity Recognition for Continuous Monitoring in Elderly Care

cs.LG ·2026-09-16 ·Edwin Rios, Antony Garcia, Fengpei Yuan, Xinming Huang
similarity 0.59
Abstract

Falls in older adults are often preceded by changes in mobility, balance, and postural transitions. This paper presents a wireless smart insole platform and machine-learning workflow for recognizing sitting, standing, walking, and unstable walking from plantar-pressure and inertial signals. Each insole integrates 16 active pressure-sensing locations and a six-dimensional IMU stream consisting of tri-axial acceleration and angular velocity. Data were collected from 15 healthy adults at 80~Hz and segmented into overlapping windows. Window length and candidate model families were first screened with stratified 10-fold cross-validation; the primary performance estimate was then obtained with participant-independent 5-fold Stratified Group cross-validation, ensuring that all windows from a participant remained in a single fold. Under this protocol, Histogram-Based Gradient Boosting (HGB) achieved macro-F1 scores of 0.954 and 0.959 for the left and right feet, respectively, and 0.980 with bilateral sensing. A compact 1D-CNN evaluated with the same participant-independent folds did not significantly outperform HGB ($p=0.0625$). The results show that low-profile footwear sensing can infer activity state from pressure and IMU measurements for participants unseen during training, establishing a basis for activity monitoring and fall prevention in elderly care.

0.21

Adaptive Gait Biofeedback With Participant-Held-Out Modeling and Participant-Specific Updating in Chronic Ankle Instability

cs.AI eess.SP ·2026-10-05 ·Jaeyoon Kim, Veronika Lebisova, Jeniya Sultana, Jaeyoung Cho, Jaeho Jang
similarity 0.59
Abstract · 28 pages (14-page main manuscript and 14-page supplementary material), 5 main figures

Adaptive gait biofeedback may support repeated practice in chronic ankle instability, but its evaluation must address model performance and human response. We evaluated a temporal convolutional classifier on protocol-defined, angle-derived GOOD/BAD gait-cycle labels using participant-held-out leave-one-subject-out (LOSO) cross-validation in 20 participants. Seven participants in the adaptive-intervention group completed nine sessions over three weeks, with one motion-capture recording analyzed per session. Models updated after failed sessions were compared offline with their parent models on the same-session validation subset used for candidate selection and the first subsequent adaptive-session recording. Frontal-plane ankle angle was compared between the adaptive group and 10 sequentially enrolled controls at Baseline, Post, and 7-day Retention. Across 20 held-out folds, mean fold-level area under the receiver operating characteristic curve (AUROC) was 0.948, sensitivity for angle-threshold-exceeding BAD cycles was 0.941, and specificity for angle-threshold-meeting GOOD cycles was 0.366. Mean BAD-class F1 was higher in candidate models by 0.187 on the same-session subset and 0.118 on the first subsequent recording. At Post, the adaptive group had a baseline-adjusted frontal-plane ankle angle 5.168 degrees lower than controls (95% confidence interval, 1.766-8.569 degrees lower); the Retention contrast was uncertain. These findings characterize population-model discrimination and offline participant-specific updating during repeated biofeedback use, alongside a nonrandomized Post frontal-plane ankle angle association. They do not establish independent clinical gait classification or a causal benefit of updating.

0.23

MMGait: Benchmarking and Unifying Gait Recognition across Heterogeneous Modalities

cs.CV ·2026-09-10 ·Saihui Hou, Chenye Wang, Qingyuan Cai, Aoqi Li, Yongzhen Huang
benchmark similarity 0.58
Abstract · 21 pages, 6 figures

Gait recognition is commonly studied using RGB videos or their derived silhouettes and poses. Yet human walking produces heterogeneous photometric, geometric, and motion cues that cannot be systematically examined with RGB-centered benchmarks. We present MMGait, a large-scale multi-sensor benchmark that brings visible, infrared, depth, LiDAR, and radar observations into sequence-level correspondence. It provides diverse modalities spanning appearance, contours, geometry, motion, and body structure. Under a shared impostor-augmented protocol, we evaluate single-modal recognition, cross-modal recognition via directed retrieval, and multi-modal recognition using task-specific experts. Across settings, modality rankings vary with probe conditions, cross-modal alignment remains difficult, and fusion often provides complementary gains. This analysis exposes a scalability problem: individual modalities, modality pairs, and fusion configurations are typically handled by separately trained experts. We formulate Omni-Modal Gait Recognition, which unifies single-modal, cross-modal, and multi-modal recognition within a shared identity space. OmniGait++ uses modality-specific front ends followed by a shared identity encoder to preserve modality-dependent cues while learning comparable identity descriptors. An anchor-guided fusion module aggregates modality subsets of varying size without frame-level synchronization. A jointly trained checkpoint covers all three recognition settings and accommodates modality subsets of different compositions and cardinalities. Experiments show OmniGait++ remains competitive with task-specific experts in many shared settings and extends to higher-cardinality fusion unavailable to fixed-pair models. The results establish MMGait as a common testbed for heterogeneous gait sensing and demonstrate the feasibility of unified recognition under varying modality availability.

0.30