CS Paper Radar

3D Digital Twin Visualization of Multiclass GRF-Based Gait Disorder Classification

Nayoung Son, Minwoo Shin

cs.LG cs.AI ·submitted 2026-09-11 05:04 UTC · v1
code/datahot direction

Abstract

Automated gait analysis requires accurate classification and interpretable outputs. We propose an integrated framework for classifying healthy gait and multiple musculoskeletal impairment groups using bilateral ground reaction force (GRF) and center-of-pressure (COP) signals. The signals were normalized over the stance phase and standardized using training-set statistics. The model achieved a validation accuracy of 99.00\% and a test accuracy of 90.07\% under a session-level split. Class-specific $ε$-LRP identified positive and negative contributions across both sides, multiple signal components, and different stance phases. Separately, the processed GRF signals and model predictions were synchronized within a Blender-based 3D visualization, enabling sample-level inspection of gait trials and classification results. The proposed framework integrates classification, explainability, and 3D visualization to improve model transparency. The source code is available in the following repository: https://github.com/nyoico/grf-gait-3d-visualization.git

Closest papers

Nearest neighbours by meaning across the whole index.

Contactless gait-derived features as candidate digital biomarkers of depression severity in adolescents

eess.SP ·2026-10-13 ·Shuai Liu, Xiang Li, Guangxin Dai, Mengyuan Yu, Wenkong Wang +6 more
similarity 0.66
Abstract

Timely assessment of depression severity in adolescents is essential for guiding clinical care, yet conventional evaluations rely on episodic clinical assessments and symptom rating scales. Contactless gait analysis offers a potentially scalable approach to capturing objective behavioral features associated with depression. Here, we introduce the Long-Distance 3D Adolescent Depression Gait Dataset (LD3D-ADG), comprising depth-sensor gait recordings from 119 adolescents at a single center, including 39 healthy controls, 41 with mild depression, and 39 with moderate-to-severe depression. We developed UMLPA-GCN, a graph convolutional network that models spatiotemporal gait dynamics across three anatomically defined skeletal partitions. In participant-independent five-fold cross-validation, UMLPA-GCN achieved 75.63% classification accuracy, a macro-F1 score of 75.52%, and a macro-area under the receiver operating characteristic curve of 0.839 (95% confidence interval, 0.779--0.899). Class-specific recall was 87.18%, 63.41%, and 76.92% for healthy controls, mild depression, and moderate-to-severe depression, respectively. At the participant level, reduced arm swing, slower pelvic movement, restricted joint range of motion, and greater arm-swing asymmetry were identified as leading potential digital biomarkers contributing to depression severity assessment, associated with higher 17-item Hamilton Depression Rating Scale scores. These findings provide proof-of-concept evidence for contactless digital depression severity stratification in adolescents. Further external and prospective validation is needed to establish their utility for longitudinal monitoring and timely clinical assessment.

0.18

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

cs.CV ·2026-09-08 ·Soroush Mehraban, Xin Lei Lin, Vida Adeli, Majid Mirmehdi, Amirhossein Dadashzadeh +3 more
benchmarkcode/data similarity 0.65
Abstract · Project Page: https://soroushmehraban.github.io/SynthGait-19k/

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset containing 19,272 walking videos derived from 6,427 MoCap sequences across 437 subjects, with paired SMPL motion and annotations for six gait parameters. To construct the dataset, we develop Gait2Vid, which unifies heterogeneous MoCap recordings through SMPL and synthesizes diverse RGB walking videos under controllable viewpoints and scene appearances. We assess the generated videos for consistency with their conditioning gait kinematics and validate extracted gait events against force-platform measurements. Using SynthGait-19K, we benchmark direct RGB, pose-based, biomechanical, and human-mesh-recovery approaches and analyze viewpoint, training-data scale, and synthetic-to-real domain shift. We also introduce GaitXFormer as a direct RGB reference model for estimating gait parameters. Synthetic supervision transfers effectively to real videos across both GaitXFormer and a pose-based architecture, demonstrating utility across different representations. We further find that spatial gait parameters are more sensitive to visual domain shift and that improved HMR reconstruction alone does not necessarily translate to improved downstream gait estimation.

0.34

A Compact Stance-Indexed Anterior-Posterior COP Representation for Parkinson's Disease Classification from Plantar VGRF

cs.AI ·2026-09-19 ·Md. Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid
similarity 0.60
Abstract · 24 pages, 7 figures; supplementary material is included in the same PDF

Parkinson's disease alters gait and bilateral coordination, but machine-learning performance also depends on how continuous gait signals are represented. This study investigates whether preserving anterior-posterior center-of-pressure (AP-COP) information at fixed locations across normalized stance provides a compact and informative representation of plantar-force gait signals. Bilateral vertical ground reaction force recordings from 165 participants in the Gait in Parkinson's Disease Database were evaluated using repeated fully nested participant-level cross-validation. We propose AP-COP10, comprising AP-COP position and bilateral asymmetry across five stance windows. AP-COP10 achieved an AUC of 0.894 and outperformed three harmonized literature-derived COP representations under the same evaluation pipeline. The complementary 25 non-AP-COP descriptors alone achieved an AUC of 0.856, while the complete 35-feature representation achieved 0.908. Removing AP-COP10 from the complete representation produced a statistically supported loss in discrimination, whereas adding the complementary descriptors to AP-COP10 yielded only a small, unsupported improvement. Feature competition indicated that the most informative stance-indexed descriptors were concentrated in early and early-mid stance, while source-study holdout and sensor-perturbation analyses supported the robustness of the representation. These findings indicate that stance-indexed AP-COP retains discriminative information that is not readily recovered by broader engineered gait descriptors, supporting compact and interpretable representations for machine-learning analysis of pathological gait.

0.27

Silhouette-Based Gaitomics for Frailty Assessment in Older Adults

cs.CV ·2026-10-28 ·Laura McDaniel, Ryan Roemmich, Crystal Szczesny, Peter Abadir, Rama Chellappa +1 more
similarity 0.59
Abstract

Walking offers a window into physical function that may support interpretable video-based frailty assessment. We developed silhouette-based "gaitomics" to connect frailty predictions with measurable patterns of body configuration and movement. In 66 older adults assessed using the Fried Frailty Phenotype, standardized silhouettes and gait energy images yielded 90 descriptors of shape, temporal variation, motion, and texture. Minimum redundancy maximum relevance selection using the mutual information difference criterion prioritized informative features while limiting redundancy. Each classifier was evaluated using nested stratified cross-validation with five outer and three inner folds at the participant level, with feature ranking and feature-count selection confined to training partitions. Shapley additive explanations examined contributions to held-out predictions. Bilateral silhouette difference led the aggregate feature-selection rankings for three-class classification and both comparisons involving frail participants. Attribution profiles differed across tasks, with texture and consecutive-frame silhouette differences prominent in three-class classification. Among classifier-specific evaluations, CatBoost achieved the highest mean three-class micro-AUC of 0.647 \pm 0.085. Leading pairwise mean micro-AUCs were 0.833 \pm 0.249 for frail versus nonfrail, 0.765 \pm 0.168 for frail versus prefrail, and 0.554 \pm 0.129 for prefrail versus nonfrail classification. These findings connect model predictions to explicit gait characteristics while revealing task-dependent feature priorities and limited separation of prefrail and nonfrail participants. The framework provides an interpretable basis for further investigation, with larger independent studies needed to establish reliability and clinical relevance.

0.32

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.59
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.59
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.58
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23

Attribute-Centric Vision-Language Alignment for Fine-Grained Gait Understanding

cs.CV ·2026-10-10 ·Saihui Hou, Chenye Wang, Wenpeng Lang, Qiannan Guo, Zhengxiang Lan +3 more
benchmark similarity 0.58
Abstract

Walking sequences reveal human-interpretable attributes related to body structure, posture, and motion. Gait attribute recognition provides a concrete route to fine-grained gait understanding by predicting these attributes. However, existing benchmarks provide limited fine-grained annotations, while classifier-based gait attribute recognition methods typically represent candidate classes through learned output weights rather than directly matching visual evidence with textual class representations. To address the annotation gap, we present RA-GAR, a large-scale, richly annotated multimodal benchmark for gait attribute recognition, containing 1,001 subjects, 242,729 walking sequences, and annotations for 15 static and motion gait attributes. We further propose Gait-VL, an attribute-centric vision-language alignment framework that recognizes gait attributes by matching attribute-specific multi-frame visual evidence with textual class prototypes. On the visual side, attribute-specific learnable queries aggregate RGB features across spatial locations and frames into per-attribute visual embeddings. On the language side, diverse descriptions expanded by a large language model are combined with context about relevant body regions to construct textual class prototypes. Beyond attribute recognition, we evaluate the transferability of the attribute-pretrained visual encoder by using it to replace generic upstream large vision models in identityoriented gait recognition pipelines; attribute pre-training uses no identity classification or metric-learning objectives. Experiments demonstrate state-of-the-art attribute recognition performance on RA-GAR and consistent improvements in downstream identity recognition across multiple pipelines and benchmarks, supporting the effectiveness and transferability of attribute-centric gait representation learning.

0.12