CS Paper Radar

Contactless gait-derived features as candidate digital biomarkers of depression severity in adolescents

Shuai Liu, Xiang Li, Guangxin Dai, Mengyuan Yu, Wenkong Wang, Hanchi Liu, Jiahui Niu, Yujie Nie, Yumei Wang, Xin Ma, Lizhou Fan

eess.SP ·submitted 2026-10-13 15:06 UTC · v1

Abstract

Timely assessment of depression severity in adolescents is essential for guiding clinical care, yet conventional evaluations rely on episodic clinical assessments and symptom rating scales. Contactless gait analysis offers a potentially scalable approach to capturing objective behavioral features associated with depression. Here, we introduce the Long-Distance 3D Adolescent Depression Gait Dataset (LD3D-ADG), comprising depth-sensor gait recordings from 119 adolescents at a single center, including 39 healthy controls, 41 with mild depression, and 39 with moderate-to-severe depression. We developed UMLPA-GCN, a graph convolutional network that models spatiotemporal gait dynamics across three anatomically defined skeletal partitions. In participant-independent five-fold cross-validation, UMLPA-GCN achieved 75.63% classification accuracy, a macro-F1 score of 75.52%, and a macro-area under the receiver operating characteristic curve of 0.839 (95% confidence interval, 0.779--0.899). Class-specific recall was 87.18%, 63.41%, and 76.92% for healthy controls, mild depression, and moderate-to-severe depression, respectively. At the participant level, reduced arm swing, slower pelvic movement, restricted joint range of motion, and greater arm-swing asymmetry were identified as leading potential digital biomarkers contributing to depression severity assessment, associated with higher 17-item Hamilton Depression Rating Scale scores. These findings provide proof-of-concept evidence for contactless digital depression severity stratification in adolescents. Further external and prospective validation is needed to establish their utility for longitudinal monitoring and timely clinical assessment.

Closest papers

Nearest neighbours by meaning across the whole index.

3D Digital Twin Visualization of Multiclass GRF-Based Gait Disorder Classification

cs.LG cs.AI ·2026-09-11 ·Nayoung Son, Minwoo Shin
code/datahot direction similarity 0.66
Abstract

Automated gait analysis requires accurate classification and interpretable outputs. We propose an integrated framework for classifying healthy gait and multiple musculoskeletal impairment groups using bilateral ground reaction force (GRF) and center-of-pressure (COP) signals. The signals were normalized over the stance phase and standardized using training-set statistics. The model achieved a validation accuracy of 99.00\% and a test accuracy of 90.07\% under a session-level split. Class-specific $ε$-LRP identified positive and negative contributions across both sides, multiple signal components, and different stance phases. Separately, the processed GRF signals and model predictions were synchronized within a Blender-based 3D visualization, enabling sample-level inspection of gait trials and classification results. The proposed framework integrates classification, explainability, and 3D visualization to improve model transparency. The source code is available in the following repository: https://github.com/nyoico/grf-gait-3d-visualization.git

0.44

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.66
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13

Single-Stream Multi-Feature Fusion with Temporal Robustness for Gait Emotion Recognition

cs.CV ·2026-09-10 ·Shirong Lyu, Silu Quan, Yixuan Ding, Chengpeng Wang
published similarity 0.63
Abstract · Accepted at the 35th International Conference on Artificial Neural Networks (ICANN 2026)

3D skeleton-based gait emotion recognition faces high annotation costs, data scarcity, and poor generalization on heterogeneous data. This paper proposes SV-GCN, a single-stream multi-feature fusion framework with temporal invariance. We introduce intra-frame relative motion features to eliminate frame-rate sensitivity and embed heterogeneous cues at shallow layers, enabling early fusion without multi-stream complexity. For variable-length sequences, we design a global mask-guided valid-frame spatio-temporal graph convolution module, introducing frame-rate insensitivity for the first time in this domain. On the E-Gait dataset, our method achieves performance comparable to state-of-the-art while demonstrating strong generalization across varying sequence lengths and frame rates, offering a viable pathway for pre-training on large-scale skeleton-based action recognition datasets.

0.32

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

cs.CV ·2026-09-08 ·Soroush Mehraban, Xin Lei Lin, Vida Adeli, Majid Mirmehdi, Amirhossein Dadashzadeh +3 more
benchmarkcode/data similarity 0.63
Abstract · Project Page: https://soroushmehraban.github.io/SynthGait-19k/

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset containing 19,272 walking videos derived from 6,427 MoCap sequences across 437 subjects, with paired SMPL motion and annotations for six gait parameters. To construct the dataset, we develop Gait2Vid, which unifies heterogeneous MoCap recordings through SMPL and synthesizes diverse RGB walking videos under controllable viewpoints and scene appearances. We assess the generated videos for consistency with their conditioning gait kinematics and validate extracted gait events against force-platform measurements. Using SynthGait-19K, we benchmark direct RGB, pose-based, biomechanical, and human-mesh-recovery approaches and analyze viewpoint, training-data scale, and synthetic-to-real domain shift. We also introduce GaitXFormer as a direct RGB reference model for estimating gait parameters. Synthetic supervision transfers effectively to real videos across both GaitXFormer and a pose-based architecture, demonstrating utility across different representations. We further find that spatial gait parameters are more sensitive to visual domain shift and that improved HMR reconstruction alone does not necessarily translate to improved downstream gait estimation.

0.34

Unified Framework with Convex-Concave Decomposition and Sparse Topological Learning for Skeleton-Based Clinical Assessment

cs.CV cs.AI ·2026-11-07 ·Quang-Anh N. D., Duc Pham Minh, Minh-Anh Nguyen, Hien Quang Kha, Manh Hung Ha +2 more
similarity 0.61
Abstract

Skeleton-based rehabilitation assessment faces fundamental limitations of fixed topologies which cannot model compensatory patterns, uniform joint treatments overlook clinically important deviations, and lack of geometric understand- ing. We propose Concave-Convex Decomposition Sparse Topological Graph Convolutional Network (CC2-STG), a multi-stream model that combines geo- metric decomposition, sparse feature learning, and adaptive topology. Our framework decomposes joint relationships into complementary convex-concave distance functions to model both local and global movement characteristics, with sparse regularization with proximal optimization selecting clinically relevant geo- metric features, while multi-scale topological analysis captures non-anatomical joint dependencies in pathological movements. Experiments on the KiMoRe and UIPRMD datasets validate the effectiveness of our approach, achieving state-of-the-art performance on clinical pathological movement assessment.

0.23

Autonomous Telerehabilitation via Skeletal Motion Prediction and Joint-Level Performance Assessment

cs.CV cs.LG ·2026-08-12 ·Lara Pereira, João Ruivo Paulo, Pedro Santos, Paulo Peixoto
published similarity 0.61
Abstract · Accepted at IEEE RO-MAN2026

Autonomous rehabilitation systems must not only recognize human motion but also provide structured feedback to support users without continuous therapist supervision. This paper presents a telerehabilitation pipeline that integrates skeleton-based exercise quality assessment and short-term motion prediction into a two-module system operating on marker-free RGB video. A self-attentive Bidirectional LSTM performs exercise quality classification using MMD-NCA metric learning, while a graph-based motion prediction module computes per-joint position errors between predicted and observed poses, generating spatially localized deviation signals. Each module is evaluated independently on established benchmarks: the classifier achieves 96.45% mean-class accuracy on squat sequences from the PROZIS dataset, and the adopted STARS predictor achieves a mean MPJPE of 75.8 mm at 560 ms on Human3.6M, outperforming graph and recurrent baselines across all prediction horizons. The framework is designed for eventual deployment in assistive robotics and home-based rehabilitation contexts; end-to-end integration and clinical validation are important directions for future work. By combining motion recognition and prediction in a single system, this work contributes a step toward autonomous, feedback-driven telerehabilitation, for more accessible and scalable rehabilitation solutions.

0.23

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.60
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

NeuroPath: Brain-Inspired Dual-Pathway Graph Convolutional Networks for Skeleton-Based Action Recognition

cs.CV ·2026-08-18 ·Kanglei Zhou, Ruizhi Cai, Hubert P. H. Shum, Frederick W. B. Li, Xiaohui Liang
published similarity 0.59
Abstract · Accepted to Pattern Recognition

Skeleton-based action recognition aims to recognize human actions from sequences of human joint coordinates. Most existing Spatial-Temporal Graph Convolutional Networks (STGCNs) have achieved promising results by modeling skeletal structures with implicit spatial-temporal representations. However, our empirical study reveals a clear performance imbalance across different skeletal modalities, indicating that implicitly coupling spatial and temporal information limits the full exploitation of complementary structural and motion cues. Inspired by the ventral and dorsal pathways in human perception, we propose Dual-Pathway Graph Convolutional Networks (NeuroPath), which adopt a dual-pathway architecture for separate yet collaborative modeling of spatial and temporal information. Specifically, transformation units first convert the input into pathway-specific skeletal representations, allowing each pathway to focus on complementary aspects of human motion. To further capture coordinated joint behaviors and their interrelationships, we introduce a group graph convolution block that dynamically identifies key body parts and models their spatial-temporal dependencies. In addition, inter-pathway dynamic fusion modules integrate complementary inter-modal information across pathways, facilitating higher-level semantic interpretation of actions. Extensive experiments on Kinetics Skeleton 400, NTU RGB+D 60, and NTU RGB+D 120 demonstrate consistent performance improvements, validating the effectiveness of dual-pathway spatial-temporal modeling for skeleton-based action recognition.

0.41