CS Paper Radar

PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking

Kaijie Qi, Yuehan Wang, Kaiming Xu, Chong Li, Jiakuo Yu

cs.RO ·submitted 2026-09-30 02:47 UTC · v1

Abstract

Human-aware exoskeleton walking requires reconstructing gait, tracking diverse motions under dynamic constraints, and preserving human timing. We present PhaseSync-Exo, which combines two-IMU CNN-Transformer reconstruction, factorized amplitude-cadence retargeting with curriculum-trained recurrent control, and a human-clock-anchored adapter (HCA). HCA combines human-clock attraction with robot-relative feedback to adjust reference rate while preserving forward progression and continuity. The reconstruction module achieves a mean absolute error (MAE) of 3.24 degrees on a held-out recording, and the frozen tracking policy completes 356 of 357 amplitude-frequency trials. Two complementary dynamic comparisons isolate HCA's timing benefit without retraining. Against robot-relative correction, HCA reduces human-clock phase MAE from 95.55 degrees to 10.99 degrees, limiting reference drift. When human and delivered phases initially differ, it reduces phase MAE from 72.02 degrees to 13.90 degrees versus fixed-clock continuation. Compared with immediate phase reset, HCA reduces transient reference-tracking hip RMSE by 22.7% without reference jumps. All 420 timing rollouts complete without falls. These simulation results support continuous phase acquisition and sustained alignment to an independent human clock.

Closest papers

Nearest neighbours by meaning across the whole index.

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

cs.RO ·2026-09-14 ·Hyungseok Ryu, Pilwon Hur
top venue similarity 0.69
Abstract · 11 pages

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

0.36

Sparse Calibration-Based Personalization of Kernel-Based Gait Phase and Speed Estimation Using Wearable IMUs

cs.RO ·2026-10-02 ·Myeongju Cha, Pilwon Hur
similarity 0.68
Abstract · 6 pages, 4 figures, The 26th International Conference on Control, Automation, and Systems (ICCAS 2026)

This paper presents sparse calibration-based personalization for kernel-based gait phase and walking speed co-estimation from wearable inertial measurement units (IMUs). A 28-speed reference library was constructed from bilateral thigh and shank trajectories in a 20-subject locomotion dataset. Rather than directly applying population-average kernels, the method combines a user-specific baseline estimated from three calibration speeds with a principal-component (PC) model of baseline-centered kinematic deviations. Offline validation showed that personalized kernels reduced phase error relative to the population kernel. In a single-participant online pilot evaluation, the personalized kernels produced numerically lower mean phase and speed errors and ran in real time on embedded hardware. However, the speed effect was not significant, and pairwise phase differences did not remain significant after multiple-comparison correction. The pilot evaluation establishes wearable implementation feasibility while indicating reference-to-online dataset mismatch and the need for larger-cohort validation.

0.19

Tread: A Visuo-Inertial Framework for Terrain and Locomotion Context-Aware Gait-Phase and Speed Estimation in Wearable Robotics

cs.RO ·2026-10-13 ·Debadrata Sarkar, Akash Bachhar, Aman Arora
similarity 0.62
Abstract · Supplementary video: A video demonstrating real-time operation of the complete visuo-inertial inference pipeline is available at https://doi…

A wearable assistive robot must continuously estimate terrain, locomotion mode, gait phase, and walking speed. These quantities are commonly addressed by separate, terrain-specific models, with datasets rarely collected under a common protocol. This paper presents a visuo-inertial framework that connects these estimates through a causal pipeline using a chest-mounted camera and four lower-limb inertial measurement units (IMUs). Anticipatory Terrain Perception (ATP) classifies incoming terrain with 96.3% accuracy and anticipates terrain transitions by 1.46 s on average. Terrain-Aware Locomotion Mode Identification (TALMI) achieves 93.7% and 98.8% accuracy for its level-ground and stairs experts respectively, with mean transition latencies being below 200 ms. The relevant TALMI posterior is retained as a Probabilistic Locomotion Context (PLC) vector and provided to a shared Gait Kinematic Encoder (GKE), which supports 50-Hz bilateral gait-phase estimation and 2-Hz walking-speed estimation. Leave-one-subject-out evaluation yields gait-phase RMSEs of 1.75%, 2.97%, and 4.55% for level walking, stair ascent, and stair descent respectively while estimating speed over 3.5-5.5 km/h with a RMSE of 0.218 km/h. All inertial sensing based models use sensor-fused Euler angles as input rather than raw accelerometer and gyroscope signals, reducing dependence on sensor mounting variation.

0.26

Beyond Kinematic Tracking: Preserving Expressive Characteristics in Humanoid Whole-Body Control

cs.RO ·2026-10-14 ·Lingfan Bao, Hanshang Zhu, Yan Pan, Jincheng Wang, Jingyang Yu +4 more
similarity 0.62
Abstract · Under Review

Whole-body control plays a crucial role in enabling humanoid robots to execute expressive motions. Faithful execution requires preserving both the intended action and its expressive characteristics. Existing whole-body trackers typically balance joint and keypoint tracking with physical stability across diverse motions, but these objectives do not necessarily prioritize the expressive characteristics of each action. Our analysis shows that lower average positional tracking error does not guarantee better preservation of dynamic and postural motion characteristics. To address this gap, we propose a residual learning framework with compensation objectives targeting amplitude, energy, body expansion, body lean, and pelvis height. To concentrate compensation while limiting interference with the underlying tracking behavior, motion-aware gating allocates correction capacity according to body-part activity, preserving larger correction ranges in more active parts and restricting them elsewhere. For each frozen tracker, we train motion-specific residual policies and distill them into a unified policy shared across motion categories. Simulation and physical experiments on the Unitree G1 across eight motion categories demonstrate superior preservation of dynamic and postural motion characteristics compared with the corresponding baselines.

0.12

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
similarity 0.61
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30

A Unified Inertial Encoder for Human and Humanoid Motion

cs.RO ·2026-11-06 ·Yutian Chen, Shibo Zhao, Rocky Duan, Karen Liu, Carmelo Sferrazza +3 more
similarity 0.60
Abstract

Learning humanoid state estimation and language-grounded motion understanding from robot recordings ties training coverage to the robot's motion repertoire. Human motion datasets offer broader coverage, yet transferring this knowledge requires overcoming differences in body geometry, sensing, and physical disturbances. To enable this transfer, we propose a unified inertial encoder whose shared inertial interface uses kinematic IMU synthesis to represent human and humanoid motion at corresponding body sites. Within this common input space, joint training on human and kinematically retargeted humanoid motion combines velocity estimation and motion--text alignment with continuous-time encoding and sensor and motion randomization. The resulting model transfers zero-shot to a physical Unitree G1 without physics simulation, real-robot training trajectories, or fine-tuning, achieving the lowest velocity error among evaluated methods across five datasets, including 0.099m/s on real G1. Its motion-description retrieval also extends to retargeted G1 motion categories observed only in human training, demonstrating how human motion knowledge can support the generalization of humanoid inertial odometry and language-grounded motion understanding.

0.21

A Trainable CPG Framework for Quadruped Locomotion

cs.RO ·2026-10-27 ·Xiyan Liu, Yide Liu, Guoyong Mao, Shaoxing Qu
similarity 0.60
Abstract

We present CPG-ENN, a trainable quadruped locomotion framework that combines explicit neural coordination with learned motion realization. A symmetry-based eight-neuron central pattern generator (CPG) supplies gait rhythms, while a pretrained, leg-shared execution neural network (ENN) maps rhythmic signals and trajectory parameters to joint-angle references without online inverse kinematics. A single feedback policy modulates six physically interpretable trajectory variables. The controller tracks planar velocity and yaw-rate commands across walk, trot, pace, bound, and pronk without gait-specific learned controllers or transitionspecific rewards. Simulation yields 99.39% transition success across all 20 directed gait pairs and all source-target speed combinations from {0.5, 1.0, 1.5, 2.0} m/s. Ablations show high cross-gait transition feasibility without transition exposure; exposure mainly refines gait acquisition and velocity transients. Comparisons with AllGaits and Walk These Ways demonstrate accurate gait-speed regulation, and Unitree Go2 experiments validate five gaits and their transitions.

0.21

ILA: A Transferable Interface-Level Adapter for Compliant Humanoid Motion Tracking

cs.RO ·2026-11-11 ·ZhuoChang Cai, Zihao Yan, Jinxuan Zhu, Yanjie Li, Hao Xiong
similarity 0.60
Abstract · 8 pages, 6 figures

Humanoid motion tracking is fundamental to reproducing human motions on humanoid robots and serves as an important tool for teleoperation and motion data collection. However, directly tracking reference motions can be unsafe in constrained environments or during physical human--robot interaction, motivating the need for compliant motion tracking. We present ILA, an Interface-Level Adapter for compliant humanoid motion tracking without dedicated interaction sensors. ILA adapts motion references from the robot's observation history, allowing the robot to respond to physical guidance while preserving the capabilities of a pretrained motion tracker. As an interface-level module, ILA can be directly plugged into different pretrained motion trackers without retraining either the adapter or the tracking policies. ILA is trained entirely in simulation to predict reference corrections induced by physical interaction. We evaluate ILA with three humanoid motion trackers and achieve a 63.6--75.4% reduction in guidance-target error compared with their original policies. Matched simulation studies and hardware experiments further show that ILA improves responsiveness to human guidance while preserving nominal motion-tracking performance. These results demonstrate compliant guidance as a reusable, sensor-free extension to pretrained humanoid motion trackers.

0.08