Sparse Calibration-Based Personalization of Kernel-Based Gait Phase and Speed Estimation Using Wearable IMUs

Myeongju Cha, Pilwon Hur

cs.RO ·submitted 2026-10-02 18:45 UTC · v1

Abstract

This paper presents sparse calibration-based personalization for kernel-based gait phase and walking speed co-estimation from wearable inertial measurement units (IMUs). A 28-speed reference library was constructed from bilateral thigh and shank trajectories in a 20-subject locomotion dataset. Rather than directly applying population-average kernels, the method combines a user-specific baseline estimated from three calibration speeds with a principal-component (PC) model of baseline-centered kinematic deviations. Offline validation showed that personalized kernels reduced phase error relative to the population kernel. In a single-participant online pilot evaluation, the personalized kernels produced numerically lower mean phase and speed errors and ran in real time on embedded hardware. However, the speed effect was not significant, and pairwise phase differences did not remain significant after multiple-comparison correction. The pilot evaluation establishes wearable implementation feasibility while indicating reference-to-online dataset mismatch and the need for larger-cohort validation.

Comment
6 pages, 4 figures, The 26th International Conference on Control, Automation, and Systems (ICCAS 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking

cs.RO ·2026-09-30 ·Kaijie Qi, Yuehan Wang, Kaiming Xu, Chong Li, Jiakuo Yu
similarity 0.68
Abstract

Human-aware exoskeleton walking requires reconstructing gait, tracking diverse motions under dynamic constraints, and preserving human timing. We present PhaseSync-Exo, which combines two-IMU CNN-Transformer reconstruction, factorized amplitude-cadence retargeting with curriculum-trained recurrent control, and a human-clock-anchored adapter (HCA). HCA combines human-clock attraction with robot-relative feedback to adjust reference rate while preserving forward progression and continuity. The reconstruction module achieves a mean absolute error (MAE) of 3.24 degrees on a held-out recording, and the frozen tracking policy completes 356 of 357 amplitude-frequency trials. Two complementary dynamic comparisons isolate HCA's timing benefit without retraining. Against robot-relative correction, HCA reduces human-clock phase MAE from 95.55 degrees to 10.99 degrees, limiting reference drift. When human and delivered phases initially differ, it reduces phase MAE from 72.02 degrees to 13.90 degrees versus fixed-clock continuation. Compared with immediate phase reset, HCA reduces transient reference-tracking hip RMSE by 22.7% without reference jumps. All 420 timing rollouts complete without falls. These simulation results support continuous phase acquisition and sustained alignment to an independent human clock.

0.23

Tread: A Visuo-Inertial Framework for Terrain and Locomotion Context-Aware Gait-Phase and Speed Estimation in Wearable Robotics

cs.RO ·2026-10-13 ·Debadrata Sarkar, Akash Bachhar, Aman Arora
similarity 0.66
Abstract · Supplementary video: A video demonstrating real-time operation of the complete visuo-inertial inference pipeline is available at https://doi…

A wearable assistive robot must continuously estimate terrain, locomotion mode, gait phase, and walking speed. These quantities are commonly addressed by separate, terrain-specific models, with datasets rarely collected under a common protocol. This paper presents a visuo-inertial framework that connects these estimates through a causal pipeline using a chest-mounted camera and four lower-limb inertial measurement units (IMUs). Anticipatory Terrain Perception (ATP) classifies incoming terrain with 96.3% accuracy and anticipates terrain transitions by 1.46 s on average. Terrain-Aware Locomotion Mode Identification (TALMI) achieves 93.7% and 98.8% accuracy for its level-ground and stairs experts respectively, with mean transition latencies being below 200 ms. The relevant TALMI posterior is retained as a Probabilistic Locomotion Context (PLC) vector and provided to a shared Gait Kinematic Encoder (GKE), which supports 50-Hz bilateral gait-phase estimation and 2-Hz walking-speed estimation. Leave-one-subject-out evaluation yields gait-phase RMSEs of 1.75%, 2.97%, and 4.55% for level walking, stair ascent, and stair descent respectively while estimating speed over 3.5-5.5 km/h with a RMSE of 0.218 km/h. All inertial sensing based models use sensor-fused Euler angles as input rather than raw accelerometer and gyroscope signals, reducing dependence on sensor mounting variation.

0.26

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

cs.RO ·2026-09-14 ·Hyungseok Ryu, Pilwon Hur
similarity 0.65
Abstract · 11 pages

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

0.20

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.63
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

cs.RO ·2026-10-14 ·Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie +1 more
dataset similarity 0.63
Abstract · 8 pages, 5 figures

Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.

0.26

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.61
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.25

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
similarity 0.61
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.61
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23