CS Paper Radar

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

Shubham Jariwala

cs.CV eess.IV ·submitted 2026-09-09 03:37 UTC · v1

Abstract

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

Comment
5 pages, 1 figure

Closest papers

Nearest neighbours by meaning across the whole index.

ExMR: Extremity Motion Refinement for Monocular Human Motion Capture

cs.CV ·2026-10-19 ·Tom Wehrbein, Bodo Rosenhahn
code/data similarity 0.69
Abstract · Extended version of the 3DV 2026 paper "Improving 3D Foot Motion Reconstruction in Markerless Monocular Human Motion Capture". 17 pages main…

Detailed hand and foot articulation is important for animation and motion analysis, yet remains challenging to recover from monocular video. Recent expressive video methods infer hand articulation from shared whole-body representations. Our conference work suggests that this underexploits local evidence: the Foot Motion Refinement (FootMR) module refines ankle rotations from foot keypoints, improving reconstruction even when the initial estimator receives the same keypoints. We extend this principle to hands with the Hand Motion Refinement (HandMR) module. Because 2D finger keypoints are often missing or unreliable, HandMR combines image features of a pretrained hand reconstruction model with initial arm and hand rotations to refine elbows, wrists, and fingers. We integrate FootMR and HandMR into ExMR (Extremity Motion Refinement), a system for reconstructing 3D body, hand, and foot motion from monocular video. An initial temporal estimator predicts whole-body motion, after which both refiners revisit local evidence to predict residual joint rotations. Experiments on ARCTIC, MOYO, RICH, and MOOF show that ExMR outperforms state-of-the-art methods in hand and foot reconstruction, reducing hand per-vertex error and ankle joint angle error on MOYO by 19% and 18%, respectively, relative to the strongest competitor. Code will be made available for research purposes. Project page: https://twehrbein.github.io/exmr-website/

0.31

Prosthesis-Aware 3D Human Pose Estimation: A Dataset and Benchmark for RSP Users

cs.CV ·2026-09-16 ·Yilin Wen, Kechuan Dong, Fumiya Suginaka, Ken Endo, Yusuke Sugano
top venuebenchmarkdatasetcode/data similarity 0.68
Abstract · ECCV 2026. Project page: https://ut-vision.github.io/RSP3D/

Recovering 3D human body motion from video is important for applications such as rehabilitation assessment and sports performance evaluation. For prosthesis users, this requires capturing both natural body joints and the geometry of the prosthetic device, a challenge that existing methods are not designed to address. Model-based estimators rely on body models trained on non-amputee individuals and cannot represent prosthesis geometry, while model-free methods lack body kinematic priors and are unreliable under occlusion. This challenge is particularly prominent for users of running-specific prostheses (RSPs), where the RSP has a complex curved geometry and moves dynamically during exercise. To fill this gap, we collect RSP3D, the first 3D dataset of RSP users, covering essential daily-life and exercise actions from participants with varied amputation conditions, using a multi-camera marker-based motion capture setup. We formally define the task of prosthesis-aware 3D pose estimation, evaluate representative methods in a zero-shot setting, and confirm their individual limitations. We further propose a hybrid baseline combining model-based body joint estimation with model-free RSP shape recovery, establishing a starting point for future research.

0.50

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

cs.CV ·2026-09-08 ·Soroush Mehraban, Xin Lei Lin, Vida Adeli, Majid Mirmehdi, Amirhossein Dadashzadeh +3 more
benchmarkcode/data similarity 0.68
Abstract · Project Page: https://soroushmehraban.github.io/SynthGait-19k/

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset containing 19,272 walking videos derived from 6,427 MoCap sequences across 437 subjects, with paired SMPL motion and annotations for six gait parameters. To construct the dataset, we develop Gait2Vid, which unifies heterogeneous MoCap recordings through SMPL and synthesizes diverse RGB walking videos under controllable viewpoints and scene appearances. We assess the generated videos for consistency with their conditioning gait kinematics and validate extracted gait events against force-platform measurements. Using SynthGait-19K, we benchmark direct RGB, pose-based, biomechanical, and human-mesh-recovery approaches and analyze viewpoint, training-data scale, and synthetic-to-real domain shift. We also introduce GaitXFormer as a direct RGB reference model for estimating gait parameters. Synthetic supervision transfers effectively to real videos across both GaitXFormer and a pose-based architecture, demonstrating utility across different representations. We further find that spatial gait parameters are more sensitive to visual domain shift and that improved HMR reconstruction alone does not necessarily translate to improved downstream gait estimation.

0.34

Robust Real-Time Monocular Human Pose Estimation with Insole-Based Sensor Fusion

cs.CV cs.AI ·2026-10-14 ·Liang Yu, Tao Zhu, Xiangqing Lu, Wenjian Luo, Liming Chen
similarity 0.66
Abstract

Real-time monocular human pose estimation is an important sensing component for human-centered intelligent systems. While recent camera-based methods have achieved impressive accuracy, fundamental challenges persist, particularly when visual observations are incomplete, such as during lower-body occlusion or short out-of-frame intervals. In these challenging but common scenarios, vision-only systems often struggle to reconstruct physically plausible lower-limb motion and reliable foot-ground contact. Due to the highly unobtrusive and wearable nature of smart insoles, this paper investigates whether simple plantar pressure and acceleration sensors can effectively resolve these visually induced limitations. To systematically investigate this, we first collect a synchronized multimodal dataset and then propose a part-decoupled temporal fusion framework. The proposed model fuses foot-sensing features into the lower-body branch to compensate for incomplete visual evidence, while a lightweight coordinator exchanges information between the upper- and lower-body temporal representations to maintain whole-body consistency. The framework is evaluated with three representative real-time visual backbones based on 2D keypoints, 3D landmarks, and SMPL-based human mesh recovery. We evaluate our framework on three representative real-time visual backbones. Quantitative experiments demonstrate that incorporating simple foot sensors consistently improves pose accuracy, motion smoothness, and gait-related measurements over vision-only baselines, with the most significant gains observed under occlusion and short visual-dropout conditions. Ultimately, our results demonstrate that unobtrusive foot sensing provides vital and complementary physical observability when camera observations are temporarily unavailable.

0.20

CAST: Real-Time Motion Capture for Any Skeleton Topology

cs.CV ·2026-10-10 ·Pu Pang, Zhongfei Qing, Ling-Hao Chen, Songnan Li, Hua Huang +1 more
benchmarkcode/data similarity 0.64
Abstract · 39 pages. Code repository: https://github.com/fankewen/CAST

This paper studies the problem of recovering motion from monocular video, even when the target skeleton topology differs from the subject observed in the video. Although previous methods have made efforts to resolve this problem, they remain vulnerable to joint-rotation errors that are coupled across the skeleton and can propagate along its kinematic hierarchy. To mitigate these errors, we present CAST, a topology-aware motion capture framework that combines learned local rotations with geometric correction guided by predicted global bone directions. Our observability analysis characterizes which rotational components can be constrained by outgoing bone directions. Guided by this analysis, GRACE uses reliability-gated alignment to correct composed orientations in parent-to-child order, leaving unconstrained components to the learned rotation predictor. The motion predictor and correction module are trained jointly with motion-derived supervision, using a frozen image encoder. Experiments under the TopoCap evaluation protocol show that the proposed framework improves motion recovery across different target topologies, including unseen structures. Reference-based cross-skeleton evaluation on a curated Mixamo benchmark and a user preference study further assess transfer to different target structures. A causal CAST-B variant achieves over 51 FPS on a single NVIDIA A100 GPU, with timing covering image encoding and motion prediction. Code repository: https://github.com/fankewen/CAST.

0.50

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.64
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

cs.RO ·2026-09-14 ·Hyungseok Ryu, Pilwon Hur
similarity 0.63
Abstract · 11 pages

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

0.20

Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods

cs.CV physics.med-ph ·2026-09-16 ·Florian Delaplace, Elodie Piche, Frédéric Chorin, Raphael Zory
similarity 0.63
Abstract

Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.

0.33