CS Paper Radar

Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods

Florian Delaplace, Elodie Piche, Frédéric Chorin, Raphael Zory

cs.CV physics.med-ph ·submitted 2026-09-16 13:44 UTC · v1

Abstract

Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.

Closest papers

Nearest neighbours by meaning across the whole index.

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.70
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

Prosthesis-Aware 3D Human Pose Estimation: A Dataset and Benchmark for RSP Users

cs.CV ·2026-09-16 ·Yilin Wen, Kechuan Dong, Fumiya Suginaka, Ken Endo, Yusuke Sugano
top venuebenchmarkdatasetcode/data similarity 0.66
Abstract · ECCV 2026. Project page: https://ut-vision.github.io/RSP3D/

Recovering 3D human body motion from video is important for applications such as rehabilitation assessment and sports performance evaluation. For prosthesis users, this requires capturing both natural body joints and the geometry of the prosthetic device, a challenge that existing methods are not designed to address. Model-based estimators rely on body models trained on non-amputee individuals and cannot represent prosthesis geometry, while model-free methods lack body kinematic priors and are unreliable under occlusion. This challenge is particularly prominent for users of running-specific prostheses (RSPs), where the RSP has a complex curved geometry and moves dynamically during exercise. To fill this gap, we collect RSP3D, the first 3D dataset of RSP users, covering essential daily-life and exercise actions from participants with varied amputation conditions, using a multi-camera marker-based motion capture setup. We formally define the task of prosthesis-aware 3D pose estimation, evaluate representative methods in a zero-shot setting, and confirm their individual limitations. We further propose a hybrid baseline combining model-based body joint estimation with model-free RSP shape recovery, establishing a starting point for future research.

0.50

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

cs.CV ·2026-09-08 ·Soroush Mehraban, Xin Lei Lin, Vida Adeli, Majid Mirmehdi, Amirhossein Dadashzadeh +3 more
benchmarkcode/data similarity 0.65
Abstract · Project Page: https://soroushmehraban.github.io/SynthGait-19k/

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset containing 19,272 walking videos derived from 6,427 MoCap sequences across 437 subjects, with paired SMPL motion and annotations for six gait parameters. To construct the dataset, we develop Gait2Vid, which unifies heterogeneous MoCap recordings through SMPL and synthesizes diverse RGB walking videos under controllable viewpoints and scene appearances. We assess the generated videos for consistency with their conditioning gait kinematics and validate extracted gait events against force-platform measurements. Using SynthGait-19K, we benchmark direct RGB, pose-based, biomechanical, and human-mesh-recovery approaches and analyze viewpoint, training-data scale, and synthetic-to-real domain shift. We also introduce GaitXFormer as a direct RGB reference model for estimating gait parameters. Synthetic supervision transfers effectively to real videos across both GaitXFormer and a pose-based architecture, demonstrating utility across different representations. We further find that spatial gait parameters are more sensitive to visual domain shift and that improved HMR reconstruction alone does not necessarily translate to improved downstream gait estimation.

0.34

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.65
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23

MuyBridge: Mobile Human Center-of-Mass Estimation from Monocular Video via Sparse Fusion

cs.CV ·2026-09-02 ·Aidan Bradshaw, Marco Giordano, David Rode, Andreas Habersack, Elif Basokur +6 more
code/data similarity 0.64
Abstract

The 3D center of mass (CoM) is a primary quantity in the biomechanical analysis of sport, rehabilitation, and clinical movement, yet existing 3D pose tracking, mesh recovery, and multi-view triangulation methods either optimize 3D keypoint accuracy without anatomical constraints or carry compute and capture infrastructure too heavy to deploy where CoM tracking is most useful. As a result, the metric CoM remains difficult for coaches and movement analysts to measure from a single camera where athletes train and compete. In this work, we introduce MuyBridge, an on-device system that estimates the athlete's segmental center of mass trajectory from a single phone camera video stream. MuyBridge couples a compact 2D pose network and a distilled single-step monocular depth network through an analytic metric fusion that uses anatomical and physical priors to anchor the metric CoM, requiring no 3D or task-specific supervision. Evaluated on the athletic movements of AthletePose3D (running, track and field, and figure skating), MuyBridge achieves 33-41 mm vertical CoM error and 2.3-6.6% absolute-relative range error (AbsRel) under a one-time calibration, and produces CoM estimates at the 63 FPS pose-estimation rate using asynchronous 2.86 Hz depth updates on iPhone 15. Code is available at: https://github.com/Abradshaw1/Muybridge

0.34

Impact of Patient Orientation in Single- and Multi-View Camera Environments for AI-based Rehabilitation Monitoring

cs.CV ·2026-09-28 ·Miriama Jánošová, Andreas Lang, Petra Budikova, Jan Sedmidubsky
dataset similarity 0.64
Abstract

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9% over the commonly used 0° frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

0.09

Markerless Pose Estimation for Resistance Training Technique Assessment

cs.CV cs.AI ·2026-08-25 ·Joseph Turner, Jeff Clark, Nawid Keshtmand
similarity 0.63
Abstract

Resistance training can be a high risk activity, and safe form is essential to avoiding injury. Laboratory-based movement analysis provides quantitive technique assessment, yet is not easily accessible. Markerless pose estimation infers body landmarks from images or video without physical markers and could offer a feasible alternative for technique assessment. We present a pose estimation framework to evaluate resistance-training technique from ordinary video footage. Using BlazePose, anatomical landmarks were extracted from squat, bench press, and deadlift videos and converted into joint-angle trajectories, with the squat serving as the primary case study. Trajectories were assessed against a defined reference repetition using root mean square error (RMSE). Results show that the framework recovers meaningful kinematic patterns for the squat and deadlift, enabling quantitative comparison between repetitions and identification of technique variability within a set. Performance depended strongly on camera orientation and visual occlusion, with non-sagittal views distorting 2D joint-angle estimates. The findings demonstrate that markerless pose estimation can support accessible biomechanical assessment outside laboratory environments.

0.31

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
similarity 0.63
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30