CS Paper Radar

Daily listing

2026-10-17 · cs.LG

107 papers first submitted this day (UTC) in cs.LG — Machine Learning. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Robotics, Control & Signals 2

ATLAS: Expert-Guided Sustainable Satellite Backhaul for Off-Grid Wildlife Monitoring

eess.SY cs.LG ·2026-10-17 ·Hao Fang, Miao Zhang, Haoyuan Zhao, Long Chen, Yi Ching Chou +3 more
published
Abstract · Accepted at the ACM SIGOPS Annual Technical Conference (ATC 2026)

Remote wildlife monitoring increasingly depends on high-fidelity cameras and sensors deployed far from grid power and terrestrial networks. Low Earth orbit satellite links can provide connectivity in these settings, but their high power draw and variable bandwidth, combined with intermittent on-site solar harvesting, make continuous backhaul infeasible. Current systems therefore filter at the edge, with motion triggers that waste limited energy and bandwidth on environmental artifacts, or fixed vision models that cannot follow evolving expert objectives. We present \textsc{ATLAS}, an expert-guided edge-to-cloud system that treats satellite backhaul as a scarce resource for off-grid wildlife monitoring. \textsc{ATLAS} uses foundation models to compile natural-language expert intent into semantic scoring logic, combines semantic relevance with environmental and energy state, and uses a constrained reinforcement-learning scheduler to decide which clips to upload and when. As a representative case study, we deployed \textsc{ATLAS} for over six months across 18 off-grid salmon-monitoring river sites. \textsc{ATLAS} achieves a mean clip-selection accuracy of $87.4\%$, exceeding mean baseline accuracy by $26.4$ percentage points, while maintaining near-continuous operation through low-solar periods in which baselines incur 16.0\% downtime.

0.26

Is User Calibration Still Necessary for Continuous Myoelectric Control? A Closed-Loop Comparison of Calibration-Free Controllers

eess.SP cs.HCcs.LG ·2026-10-17 ·Amir Reza Hariri, Kevin B. Englehart, Erik Scheme
Abstract · Submitted to IEEE Transactions on Neural Systems and Rehabilitation Engineering

The need for user-specific calibration remains an often-cited barrier to widespread adoption of myoelectric control. Cross-user models trained on large multi-user datasets can now recognize gestures from unseen users without calibration, but they have been evaluated almost exclusively offline, leaving open whether calibration is still needed in closed-loop control. This study compared six calibration-free controllers, trained on 306 users of the EMG-EPN-612 dataset and used without any calibration data from the test participant, against three calibrated controllers in a closed-loop Fitts' law target-acquisition task with sixteen participants. The calibrated controllers achieved higher offline balanced accuracy (90.6% against 73.1% for the best controller of each paradigm), but completion rates did not differ significantly between paradigms, and the highest completion rate was achieved by a calibration-free controller. Calibrated controllers moved faster on successful acquisitions, partly because of their individually fitted speed mappings, though not significantly after correction for multiple comparisons. However, every calibration-free controller produced more direct and stable trajectories than every calibrated controller, even after adjusting for cursor speed. Offline accuracy did not predict completion rate across controllers or within participants, and across paradigms higher offline accuracy was associated with poorer trajectory quality in 15 of 16 participants. Without any calibration data from the end user, a model trained across a large population matched calibrated control in completion rate and exceeded it in trajectory quality. The offline accuracy gained through calibration should therefore not be taken as evidence of a closed-loop benefit.

0.23