CS Paper Radar

Is User Calibration Still Necessary for Continuous Myoelectric Control? A Closed-Loop Comparison of Calibration-Free Controllers

Amir Reza Hariri, Kevin B. Englehart, Erik Scheme

eess.SP cs.HCcs.LG ·submitted 2026-10-17 18:09 UTC · v1

Abstract

The need for user-specific calibration remains an often-cited barrier to widespread adoption of myoelectric control. Cross-user models trained on large multi-user datasets can now recognize gestures from unseen users without calibration, but they have been evaluated almost exclusively offline, leaving open whether calibration is still needed in closed-loop control. This study compared six calibration-free controllers, trained on 306 users of the EMG-EPN-612 dataset and used without any calibration data from the test participant, against three calibrated controllers in a closed-loop Fitts' law target-acquisition task with sixteen participants. The calibrated controllers achieved higher offline balanced accuracy (90.6% against 73.1% for the best controller of each paradigm), but completion rates did not differ significantly between paradigms, and the highest completion rate was achieved by a calibration-free controller. Calibrated controllers moved faster on successful acquisitions, partly because of their individually fitted speed mappings, though not significantly after correction for multiple comparisons. However, every calibration-free controller produced more direct and stable trajectories than every calibrated controller, even after adjusting for cursor speed. Offline accuracy did not predict completion rate across controllers or within participants, and across paradigms higher offline accuracy was associated with poorer trajectory quality in 15 of 16 participants. Without any calibration data from the end user, a model trained across a large population matched calibrated control in completion rate and exceeded it in trajectory quality. The offline accuracy gained through calibration should therefore not be taken as evidence of a closed-loop benefit.

Comment
Submitted to IEEE Transactions on Neural Systems and Rehabilitation Engineering

Closest papers

Nearest neighbours by meaning across the whole index.

Comparing Temporal Deep Learning Architectures for Discrete Cross-User Myoelectric Control

cs.HC ·2026-10-27 ·Ethan Eddy, Evan Campbell, Scott Bateman, Erik Scheme
dataset similarity 0.62
Abstract

The recognition of dynamic gestures via discrete myoelectric control is becoming an attractive input modality for event-based human-machine interaction. While recent work suggests that discrete cross-user models are possible (i.e., no calibration data is required from the end user), few have evaluated techniques to optimize these systems and their generalizability to new randomly prompted data simulating real-world discrete control is relatively unknown. Using the 612-user EMG-EPN dataset, this work benchmarks five temporal deep-learning approaches, evaluates the tradeoff between performance and model complexity, and compares hand-crafted and machine-learned feature extraction techniques. The CNN-GRU achieved the best accuracy of 93% when tested on 184 previously unseen users. These models were then evaluated on a different, more realistic, unsegmented dataset, wherein users were randomly prompted to elicit discrete gestures during a continuous data collection. This dataset was recorded five years apart and in a separate country from the data used to train the original model. Results show that the cross-user results scale to this new dataset (accuracies of 96%) even though no feedback was given to users during the elicitation of gestures. These findings highlight the exciting potential of discrete zero-shot cross-user myoelectric control and offer valuable insights for the continued advancement of this promising technology.

0.16

Myoelectric Control for Upper-Limb Exoskeletons: A Decoder-Shaper-Controller Framework, Design Guidelines, and Future Directions

cs.RO ·2026-11-02 ·Davide Costanzi, Eldison Dimo, Emanuele Feola, Mario Sedilesu, Francesco Pascucci +1 more
similarity 0.59
Abstract · 19 pages, 3 figures. Review paper

Myoelectric Control Systems (MCSs) enable voluntary control of wearable robots through muscle activity. However, intention decoding, assistance shaping, and low-level actuator control are often not explicitly distinguished, making their contributions difficult to evaluate and compare. This review introduces a functional decoder-shaper-controller framework for continuous myoelectric control of upper-limb exoskeletons. The decoder estimates an intention-related variable from surface electromyography (sEMG), the shaper maps it to a control reference according to an assistance policy, and the controller realizes that reference through actuator control. This decomposition separates intention estimation from assistance-policy design and enables comparison of heterogeneous architectures. Representative approaches are critically examined in terms of module design, calibration, and evaluation. The analysis highlights that the shaper, despite determining the magnitude and shape of assistance, lacks established design and tuning methodologies and is often embedded within the decoder or controller. Key open issues include inconsistent reporting of assistance levels, limited use of interaction-aware stability and passivity tools, and insufficient validation across degrees of freedom, users, and tasks. Building on these findings, this review provides design guidelines for systematic module-wise tuning and identifies future research priorities to bridge the gap between accurate intention decoding and safe, effective, and generalizable assistance under real-world operating conditions.

0.16

A generalist policy for muscle-driven control across individual musculoskeletal models

cs.RO ·2026-10-27 ·Bozhao Wang, Yinglei Zhu, Zhengqing Li, Zhiyuan Zhang, Weiming Kang +5 more
similarity 0.58
Abstract · 17 pages, 7 figures. Project website: https://woodater-thu.github.io/MyoAcross/ Bozhao Wang and Yinglei Zhu contributed equally to this work

Differences in musculoskeletal morphology challenge policy reuse across individual models. Here we present MyoAcross, a framework that combines individual musculoskeletal model construction, morphology-conditioned policy learning and virtual model augmentation to enable muscle-driven reference-motion tracking without individual fine-tuning. Across 31 held-out individual models, MyoAcross achieves 99.24% completion and reduces tracking error by 22.60% relative to an unconditioned multilayer perceptron. Policy reuse extends to models of 22 held-out individuals constructed from single-image shape estimates, measured height and body mass, and, with asymmetry augmentation, to models with unilateral lower-limb shortening. Comparisons with measurements from 120 additional individuals show agreement in vertical ground reaction force waveforms and channel-dependent agreement between simulated muscle activations and electromyography. These results establish a common control framework for comparative simulations of movement across individual musculoskeletal models.

0.38

Comparing Hand and Controller Avatars with Hand Tracking and Controller-Based Interaction

cs.HC ·2026-09-18 ·Natalia Ocampo, J. Felipe Gonzalez, Robert J. Teather
top venuehighly cited similarity 0.57
Abstract

Previous research suggests that the congruency between common VR input devices - such as controllers or hand tracking - and their visual representations (e.g., hand or controller avatars) influences user experience and performance. However, the specific effects of input-avatar combinations remain underexplored. We study the effects of common input devices (hand tracking and controllers) and visual representations (hand and controller avatars) on performance and perceived success in target acquisition tasks. We included both grasping and pinching gestures across 16 combinations of input, avatar, and target size. Results indicate that hand tracking benefits from any form of visual representation - even when mismatched - achieving up to 5.8% greater accuracy compared to having no avatar, likely due to its reliance on visual feedback in the absence of a physical prop. Controllers were generally preferred and offered faster task completion. However, mismatched avatars had a stronger negative effect with controllers, particularly when the virtual gesture did not align with the physical action, leading to a 5.6% drop in accuracy compared to the matched condition - suggesting that inaccurate feedback can be more disruptive than having no avatar feedback at all.

0.65

Do Personal Adapters Carry Over Across Sessions? Separating Personal From Population Gains When Calibrating EEG Foundation Models for Motor Imagery

cs.LG eess.SPq-bio.NC ·2026-09-28 ·Xilin Tao, Kani Chen
similarity 0.57
Abstract · 8 pages main text + 9 pages supplementary material (appended). v2: substantially revised and retitled; adds cross-session experiments for CB…

Every new user of a motor imagery brain-computer interface must be calibrated, and users typically return on different days. A common approach with electroencephalography (EEG) foundation models fits a small personal adapter on a frozen backbone, but evaluations are usually confined to one session and rarely separate the user's own contribution from that of the population model. We quantified personal adapters with two paired contrasts, the net gain of a user's own adapter over the population model and its advantage over adapters fitted to other users, for three frozen foundation models (CBraMod, REVE and LaBraM). In 235 held-out subjects from three datasets, same-session calibration produced a positive net gain in all nine model and dataset combinations (means of 1.5 to 5.4 percentage points), and the gain remained positive when population training was quadrupled. In 54 two-session subjects, adapters fitted on the first day still improved on the population model on the second day by 1.31 points for REVE and 1.64 points for LaBraM (Holm-adjusted p<0.01), retaining 61% and 83% of the gain from same-day recalibration, whereas the gain for CBraMod was 0.04 points and indistinguishable from zero. Same-day recalibration gave the highest mean accuracy for all three models, and adding 5 to 20 second-day labels to the first-day adapter mostly fell short of it. Whether personal adapters carry over across sessions therefore depends on the model and must be tested per model, and personalization should be reported against both a population reference and exchanged parameters, including across sessions.

0.33

GIFT: Glove-Inferred Force Transfer: Force-Aware Human-to-Robot Skill Transfer from a Wearable Sensing Glove to a Robot Hand Without Tactile Sensors

cs.RO ·2026-09-12 ·Tzach Sarusi
code/data similarity 0.54
Abstract · 7 pages, 5 figures, 1 table. Project page: https://tzahsarusi.github.io

Human-to-robot skill transfer from sensing gloves has so far relied on shared hardware: the same tactile glove worn by the demonstrator and the robot, or a learned alignment between two tactile sensors. We present GIFT (Glove-Inferred Force Transfer), a pipeline in which the interface between human and robot is a physical unit rather than a shared sensor: fingertip force is measured in newtons on the human side and estimated in newtons on the robot side. A wearable glove records finger flexion, calibrated fingertip force, and wrist orientation, while a head-mounted camera records the demonstration; no robot is present. At deployment, the robot estimates force from actuator-current residuals relative to a free-space baseline, through a calibrated mapping to newtons, so any position-controlled hand that reports motor current can serve as the deployment platform. The policy uses a glove-space state and predicts finger-position targets; the robot enters only through two calibrated adapters, a retargeting decoder and a force estimator. We evaluate GIFT on a cup grasp-and-hold task with two action-chunking policies trained on the same demonstrations, with fingertip-force inputs retained in one and zeroed in the other. In a 50-rollout evaluation with sample size and metrics fixed before scoring, both policies succeeded in all 25 rollouts. The median of the per-rollout hold-phase grip-force estimates was 53% lower with force inputs: 1.20 N versus 2.55 N (one-sided Mann-Whitney U, p<0.0001). In an observation ablation, a vision-only policy achieved 0/15 grasps, policies given hand-command state acquired the grasp, and the force inputs determined how hard the policy held. A force channel measured on the human hand thus transfers to a robot hand with no tactile hardware, through a retargeting map from five glove channels to seven robot actuators, with no sensor shared between the two.

0.32

PalmSpace: Towards a Versatile On-Palm Interaction Space through Unified Touch Modeling

cs.HC cs.CV ·2026-10-07 ·Chentao Li, Mingze Gao, Runze Sun, Zhaoguo Wang, Jianjiang Feng +1 more
similarity 0.54
Abstract · Preprint. Initial version

As smart glasses and lightweight MR devices become increasingly practical, input remains a key challenge. The bare palm is an always-available, tactile, and proprioceptively accessible surface, but it has neither an explicit coordinate system nor embedded touch sensing. Prior on-palm systems typically expose isolated touch events, discrete regions, continuous trajectories, or task-specific gestures, limiting the palm's ability to support precise selection and gesture manipulation through a common input representation. We present PalmSpace, a wrist-worn infrared system that exposes mode-aware, body-referenced absolute input on the bare palm without per-user sensing calibration. At the interaction level, PalmSpace jointly represents contact occurrence, interaction mode, and palm-referenced absolute location; at the model level, it learns these coupled outputs through a shared real-time representation. In leave-one-participant-out evaluation with 17 participants, PalmSpace achieved 6.7 mm mean localization error, 98.9% contact detection accuracy, and 96.7% F1 for four-class interaction-state recognition. User studies further demonstrated absolute pointing and dragging, eyes-free digit input, and representative multi-finger controls including scrolling and pinch-based map manipulation. These results show that a morphologically variable bare palm can function as a transferable, mode-aware interaction surface.

0.17

EMGBlend: Heterogeneity-Aware Self-Supervised Pretraining for Gesture and Force Decoding

cs.LG cs.AI ·2026-09-22 ·Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
code/data similarity 0.54
Abstract

Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pretraining can misalign channel semantics, introduce spectral targets that some devices cannot observe, and let large or high-channel-count datasets dominate learning. We introduce EMGBlend, a self-supervised framework designed around these differences. It combines shared channel patches with geometry-aware attention, restricts spectral targets to each recording's supported frequency band, and balances exposure across data sources. We pretrain a 109M-parameter model on 11 public EMG sources and evaluate it on gesture recognition, continuous-force regression, and contact classification. EMGBlend consistently outperforms matched random initialization and waveform reconstruction controls. Fixed-budget source controls show that multi-source pretraining improves gesture recognition and remains competitive for force decoding. Ablations confirm that geometry, band-aware targets, and source balancing each contribute to transfer, although cross-person NinaPro force estimation remains difficult. Overall, EMGBlend shows how heterogeneous EMG datasets can be combined through explicit mechanism design rather than simple concatenation. Code is available at https://github.com/tamanano/EMGBlend

0.25