CS Paper Radar

Myoelectric Control for Upper-Limb Exoskeletons: A Decoder-Shaper-Controller Framework, Design Guidelines, and Future Directions

Davide Costanzi, Eldison Dimo, Emanuele Feola, Mario Sedilesu, Francesco Pascucci, Andrea Calanca

cs.RO ·submitted 2026-11-02 16:41 UTC · v2

Abstract

Myoelectric Control Systems (MCSs) enable voluntary control of wearable robots through muscle activity. However, intention decoding, assistance shaping, and low-level actuator control are often not explicitly distinguished, making their contributions difficult to evaluate and compare. This review introduces a functional decoder-shaper-controller framework for continuous myoelectric control of upper-limb exoskeletons. The decoder estimates an intention-related variable from surface electromyography (sEMG), the shaper maps it to a control reference according to an assistance policy, and the controller realizes that reference through actuator control. This decomposition separates intention estimation from assistance-policy design and enables comparison of heterogeneous architectures. Representative approaches are critically examined in terms of module design, calibration, and evaluation. The analysis highlights that the shaper, despite determining the magnitude and shape of assistance, lacks established design and tuning methodologies and is often embedded within the decoder or controller. Key open issues include inconsistent reporting of assistance levels, limited use of interaction-aware stability and passivity tools, and insufficient validation across degrees of freedom, users, and tasks. Building on these findings, this review provides design guidelines for systematic module-wise tuning and identifies future research priorities to bridge the gap between accurate intention decoding and safe, effective, and generalizable assistance under real-world operating conditions.

Comment
19 pages, 3 figures. Review paper

Closest papers

Nearest neighbours by meaning across the whole index.

A Human-in-the-Loop Comparison of Proportional Control and Adaptive Gravity Compensation in Elbow EMG-Driven Exoskeletons

cs.RO ·2026-10-19 ·Francesco Pascucci, Eldison Dimo, Davide Costanzi, Mario Sedilesu, Andrea Calanca
similarity 0.71
Abstract · 8 pages, 10 figures, 4 tables

Electromyography (EMG)-driven control enables wearable robots to assist users based on their neuromuscular activity. Upper-limb exoskeletons typically rely on proportional myoelectric control (PMC), which amplifies user effort but may compromise stability at high assistance levels. EMG-driven adaptive gravity compensation (AGC) offers a promising alternative, counterbalancing gravitational torques while continuously adapting to neuromuscular activity. However, these approaches have not been systematically compared in a human-in-the-loop setting. This study evaluates five control algorithms: two PMC strategies at different assistance levels, a purely integral AGC (AGC-PI), a kinematics- and acceleration-aware model-based (MB) AGC (AGC-AW), and a novel MB AGC approach based on Recursive Least Squares (AGC-RLS) for online payload estimation. Fourteen healthy participants performed target-reaching tasks using an active elbow exoskeleton under 0 kg and 2 kg loading conditions. Performance metrics included muscular activity, movement accuracy, task efficiency, and subjective workload. PMC exhibited a trade-off between physical effort and task performance: low assistance levels required greater physical effort under load, whereas high gains impaired task execution. AGC-PI reduced agonist activity but induced antagonist activation. In contrast, both model-based AGC approaches effectively compensated for external payloads, reducing physical and cognitive demands while improving movement accuracy and completion time.

0.20

Recursive Self-Improvement of Exoskeleton Assistance Policies through Human-in-the-Loop Feedback

cs.RO ·2026-11-01 ·Muyuan Ma, Shuo Jiang, Lijun Han, Xinpan Meng, Zhenghua Ma +3 more
hot direction similarity 0.67
Abstract

To reduce reliance on manual design and extensive parameter tuning, a framework for the autonomous evolution of exoskeleton assistance policies through human feedback is proposed. Assistance policies are autonomously generated as executable control code by an intelligent agent and evaluated in experiments with human participants. Subjective user feedback, movement performance, and muscle activation measurements are incorporated into policy assessment. Based on these assessments, policy deficiencies are autonomously identified and the control code is revised by the agent for subsequent trials. A closed loop of policy generation, human feedback, evaluation, and autonomous refinement is thereby established. The framework is evaluated using GPT, DeepSeek, GLM, and Kimi, and initial assistance performance and refinement outcomes are compared across models. Despite differences in initial performance, effective assistance is achieved with all four models after a single autonomous refinement iteration under the tested conditions. Across three tasks, biceps and triceps muscle activation levels are reduced by 29.4% and 35.2%, respectively, compared with those measured without an exoskeleton. However, limited adaptability to unexpected situations is observed, indicating that further improvements in robustness and safety are required.

0.30

A Flow-Theoretic Multimodal Control Framework Fusing Mental and Physical Engagement for Upper-Limb Rehabilitation

cs.RO ·2026-10-15 ·Jun Leng, Pengcheng Li, Hanze Wang, Shuxiang Guo, Junlin Jiang
similarity 0.66
Abstract · 10 pages

While Assist-as-Needed (AAN) control aims to maximize user participation in robot-assisted training, existing methods relying solely on physical metrics cannot distinguish muscular inability from mental disengagement, leading to suboptimal interventions. To address this ambiguity, a Flow-theoretic multimodal AAN framework is proposed, fusing EEG-based mental engagement and sEMG-based physical engagement into an adaptive impedance control strategy. A four-quadrant fuzzy decision engine translates these dual physiological metrics into continuous control policies. This enables the upper-limb exoskeleton to inject feedforward assistance during intent-execution mismatch (e.g., motor output attenuation despite mental focus) and escalate guiding stiffness to penalize mental distraction. The framework was validated with healthy participants against a state-of-practice sEMG-only AAN baseline. Kinematically and mechanically, the proposed framework reduced robotic energy expenditure by 71.9\% while maintaining precise trajectory tracking, confirming it elicited greater voluntary human effort. Physiologically, the system increased the time spent in the neuroplasticity zone (Flow State Ratio) from 4.6% to 42.8%. These results validate that decoupling and jointly regulating mental and physical states enhances the selectivity of robotic assistance, mitigating user passivity and sustaining the engagement crucial for motor learning.

0.27

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.62
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24

Elbow Angle Guidance System Based on Surface Haptic Sensations Elicited by Lightweight Wearable Fabric Actuator

cs.HC cs.RO ·2026-08-11 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
published similarity 0.62
Abstract · This is the accepted version of the paper published in Proc. 2024 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), …

The demand for wearable haptic devices has rapidly increased for various applications. However, many haptic devices interfere with the wearer's activities and movements. In addition, several haptic devices fail to elicit intuitive haptic sensations by adjusting to the natural posture of the wearer. To address these issues, we propose an elbow angle guidance system using a lightweight wearable fabric actuator. The proposed actuator is made of fabric and has two McKibben-type artificial muscles attached to it, rendering it extremely lightweight and facilitating the delivery of surface haptic sensations to intuitively induce elbow extension and flexion. The surface haptic sensation elicited by the fabric actuator is adjusted to natural body movements without interfering with the wearer's movements. Moreover, the proposed system measures and guides the elbow angle by changing the intensity of the surface haptic sensation delivered to users in real time. The accuracy of the proposed system is demonstrated through experiments involving human participants.

0.65

Whole-Body Motion Guided Reference Generation for Uncertainty-Aware Compliant Assistance

cs.RO ·2026-10-22 ·Muyuan Ma, Long Cheng, Lijun Han, Haotian Zhai, Xinpan Meng +3 more
similarity 0.61
Abstract · Withdrawal requested because not all co-authors had consented to the submission of this manuscript to arXiv

Exoskeletons have shown great potential for augmenting human physical capabilities, yet generating reliable assistance remains challenging because human motion patterns and interaction requirements vary substantially in practice. To address this problem, a dual-loop assistance strategy is proposed to couple multimodal exoskeleton trajectory generation with variable admittance control, where trajectory variance links the outer-loop generator and the inner-loop controller. The generator synthesizes future exoskeleton trajectories through denoising, primarily using whole-body human motion and exoskeleton proprioception, with task descriptions as auxiliary semantic cues. To reduce cross-modal representation mismatch, a three-stage training pipeline is introduced to progressively optimize the human motion encoder, the exoskeleton proprioception encoder, and the trajectory generator. In the inner loop, multiple future trajectories are sampled from the generator to estimate the trajectory mean and variance. The mean is used as the control reference, while the variance provides an uncertainty measure for prediction reliability. This measure is further incorporated into a stiffness regulation law, enabling compliant assistance with input-to-state stability under bounded lumped interaction input. Experimental results demonstrate that the proposed method significantly reduces muscle activation levels compared with standard baselines, while also decreasing users' metabolic energy expenditure relative to the unassisted condition.

0.21

A generalist policy for muscle-driven control across individual musculoskeletal models

cs.RO ·2026-10-27 ·Bozhao Wang, Yinglei Zhu, Zhengqing Li, Zhiyuan Zhang, Weiming Kang +5 more
similarity 0.61
Abstract · 17 pages, 7 figures. Project website: https://woodater-thu.github.io/MyoAcross/ Bozhao Wang and Yinglei Zhu contributed equally to this work

Differences in musculoskeletal morphology challenge policy reuse across individual models. Here we present MyoAcross, a framework that combines individual musculoskeletal model construction, morphology-conditioned policy learning and virtual model augmentation to enable muscle-driven reference-motion tracking without individual fine-tuning. Across 31 held-out individual models, MyoAcross achieves 99.24% completion and reduces tracking error by 22.60% relative to an unconditioned multilayer perceptron. Policy reuse extends to models of 22 held-out individuals constructed from single-image shape estimates, measured height and body mass, and, with asymmetry augmentation, to models with unilateral lower-limb shortening. Comparisons with measurements from 120 additional individuals show agreement in vertical ground reaction force waveforms and channel-dependent agreement between simulated muscle activations and electromyography. These results establish a common control framework for comparative simulations of movement across individual musculoskeletal models.

0.38

Transformer-Based Trajectory Prescription for sEMG-Optimizing Robot-Mediated Rehabilitation

cs.RO cs.HCcs.LG ·2026-11-05 ·Gabriel Parra, Kimia Khoshnami, Daniel S. Brown, Laura A. Hallock
publishedcode/data similarity 0.60
Abstract · Accepted for presentation and publication in the 2026 Conference on Robot Learning (CoRL). PMLR, 2026

Robot-mediated rehabilitation has the potential to deliver high-intensity, individualized therapy, but existing systems (which have not consistently improved outcomes) typically prescribe kinematic trajectories rather than explicitly targeting the neuromotor activations thought to support recovery. To address this gap, and ultimately enable activation-optimizing rehabilitation robot behavior, we present a personalizable transformer-based model mapping individuals' muscle activations (as measured via surface electromyography) to prescribed contact force trajectories when interacting with an end-effector rehabilitation robot. The model uses a transformer encoder-decoder leveraging rotary positional embeddings (RoPE) to generate a latent representation of trajectory-relevant and user-specific neuromotor factors, and augments trajectory prediction with flow matching to produce a distribution over plausible prescriptions biased toward the training distribution. Using data from 16 healthy participants completing 15 isometric trajectory tracking tasks, we evaluate generalization across held-out tasks and users, as well as the feasibility of user-specific fine-tuning within a therapy-session timescale. The model achieves mean trajectory prediction errors of <8% on held out tasks and users, with effectively instantaneous deterministic inference and sub-second sampling of trajectory distributions. An initial test using the model during live rehabilitation tasks demonstrates that, on average, participants reach the target neuromotor activations with just 15% error accumulated throughout the task. These results provide a proof of concept for data-driven, activation-targeted trajectory prescription in robot-mediated rehabilitation and establish a foundation for future validation in clinical populations. Data and code have been open-sourced as part of the OpenRobotRehab project on SimTK.

0.34