CS Paper Radar

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij

cs.RO ·submitted 2026-11-17 13:34 UTC · v1

Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

Closest papers

Nearest neighbours by meaning across the whole index.

A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft Exosuits

cs.RO cs.HC ·2026-08-18 ·Anoush Sepehri, Zachary Huang, Raymond de Callafon, Michael T. Tolley, Tania K. Morimoto
similarity 0.66
Abstract

Pneumatic artificial muscles have provided new opportunities to develop upper-extremity soft exosuits for reha- bilitation, augmentation, and assisted daily living. However, the complex dynamics and limited bandwidth of these actuators has made providing responsive assistance based on user intention a longstanding challenge. In this work, we present an inverse-plant control strategy for pneumatically actuated soft exosuits that only relies on kinematic sensing for task-agnostic and dynamic assistance during daily living. We model the human-robot system using a Hammerstein dynamic model, consisting of a Preisach hysteresis model and a linear time-invariant filter, to capture the static and dynamic behavior of the system. We personalize our model to each user using 140 s of data and approximate an inverse to integrate into our control loop. When evaluated on a test rig that emulated a soft assistive exosuit for the wrist, our controller reduced the interaction torque by up to 73% and the activation of key flexor and extensor muscles by up to 47% relative to the condition with no assistance for speeds ranging from 8°/s to 120°/s. Overall, this work presents a control strategy that can provide task-agnostic, dynamic assistance with pneumatically actuated soft exosuits without the need for physiological or force sensors to interpret user intention.

0.19

A Reconfigurable Bidirectional Cable-Driven Hip Exoskeleton with Swappable Bench/Backpack Dual-configuration Actuation

cs.RO eess.SY ·2026-09-22 ·YuanLong Ji, Shuhan Xiang, Qihan Ye, Xingbang Yang
similarity 0.63
Abstract

Hip exoskeletons provide an important hardware basis for lower-limb rehabilitation and locomotor assistance. Laboratory rehabilitation assessment and system development require substantial actuation and computing resources, whereas mobile assistance requires untethered portability. Integrating both capabilities within one reusable platform remains a central design challenge. This paper presents a reconfigurable bidirectional cable-driven hip exoskeleton platform that rapidly switches between bench-mounted and backpack-mounted actuation while sharing one cable-free wearable hip interface. The platform modularly adapts the actuation configuration, end-effector sensing path, and low-level control interface. Each cable-driven end-effector weighs 0.405 kg, excluding the cable and actuation unit, and integrates an encoder and a torque sensor; experiments validated bench-mounted admittance-based motion tracking capability and backpack-mounted open-loop torque tracking. Human-worn experiments with three healthy participants used myoMOTION to evaluate the platform's wearable-side hip-motion sensing capability, verified bench-to-backpack and backpack-to-bench motion-ready switching across 30 trials in $30.1\pm16.3$ s, and formed a small-scale multimodal wearable-exoskeleton gait dataset for sensing validation and data-driven algorithm development, comprising 8 min bench-mounted treadmill records and 11 min backpack-mounted outdoor walking records. These results show that, by unifying the wearable structure, actuation interface, and sensing path, the proposed platform enables validation of the same hip exoskeleton in both bench-mounted and backpack-mounted configurations, providing reusable hardware for iterative development and applications across scenarios.

0.18

Myoelectric Control for Upper-Limb Exoskeletons: A Decoder-Shaper-Controller Framework, Design Guidelines, and Future Directions

cs.RO ·2026-11-02 ·Davide Costanzi, Eldison Dimo, Emanuele Feola, Mario Sedilesu, Francesco Pascucci +1 more
similarity 0.62
Abstract · 19 pages, 3 figures. Review paper

Myoelectric Control Systems (MCSs) enable voluntary control of wearable robots through muscle activity. However, intention decoding, assistance shaping, and low-level actuator control are often not explicitly distinguished, making their contributions difficult to evaluate and compare. This review introduces a functional decoder-shaper-controller framework for continuous myoelectric control of upper-limb exoskeletons. The decoder estimates an intention-related variable from surface electromyography (sEMG), the shaper maps it to a control reference according to an assistance policy, and the controller realizes that reference through actuator control. This decomposition separates intention estimation from assistance-policy design and enables comparison of heterogeneous architectures. Representative approaches are critically examined in terms of module design, calibration, and evaluation. The analysis highlights that the shaper, despite determining the magnitude and shape of assistance, lacks established design and tuning methodologies and is often embedded within the decoder or controller. Key open issues include inconsistent reporting of assistance levels, limited use of interaction-aware stability and passivity tools, and insufficient validation across degrees of freedom, users, and tasks. Building on these findings, this review provides design guidelines for systematic module-wise tuning and identifies future research priorities to bridge the gap between accurate intention decoding and safe, effective, and generalizable assistance under real-world operating conditions.

0.16

A Human-in-the-Loop Comparison of Proportional Control and Adaptive Gravity Compensation in Elbow EMG-Driven Exoskeletons

cs.RO ·2026-10-19 ·Francesco Pascucci, Eldison Dimo, Davide Costanzi, Mario Sedilesu, Andrea Calanca
similarity 0.58
Abstract · 8 pages, 10 figures, 4 tables

Electromyography (EMG)-driven control enables wearable robots to assist users based on their neuromuscular activity. Upper-limb exoskeletons typically rely on proportional myoelectric control (PMC), which amplifies user effort but may compromise stability at high assistance levels. EMG-driven adaptive gravity compensation (AGC) offers a promising alternative, counterbalancing gravitational torques while continuously adapting to neuromuscular activity. However, these approaches have not been systematically compared in a human-in-the-loop setting. This study evaluates five control algorithms: two PMC strategies at different assistance levels, a purely integral AGC (AGC-PI), a kinematics- and acceleration-aware model-based (MB) AGC (AGC-AW), and a novel MB AGC approach based on Recursive Least Squares (AGC-RLS) for online payload estimation. Fourteen healthy participants performed target-reaching tasks using an active elbow exoskeleton under 0 kg and 2 kg loading conditions. Performance metrics included muscular activity, movement accuracy, task efficiency, and subjective workload. PMC exhibited a trade-off between physical effort and task performance: low assistance levels required greater physical effort under load, whereas high gains impaired task execution. AGC-PI reduced agonist activity but induced antagonist activation. In contrast, both model-based AGC approaches effectively compensated for external payloads, reducing physical and cognitive demands while improving movement accuracy and completion time.

0.20

Elbow Angle Guidance System Based on Surface Haptic Sensations Elicited by Lightweight Wearable Fabric Actuator

cs.HC cs.RO ·2026-08-11 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
published similarity 0.58
Abstract · This is the accepted version of the paper published in Proc. 2024 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), …

The demand for wearable haptic devices has rapidly increased for various applications. However, many haptic devices interfere with the wearer's activities and movements. In addition, several haptic devices fail to elicit intuitive haptic sensations by adjusting to the natural posture of the wearer. To address these issues, we propose an elbow angle guidance system using a lightweight wearable fabric actuator. The proposed actuator is made of fabric and has two McKibben-type artificial muscles attached to it, rendering it extremely lightweight and facilitating the delivery of surface haptic sensations to intuitively induce elbow extension and flexion. The surface haptic sensation elicited by the fabric actuator is adjusted to natural body movements without interfering with the wearer's movements. Moreover, the proposed system measures and guides the elbow angle by changing the intensity of the surface haptic sensation delivered to users in real time. The accuracy of the proposed system is demonstrated through experiments involving human participants.

0.65

Recursive Self-Improvement of Exoskeleton Assistance Policies through Human-in-the-Loop Feedback

cs.RO ·2026-11-01 ·Muyuan Ma, Shuo Jiang, Lijun Han, Xinpan Meng, Zhenghua Ma +3 more
hot direction similarity 0.58
Abstract

To reduce reliance on manual design and extensive parameter tuning, a framework for the autonomous evolution of exoskeleton assistance policies through human feedback is proposed. Assistance policies are autonomously generated as executable control code by an intelligent agent and evaluated in experiments with human participants. Subjective user feedback, movement performance, and muscle activation measurements are incorporated into policy assessment. Based on these assessments, policy deficiencies are autonomously identified and the control code is revised by the agent for subsequent trials. A closed loop of policy generation, human feedback, evaluation, and autonomous refinement is thereby established. The framework is evaluated using GPT, DeepSeek, GLM, and Kimi, and initial assistance performance and refinement outcomes are compared across models. Despite differences in initial performance, effective assistance is achieved with all four models after a single autonomous refinement iteration under the tested conditions. Across three tasks, biceps and triceps muscle activation levels are reduced by 29.4% and 35.2%, respectively, compared with those measured without an exoskeleton. However, limited adaptability to unexpected situations is observed, indicating that further improvements in robustness and safety are required.

0.30

A dynamic backrest may help accommodate trunk movement, and multi-device work elicits more of it: An exploratory comparison of high-end office chairs under single- and multi-device tasks

cs.HC ·2026-11-02 ·Yejin Kang, Dusan Baek, Dongwoo Park, Kitae Hwang, Woojin Park
similarity 0.58
Abstract · 22 pages, 4 figures

Dynamic-sitting office chairs are usually compared with static sitting rather than with each other, and the contribution of backrest deformability (lateral backrest movement) is unknown. Office work also increasingly spans multiple devices. Twenty healthy adults (10 men, 10 women) completed a 15-minute single-device and a 15-minute multi-device proofreading task on each of three chairs: two commercial dynamic-sitting chairs (T90, Aeron) and a T90 whose backrest lateral movement was mechanically fixed (T90-fixed). We recorded subjective ratings, head and trunk posture (inertial measurement units), upper trapezius and lateral gastrocnemius activity (electromyography), and task performance. Chair effects were largely null: T90 and Aeron did not differ in ratings or performance, posture and muscle activity showed only isolated, direction-inconsistent differences, and preferences were polarized. The standard T90 showed greater trunk movement (mean absolute angular velocity in yaw) than T90-fixed during the multi-device task (p = 0.042), which may indicate that its movable backrest helps accommodate trunk movement under demanding work; no other whole-sample posture, muscle, rating or performance measure differed between these two configurations, and replication is needed. Task effects were large and consistent: the multi-device task elicited greater and faster head, trunk and shoulder movement and higher upper trapezius activity than the single-device task, with lower reading throughput. Multi-device work thus imposes substantially greater movement demands than single-device work, which supports designing chairs that accommodate movement in modern work environments.

0.42

MESSPa: A Multi-modal Embodiment Stimulation Shoulder Pad for Preserving the Sense of Agency in a Detachable Robotic Arm

cs.RO cs.HC ·2026-10-31 ·Vitvasin Vimolmongkolporn, Guillaume Gourmelen, Yukiko Iwasaki, Hiroyasu Iwata
published similarity 0.57
Abstract · 8 pages, 8 figures. Accepted to the 2026 IEEE-RAS International Conference on Humanoid Robots (Humanoids 2026)

Wearable robots such as supernumerary robotic limbs (SRLs) can augment human capability, but their effectiveness depends strongly on the operator's sense of embodiment, comprising the sense of agency (SoA) and the sense of ownership (SoO). When an SRL is detached from the body so that the operator can act in two places at once, both the sense of agency and task performance tend to degrade. This paper presents the Multi-modal Embodiment Stimulation Shoulder Pad (MESSPa), a wearable interface that combines one-to-one motion transfer with spatially distributed pneumatic (balloon) haptic feedback on the shoulder, with the goal of preserving the sense of agency across attached and detached states. We describe the system design, the control mapping, and a controlled experiment using a $2\times2$ mixed design that crosses the control interface between groups (MESSPa, $N=13$, vs. keyboard control, $N=12$ from our previous study) and attachment (on-shoulder/detached) within participants, under single- and dual-task loads. Compared with keyboard control in the detached condition, MESSPa significantly reduced task completion time and significantly improved the sense of agency in the detached state, while narrowing the performance gap between the attached and detached conditions. The sense of ownership did not change significantly. These results indicate that combining motion transfer with positional haptic feedback is an effective way to recover agency when a robotic limb is operated remotely.

0.32