CS Paper Radar

A Reconfigurable Bidirectional Cable-Driven Hip Exoskeleton with Swappable Bench/Backpack Dual-configuration Actuation

YuanLong Ji, Shuhan Xiang, Qihan Ye, Xingbang Yang

cs.RO eess.SY ·submitted 2026-09-22 03:49 UTC · v1

Abstract

Hip exoskeletons provide an important hardware basis for lower-limb rehabilitation and locomotor assistance. Laboratory rehabilitation assessment and system development require substantial actuation and computing resources, whereas mobile assistance requires untethered portability. Integrating both capabilities within one reusable platform remains a central design challenge. This paper presents a reconfigurable bidirectional cable-driven hip exoskeleton platform that rapidly switches between bench-mounted and backpack-mounted actuation while sharing one cable-free wearable hip interface. The platform modularly adapts the actuation configuration, end-effector sensing path, and low-level control interface. Each cable-driven end-effector weighs 0.405 kg, excluding the cable and actuation unit, and integrates an encoder and a torque sensor; experiments validated bench-mounted admittance-based motion tracking capability and backpack-mounted open-loop torque tracking. Human-worn experiments with three healthy participants used myoMOTION to evaluate the platform's wearable-side hip-motion sensing capability, verified bench-to-backpack and backpack-to-bench motion-ready switching across 30 trials in $30.1\pm16.3$ s, and formed a small-scale multimodal wearable-exoskeleton gait dataset for sensing validation and data-driven algorithm development, comprising 8 min bench-mounted treadmill records and 11 min backpack-mounted outdoor walking records. These results show that, by unifying the wearable structure, actuation interface, and sensing path, the proposed platform enables validation of the same hip exoskeleton in both bench-mounted and backpack-mounted configurations, providing reusable hardware for iterative development and applications across scenarios.

Closest papers

Nearest neighbours by meaning across the whole index.

Design and Control of a Cable-Driven Switchable Actuator with Torque/Tension Dual Modes for Exoskeletons

cs.RO eess.SY ·2026-09-20 ·YuanLong Ji, Xu Liu, Xinyuan Cai, Qihan Ye, Xiangyu Xie +6 more
top venue similarity 0.66
Abstract

Existing wearable exoskeleton architectures are typically constrained by a single mechanical output modality, providing either joint torque around an anatomical joint or linear traction along a limb-training-oriented direction, which limits adaptability to diverse training scenarios. This letter presents a cable-driven switchable actuator (CDSA) that can rapidly switch between torque and tension modes while centralizing all sensing and actuation components at the proximal drive unit. A Coupled Movable Pulley Mechanism (CMPM) provides tension amplification at the distal end-effector, while a bidirectional Cable-Driven Ratchet Mechanism (CDRM) enables mode switching and preload regulation. To eliminate the need for distal instrumentation, multi-source proximal sensors are integrated with a data-driven fusion model to estimate distal output forces. An adaptive dual-mode force control strategy based on iterative learning control (ILC) is further developed. Platform experiments demonstrate transmission efficiencies of $(92.4 \pm 2.0)\%$ and $(96.5 \pm 3.3)\%$ in the torque and tension modes, respectively, along with a tension amplification ratio of $2.77 \pm 0.10$ under tension mode. Tracking tests on simulated knee-joint gait trajectories and short-stroke tension profiles yield stable control, with RMSEs of $(4.52 \pm 0.51)\%$ and $(3.15 \pm 0.19)\%$ of the uncontrolled peak value, respectively. Finally, seated human-coupled experiments validate the system's controllable force generation in both joint-torque and linear-traction application modes.

0.40

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.63
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.63
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Effects of Assistance Delay on Joint Mechanics and Energetics in Biological Torque Control of a Hip Exoskeleton

cs.RO ·2026-09-21 ·Jimin An, Ryan Lee, Jingshu Peng, Eni Halilaj, Inseung Kang
similarity 0.60
Abstract · 8 Pages, 4 figures

Biological torque control directly maps an estimated human joint moment to exoskeleton assistance, providing a task-agnostic strategy for supporting diverse locomotor activities. However, it remains unclear whether a fixed state-to-torque mapping provides effective assistance across biomechanically distinct tasks. We examined how assistance delay affected hip exoskeleton performance during level-ground (LG), ramp-ascent (RA), and ramp-descent (RD) walking. Eight participants completed a zero-torque baseline condition and five active assistance conditions with delays ranging from 40 to 320 ms. Across tasks and active delays, assistance reduced net metabolic rate by 5.24%, positive biological hip joint work by 5.86%, and total lower-limb positive joint work by 1.68% (all p < 0.05). Assistance delay affected both joint-work outcomes (both p < 0.001) but not net metabolic rate. Mechanical unloading generally decreased with increasing delay, whereas metabolic benefits remained comparatively stable. Relative to the zero-torque condition, net metabolic rate decreased by 9.75% during LG and 7.20% during RA but increased by 1.23% during RD. We did not detect task-dependent differences in the delay response. Our findings indicate that biological torque mappings should be evaluated based on the target outcome and mechanical role of the assisted joint, and that predominantly positive-power assistance may not generalize to negative-work-dominant locomotion without modification.

0.32

A Human-in-the-Loop Comparison of Proportional Control and Adaptive Gravity Compensation in Elbow EMG-Driven Exoskeletons

cs.RO ·2026-10-19 ·Francesco Pascucci, Eldison Dimo, Davide Costanzi, Mario Sedilesu, Andrea Calanca
similarity 0.60
Abstract · 8 pages, 10 figures, 4 tables

Electromyography (EMG)-driven control enables wearable robots to assist users based on their neuromuscular activity. Upper-limb exoskeletons typically rely on proportional myoelectric control (PMC), which amplifies user effort but may compromise stability at high assistance levels. EMG-driven adaptive gravity compensation (AGC) offers a promising alternative, counterbalancing gravitational torques while continuously adapting to neuromuscular activity. However, these approaches have not been systematically compared in a human-in-the-loop setting. This study evaluates five control algorithms: two PMC strategies at different assistance levels, a purely integral AGC (AGC-PI), a kinematics- and acceleration-aware model-based (MB) AGC (AGC-AW), and a novel MB AGC approach based on Recursive Least Squares (AGC-RLS) for online payload estimation. Fourteen healthy participants performed target-reaching tasks using an active elbow exoskeleton under 0 kg and 2 kg loading conditions. Performance metrics included muscular activity, movement accuracy, task efficiency, and subjective workload. PMC exhibited a trade-off between physical effort and task performance: low assistance levels required greater physical effort under load, whereas high gains impaired task execution. AGC-PI reduced agonist activity but induced antagonist activation. In contrast, both model-based AGC approaches effectively compensated for external payloads, reducing physical and cognitive demands while improving movement accuracy and completion time.

0.20

Myoelectric Control for Upper-Limb Exoskeletons: A Decoder-Shaper-Controller Framework, Design Guidelines, and Future Directions

cs.RO ·2026-11-02 ·Davide Costanzi, Eldison Dimo, Emanuele Feola, Mario Sedilesu, Francesco Pascucci +1 more
similarity 0.59
Abstract · 19 pages, 3 figures. Review paper

Myoelectric Control Systems (MCSs) enable voluntary control of wearable robots through muscle activity. However, intention decoding, assistance shaping, and low-level actuator control are often not explicitly distinguished, making their contributions difficult to evaluate and compare. This review introduces a functional decoder-shaper-controller framework for continuous myoelectric control of upper-limb exoskeletons. The decoder estimates an intention-related variable from surface electromyography (sEMG), the shaper maps it to a control reference according to an assistance policy, and the controller realizes that reference through actuator control. This decomposition separates intention estimation from assistance-policy design and enables comparison of heterogeneous architectures. Representative approaches are critically examined in terms of module design, calibration, and evaluation. The analysis highlights that the shaper, despite determining the magnitude and shape of assistance, lacks established design and tuning methodologies and is often embedded within the decoder or controller. Key open issues include inconsistent reporting of assistance levels, limited use of interaction-aware stability and passivity tools, and insufficient validation across degrees of freedom, users, and tasks. Building on these findings, this review provides design guidelines for systematic module-wise tuning and identifies future research priorities to bridge the gap between accurate intention decoding and safe, effective, and generalizable assistance under real-world operating conditions.

0.16

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

cs.RO ·2026-10-02 ·Neethan Ratnakumar, Mariya Tohfafarosh, Xianlian Zhou
similarity 0.58
Abstract

Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.

0.14

Design and Analysis of a Nonlinear Parallel Mechanism Coupling for Dynamic Humanoid Legs

cs.RO ·2026-10-12 ·Rohit Kumar, Heiner Peters, Felix Wiebe, Franek Stark, Janne Janzen +3 more
similarity 0.58
Abstract

Humanoids increasingly demand lightweight leg mechanisms for agile, dynamic, and energy-efficient locomotion. Reducing distal inertia through proximal actuation has thus become a common design goal. Yet, compact transmissions that preserve torque capability and efficient force transmission remain hard to achieve. This paper presents a novel series-parallel leg design combining a knee parallel mechanism, an ankle parallel mechanism, and a nonlinear knee-ankle coupling where all actuators placed closer to the hip. As the knee flexes, the coupling passively assists ankle dorsiflexion for foot clearance and, as it extends it assists plantarflexion for push-off, redistributing ankle load through the knee transmission. We derive the coupling's nonlinear transmission models and validate them in simulation and on hardware. The design shows that the shared transmission lets both joints draw on each other's actuator capacity by easing the knee's peak torque demand under load and the ankle's peak speed demand during fast motion. With the leg's proximal actuator placement, the leg achieves an effective reflected mass of 0.37 kg at the foot for a 6 kg leg, demonstrating very low distal leg inertia for dynamic humanoid robots.

0.12