Design and Control of a Cable-Driven Switchable Actuator with Torque/Tension Dual Modes for Exoskeletons

YuanLong Ji, Xu Liu, Xinyuan Cai, Qihan Ye, Xiangyu Xie, Ruizhe Jiang, Shuhan Xiang, Wenjing Liu, Qijun Wang, Yang Chen, Xingbang Yang

cs.RO eess.SY ·submitted 2026-09-20 09:20 UTC · v1
top venue

Abstract

Existing wearable exoskeleton architectures are typically constrained by a single mechanical output modality, providing either joint torque around an anatomical joint or linear traction along a limb-training-oriented direction, which limits adaptability to diverse training scenarios. This letter presents a cable-driven switchable actuator (CDSA) that can rapidly switch between torque and tension modes while centralizing all sensing and actuation components at the proximal drive unit. A Coupled Movable Pulley Mechanism (CMPM) provides tension amplification at the distal end-effector, while a bidirectional Cable-Driven Ratchet Mechanism (CDRM) enables mode switching and preload regulation. To eliminate the need for distal instrumentation, multi-source proximal sensors are integrated with a data-driven fusion model to estimate distal output forces. An adaptive dual-mode force control strategy based on iterative learning control (ILC) is further developed. Platform experiments demonstrate transmission efficiencies of $(92.4 \pm 2.0)\%$ and $(96.5 \pm 3.3)\%$ in the torque and tension modes, respectively, along with a tension amplification ratio of $2.77 \pm 0.10$ under tension mode. Tracking tests on simulated knee-joint gait trajectories and short-stroke tension profiles yield stable control, with RMSEs of $(4.52 \pm 0.51)\%$ and $(3.15 \pm 0.19)\%$ of the uncontrolled peak value, respectively. Finally, seated human-coupled experiments validate the system's controllable force generation in both joint-torque and linear-traction application modes.

Closest papers

Nearest neighbours by meaning across the whole index.

A Reconfigurable Bidirectional Cable-Driven Hip Exoskeleton with Swappable Bench/Backpack Dual-configuration Actuation

cs.RO eess.SY ·2026-09-22 ·YuanLong Ji, Shuhan Xiang, Qihan Ye, Xingbang Yang
similarity 0.66
Abstract

Hip exoskeletons provide an important hardware basis for lower-limb rehabilitation and locomotor assistance. Laboratory rehabilitation assessment and system development require substantial actuation and computing resources, whereas mobile assistance requires untethered portability. Integrating both capabilities within one reusable platform remains a central design challenge. This paper presents a reconfigurable bidirectional cable-driven hip exoskeleton platform that rapidly switches between bench-mounted and backpack-mounted actuation while sharing one cable-free wearable hip interface. The platform modularly adapts the actuation configuration, end-effector sensing path, and low-level control interface. Each cable-driven end-effector weighs 0.405 kg, excluding the cable and actuation unit, and integrates an encoder and a torque sensor; experiments validated bench-mounted admittance-based motion tracking capability and backpack-mounted open-loop torque tracking. Human-worn experiments with three healthy participants used myoMOTION to evaluate the platform's wearable-side hip-motion sensing capability, verified bench-to-backpack and backpack-to-bench motion-ready switching across 30 trials in $30.1\pm16.3$ s, and formed a small-scale multimodal wearable-exoskeleton gait dataset for sensing validation and data-driven algorithm development, comprising 8 min bench-mounted treadmill records and 11 min backpack-mounted outdoor walking records. These results show that, by unifying the wearable structure, actuation interface, and sensing path, the proposed platform enables validation of the same hip exoskeleton in both bench-mounted and backpack-mounted configurations, providing reusable hardware for iterative development and applications across scenarios.

0.18

ExoLaN: Physics-Consistent Context-Aware Dynamics Learning for Exoskeletons

cs.RO eess.SY ·2026-09-25 ·Lucas Schulze, Maximilian Schwarz, Jona Hoppe, Jan Peters, Oleg Arenz
similarity 0.61
Abstract

Task-agnostic assistive exoskeleton control based on human intention offers greater flexibility than conventional approaches that rely on predefined tasks or motion patterns. Human joint torque estimation enables task-agnostic assistance by characterizing user actions. Physics-consistent methods such as Deep Lagrangian Networks (DeLaN) have been applied to estimate the human torques in multi-user settings, but existing approaches cannot adapt to a specific user without retraining, and do not account for intermittent contacts during locomotion. We propose ExoLaN, a Context-Aware DeLaN for human-exoskeleton interaction that learns the full coupled system dynamics while adapting to changes in interaction context. ExoLaN combines temporal context with partial contact-force measurements from force-sensitive insoles to infer latent dynamics embeddings and estimate generalized contact torques. On seven unseen users performing 21 unseen tasks, ExoLaN reduces torque estimation MSE by 7% compared to a black-box baseline. Beyond inverse dynamics, ExoLaN serves as a unified model that also enables accurate forward prediction: training with a multi-step prediction loss reduces acceleration MSE by 59% and long-horizon position and velocity errors by 60% and 93%, respectively, compared with a single-step loss. Moreover, the learned latent context captures task information without explicit task labels, making it a promising signal for task-aware assistive control.

0.19

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.61
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Force-Aware Reinforcement Learning with Hybrid Sensorless Force Estimation for Wheeled-Legged Loco-Manipulation

cs.RO ·2026-09-12 ·Xuanqi Zeng, Jiaming Wang, Tianlin Zhang, Lingwei Zhang, Botian Xu +3 more
similarity 0.60
Abstract · 12 pages, 8 figures, 2 tables

Force-controlled loco-manipulation requires a whole-body policy to coordinate locomotion and arm motion while regulating end-effector interaction forces. This is challenging under floating-base dynamics and changing support contacts, particularly when end-effector force/torque sensing is unavailable for control. This paper presents a force-aware reinforcement learning approach with hybrid sensorless force estimation for wheeled-legged loco-manipulation. The proposed method provides a structured estimate of the end-effector force as an explicit policy observation, enabling force-guided contact behavior without using an end-effector force/torque sensor for control. The force estimate is obtained by combining generalized momentum observation, contact-constrained wrench projection, and temporal residual learning: the model-based components extract the physically structured part of the whole-body disturbance, while the residual network compensates the remaining motion-dependent bias. The estimated force is integrated into a mode-conditioned whole-body policy with an axis-wise force/position selector, allowing free-space motion, pure force regulation, and hybrid force/position control within one controller. Simulation results demonstrate improved sensorless force estimation and force-control performance. Hardware experiments further validate the proposed controller through quantitative valve-rotation and hybrid wiping evaluations, together with force-guided door opening and zero-force human-guided motion on a real wheeled-legged platform.

0.38

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

cs.RO ·2026-10-30 ·Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang
code/data similarity 0.60
Abstract · 8 pages, 5 figures, 2 tables

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

0.22

A Compact Robotic Finger with 2-DoF MCP Joint Embedding DoF-Selective Passive Continuously Variable Transmission for Wide Force-Speed Operating Range

cs.RO ·2026-09-01 ·JaeHyung Jang, Jee-Hwan Ryu
similarity 0.60
Abstract · 9 pages, 4 figures

This letter presents a compact two-degree-of-freedom (DoF) robotic finger with a flexion-selective passive continuously variable transmission (CVT) to achieve a wide force-speed operating range. Inspired by the functional differentiation of the human metacarpophalangeal (MCP) joint, the proposed mechanism realizes DoF-specific transmission differentiation by selectively assigning passive CVT to the flexion-extension DoF while preserving direct transmission for abduction-adduction. For a wide force-speed operating range, a force-responsive passive CVT is embedded in the flexion pathway, while direct transmission is preserved for the abduction-adduction pathway. To selectively realize transmission adaptation within a multi-DoF MCP mechanism, an output-side passive CVT employing a moving-pulley-inspired wire-routing structure is introduced. The resultant force generated by the wire tensions acting on the pulley that passively increases the flexion moment arm and transmission ratio according to the applied load without additional actuators, sensors, or control. Experimental results demonstrate a maximum output-force amplification of 4.19-fold and a mean amplification of 3.6-fold across the tested flexion angles ranging from 15 degrees to 75 degrees through moment-arm adaptation, thereby substantially expanding the achievable force-speed operating range. Furthermore, dexterous ball-rolling experiments verify that passive transmission adaptation can be achieved while preserving abduction-adduction functionality. These results demonstrate a scalable transmission design strategy for compact multi-DoF robotic hands.

0.23

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.59
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

Attribution-Gated Joint Estimation of Intention and Capability for Assist-as-Needed Upper-Limb Robots

cs.RO ·2026-10-15 ·Pengcheng Li, Shuxiang Guo, Hanze Wang, Jun Leng, Bin Wang +1 more
similarity 0.59
Abstract · 31 pages, 7 figures

Assist-as-needed (AAN) control must distinguish between changes in intended motion and changes in effective voluntary torque capability, even though both can produce similar kinematic and interaction responses. A dual-measurand multimodal MHE-MPC architecture is developed as the base framework, in which the intended trajectory and the task-dependent effective voluntary torque capability are estimated online as distinct quantities, and both estimates are used to adapt robotic assistance. Building on this architecture, the ambiguity between the two update channels is formulated as a continuous credit-assignment problem and resolved by an attribution gate. A trajectory-change indicator is obtained from persistent corrective interaction, whereas a capability-change indicator is derived from the residual between normalized muscle activation and dynamics-reconstructed voluntary torque. Nine healthy participants completed factorial target-height-load trials and a pre-post fatigue cup-transport task. Without target-height input, the gated method generated correctly ordered Low-Middle-High references under every load: target changes were preferentially assigned to trajectory adaptation, whereas added load shifted adaptation toward the capability channel. It achieved the lowest RMSE in all nine conditions (0.017 rad versus 0.041 rad for ungated dual estimation and 0.127 rad for fixed-reference error-based AAN). Post-fatigue capability estimates decreased and assistance increased at all heights, supporting functional feasibility.

0.20