CS Paper Radar

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang

cs.RO ·submitted 2026-10-30 16:29 UTC · v1
code/data

Abstract

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

Comment
8 pages, 5 figures, 2 tables

Closest papers

Nearest neighbours by meaning across the whole index.

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.74
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.48

Assistance Torque Estimation via Dynamics-Aware Optimization for Lower-Limb Exoskeleton in Complex Environments

cs.RO ·2026-09-14 ·Xiao-Yin Liu, Guotao Li, Weiqun Wang, Zeng-Guang Hou
similarity 0.69
Abstract · 8 pages, 11 figures, https://youtu.be/CGxDD0jKpak

Ground-truth human joint torque estimation relies on motion capture systems, which suffer from limited outdoor usability and significant deployment expenses. Furthermore, direct scaling of ground-truth joint torques to obtain motor torque commands is not necessarily the optimal strategy. To address the aforementioned limitations, inspired by the human motion generation process, this paper proposes a novel assistance torque estimation method based on the dynamic model. From an optimization perspective, the proposed method directly generates motor-assist torque and lowers the cost of data acquisition. Then, a data-driven assistance torque prediction network is trained to enable accurate real-time prediction under complex outdoor environments. Experimental results demonstrate that optimized (estimated) assistance torque exhibits better phase consistency with gait trajectories and better alignment with task characteristics. Relative to the Zero torque condition, the predicted torque can decrease metabolic rate by 11.8%-17.7%, heart rate by 8.9%-14.3%, and peak muscle activation levels by 28.2%-54.0%, respectively. This provides a new perspective for low-cost adaptive exoskeleton assistance.

0.21

Design and Validation of a Lightweight, Low-Profile Powered Knee Prosthesis with Quasi-Direct Drive Actuation

cs.RO ·2026-09-02 ·Ross J. Cortino, Ryan Posh, Emily G. Keller, Robert D. Gregg
similarity 0.64
Abstract · 11 pages, 8 figures, Under Review

Fully-powered knee prostheses, unlike traditional passive knees, can perform controlled positive work, reducing the need for compensatory behaviors by users during energy-intensive activities. While quasi-direct drive (QDD) actuators provide superior torque control, backdrivability, and acoustic noise properties compared to traditional highly-geared actuators, prior QDD prototypes have been too heavy and bulky for commercial translation. In this work, we present the design and validation of a new lightweight (2.6 kg) and low-profile (24.5 cm tip-to-tip build height) QDD knee prosthesis. By optimizing an 18 to 1 two-stage transmission alongside thermal and structural finite-element analyses, we significantly reduce device mass while enabling a peak torque of 145 Nm. Through benchtop tests, we validate the device's high output torque, low backdrive torque (1 Nm), and its precision position and torque control capabilities. We also demonstrate biomimetic kinematics and peak knee extension torques (within one standard deviation of able-bodied references) during both level-ground walking and sit-stand transitions performed by three participants with transfemoral amputation and varying K-levels. By meeting or improving upon the mass, build height, peak torque, and acoustic noise of a leading commercial powered knee, this work establishes the clinical viability of emerging QDD prostheses that promise improved dynamic performance for their users.

0.32

Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls

cs.RO cs.LGeess.SP ·2026-11-14 ·Jiaying Xu, Guangyuan Chen, Buyun Gao, Zhen Dong
similarity 0.63
Abstract · 8 pages, 5 figures, 3 tables. Submitted to IEEE Robotics and Automation Letters (RA-L)

Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise $R^2$ from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity ($G_\mathrm{T} = +0.053$) and half as much once own other-activity data exist ($G_\mathrm{W} = +0.028$); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.

0.23

Learning a Speed-adaptive Hip Exoskeleton Control Policy Via Sim-to-real Reinforcement Learning

cs.RO ·2026-09-23 ·Bin Li, Zhimin Hou, Jiacheng Hou, Zenian Liang, Tong Wu +2 more
similarity 0.63
Abstract

Providing personalized exoskeleton assistance across varying walking speeds remains challenging. Existing online optimization methods are sample-inefficient, requiring extensive human-in-the-loop (HIL) evaluations to optimize the entire assistive torque profile. Sim-to-real reinforcement learning (RL) offers a promising alternative but cannot directly account for individual user preferences. We propose a framework integrating sim-to-real RL with online preference learning for personalized exoskeleton assistance. Specifically, assistance timing is learned in simulation by training RL policies with human musculoskeletal models across varying walking speeds. The learned policies are then distilled and deployed on a physical hip exoskeleton using onboard sensory observations. Gaussian-process-based preference learning further personalizes the assistance magnitude through pairwise user comparisons. By decoupling assistance timing learning in simulation from magnitude optimization in real-world experiments, our framework substantially reduces the online optimization space. Human-subject experiments demonstrate efficient identification of personalized assistive torque profiles across varying walking speeds with fewer real-world evaluations.

0.14

Dataset-Free Compliant Humanoid Loco-Manipulation with Dynamic Online Posture

cs.RO ·2026-10-05 ·Seungho Yeom, Zhenyu Wu, Jaeyoung Huh, Diego Williams, Yuheng Zhi +2 more
similarity 0.63
Abstract

Most humanoid loco-manipulation controllers require human motion data to learn whole-body coordination and posture, leaving policies reliant on external sources to provide this data. We present OCLO (Online-posture Compliant LOco-manipulation), a humanoid loco-manipulation system trained without human motion data and commanded only through two end-effector targets. Because these targets do not uniquely determine whole-body posture, OCLO generates pelvis height and torso orientation online using an analytic reachability prior, further refined through policy-in-the-loop sampling with a task-agnostic cost. OCLO also learns whole-body compliance by displacing end-effector references according to measured forces through a spring-damper model, encouraging the legs, waist, and pelvis to yield to external loads. In simulation, using the reachability prior leads to a 77.8% success rate in acquiring the commanded reference, a vast improvement over the 37.8% success rate accomplished without the prior. Further, refinement reduces end-effector orientation error across all evaluated tasks. The same posture module improves a pretrained SONIC controller on four of five tasks. Without compliance training, policies tend to lose balance under disturbances rather than sacrifice tracking. On a Unitree G1, OCLO maintains balance under end-effector disturbances that cause its ablations to fail and performs seven loco-manipulation tasks, including crouched walking and picking up a box from a low surface. Project website: https://oclo-humanoid.github.io/

0.27

General Performance Guarantee for Human Torque Estimation-Based Task-Agnostic Assistive Exoskeleton Control

cs.RO cs.LGeess.SY ·2026-09-30 ·Duy Hoang, Bastien Berret, Olivier Bruneau, Laurent Fribourg
theory similarity 0.63
Abstract · 10 pages, 8 figures

Accurate human torque estimation is crucial for enabling task-agnostic control in robotic exoskeleton systems. However, estimation errors may cause mismatches between the robot assistance and the human intention, degrading controllability and task performance. In this paper, we address this issue by formally defining matched assistance as scenarios in which the robot positively contributes to human movement. Based on this definition, we develop a theoretical framework to design the robot's desired interaction torque that guarantees a lower bound on the matched assistance probability. Importantly, the proposed guarantee holds over the entire torque distribution, including unseen data beyond the training tasks. This provides our method with strong reliability and generalization, both of which are critical for effective exoskeleton control. The proposed strategy is implemented on the ABLE upper-limb exoskeleton and evaluated in a multi-task setup. Experimental results validate the theoretical guarantees and demonstrate that the proposed strategy achieves effective general performance across several tasks, guaranteeing movement smoothness while reducing human physical effort.

0.19

ExoLaN: Physics-Consistent Context-Aware Dynamics Learning for Exoskeletons

cs.RO eess.SY ·2026-09-25 ·Lucas Schulze, Maximilian Schwarz, Jona Hoppe, Jan Peters, Oleg Arenz
similarity 0.62
Abstract

Task-agnostic assistive exoskeleton control based on human intention offers greater flexibility than conventional approaches that rely on predefined tasks or motion patterns. Human joint torque estimation enables task-agnostic assistance by characterizing user actions. Physics-consistent methods such as Deep Lagrangian Networks (DeLaN) have been applied to estimate the human torques in multi-user settings, but existing approaches cannot adapt to a specific user without retraining, and do not account for intermittent contacts during locomotion. We propose ExoLaN, a Context-Aware DeLaN for human-exoskeleton interaction that learns the full coupled system dynamics while adapting to changes in interaction context. ExoLaN combines temporal context with partial contact-force measurements from force-sensitive insoles to infer latent dynamics embeddings and estimate generalized contact torques. On seven unseen users performing 21 unseen tasks, ExoLaN reduces torque estimation MSE by 7% compared to a black-box baseline. Beyond inverse dynamics, ExoLaN serves as a unified model that also enables accurate forward prediction: training with a multi-step prediction loss reduces acceleration MSE by 59% and long-horizon position and velocity errors by 60% and 93%, respectively, compared with a single-step loss. Moreover, the learned latent context captures task information without explicit task labels, making it a promising signal for task-aware assistive control.

0.19