CS Paper Radar

Design and Validation of a Lightweight, Low-Profile Powered Knee Prosthesis with Quasi-Direct Drive Actuation

Ross J. Cortino, Ryan Posh, Emily G. Keller, Robert D. Gregg

cs.RO ·submitted 2026-09-02 02:28 UTC · v1

Abstract

Fully-powered knee prostheses, unlike traditional passive knees, can perform controlled positive work, reducing the need for compensatory behaviors by users during energy-intensive activities. While quasi-direct drive (QDD) actuators provide superior torque control, backdrivability, and acoustic noise properties compared to traditional highly-geared actuators, prior QDD prototypes have been too heavy and bulky for commercial translation. In this work, we present the design and validation of a new lightweight (2.6 kg) and low-profile (24.5 cm tip-to-tip build height) QDD knee prosthesis. By optimizing an 18 to 1 two-stage transmission alongside thermal and structural finite-element analyses, we significantly reduce device mass while enabling a peak torque of 145 Nm. Through benchtop tests, we validate the device's high output torque, low backdrive torque (1 Nm), and its precision position and torque control capabilities. We also demonstrate biomimetic kinematics and peak knee extension torques (within one standard deviation of able-bodied references) during both level-ground walking and sit-stand transitions performed by three participants with transfemoral amputation and varying K-levels. By meeting or improving upon the mass, build height, peak torque, and acoustic noise of a leading commercial powered knee, this work establishes the clinical viability of emerging QDD prostheses that promise improved dynamic performance for their users.

Comment
11 pages, 8 figures, Under Review

Closest papers

Nearest neighbours by meaning across the whole index.

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

cs.RO ·2026-10-30 ·Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang
code/data similarity 0.64
Abstract · 8 pages, 5 figures, 2 tables

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

0.22

RAIPAL: A Powerful and Agile Humanoid Arm for Human Tasks

cs.RO ·2026-11-03 ·Donggeon Kim, Hyungho Chris Choi, Donghyuk Choi, Jeongsoo Park, Choongin Lee +2 more
top venue similarity 0.61
Abstract · Published in IEEE Robotics and Automation Letters (RA-L), 2026. Supplementary video: https://youtu.be/xVUWFICD5G0

This paper presents humanoid manipulator hardware designed specifically for human-level performance throughout its broad domain of tasks, from heavy payloads to highly dynamic motions. Unlike conventional designs targeting uniform workspace capability, the proposed approach derives force, speed, and endurance targets from published measurements of task-relevant human upper-limb performance. These targets guide the actuator, mechanism, and thermal design toward torque transparency and sustained operation. The platform integrates force-oriented upper-arm components, speed-oriented forearm components, and a posture-dependent elbow mechanism that shifts its torque-speed behavior. These components are driven by planetary actuators and compact actuator-embedded electronics. Experimental results validate broad task capability, demonstrating a peak payload of 20 kg (2.25x its own mass), an endpoint speed of 20.6 m/s, and continued operation under repeated hammering impacts. Thermal analysis further confirms that the robot's sustained operation capability exceeds the published human load--duration boundary across nearly the entire load spectrum. These findings show that hardware targets derived from human-task measurements narrow the human-to-humanoid capability gap. A supplementary video is available at https://youtu.be/xVUWFICD5G0

0.48

Optimization Design and Simulation Validation of a Variable Stiffness Actuator Based on a Crossed Four-Bar Mechanism

eess.SY ·2026-09-16 ·Yuanlong Ji, Ruizhe Jiang, Xiangyu Xie, Junheng Lin, Dongrun Jin +1 more
published similarity 0.60
Abstract · 7 pages, 5 figures

This paper presents a bio-inspired antagonistic variable stiffness actuator (VSA) based on two crossed four-bar compliant transmission elastic units (CFB-CTEs). The design addresses the difficulty of combining nonlinear elastic shaping with low structural inertia in antagonistic VSA mechanisms. Inspired by the crossed constraint behavior of the anterior and posterior cruciate ligaments during knee flexion, the proposed actuator uses geometric transmission, elastic energy storage, and bilateral antagonistic arrangement to shape the output torque and equivalent stiffness. A multi-objective optimization model is established to balance torque tracking accuracy, equivalent inertia, and mass. The selected compromise design achieved a torque root-mean-square error (RMSE) of $0.883~\mathrm{N\,mm}$ and a total mass of $50.2~\mathrm{g}$. Its average equivalent inertia was reduced by about 78% compared with an independent torque-only optimized design. An ADAMS multibody model was further built to verify the structural response under single-input, opposite-input, and same-input conditions. The results support the feasibility of the proposed crossed four-bar elastic unit as a lightweight nonlinear elastic branch for antagonistic VSAs.

0.68

Design and Analysis of a Nonlinear Parallel Mechanism Coupling for Dynamic Humanoid Legs

cs.RO ·2026-10-12 ·Rohit Kumar, Heiner Peters, Felix Wiebe, Franek Stark, Janne Janzen +3 more
similarity 0.58
Abstract

Humanoids increasingly demand lightweight leg mechanisms for agile, dynamic, and energy-efficient locomotion. Reducing distal inertia through proximal actuation has thus become a common design goal. Yet, compact transmissions that preserve torque capability and efficient force transmission remain hard to achieve. This paper presents a novel series-parallel leg design combining a knee parallel mechanism, an ankle parallel mechanism, and a nonlinear knee-ankle coupling where all actuators placed closer to the hip. As the knee flexes, the coupling passively assists ankle dorsiflexion for foot clearance and, as it extends it assists plantarflexion for push-off, redistributing ankle load through the knee transmission. We derive the coupling's nonlinear transmission models and validate them in simulation and on hardware. The design shows that the shared transmission lets both joints draw on each other's actuator capacity by easing the knee's peak torque demand under load and the ankle's peak speed demand during fast motion. With the leg's proximal actuator placement, the leg achieves an effective reflected mass of 0.37 kg at the foot for a 6 kg leg, demonstrating very low distal leg inertia for dynamic humanoid robots.

0.12

Open-Source Transtibial Prosthetic Bypass Preserving Joint Alignment: Gait Learning and Kinematic Evaluation

cs.RO ·2026-11-10 ·Apolline de Vaulchier, Pablo Nocito, Yann Corbel, Nathanaël Jarrassé
code/data similarity 0.57
Abstract

Prosthetic bypasses allow able-bodied individuals to walk with a prosthesis, enabling safe early-stage testing of new prosthetic devices before clinical trials. However, existing transtibial bypasses impose constraints, such as a contralateral shoe lift or a lateral offset of the prosthesis, and their effects on gait remain poorly documented. We present an open-source transtibial prosthetic bypass that preserves part of the sagittal knee mobility without these constraints. Six able-bodied participants familiarized themselves with the bypass for approximately 10~min, then walked on a treadmill with and without it, and joint kinematics were recorded with motion capture and then extracted with OpenSim. All participants were able to walk without handrail support, although single stance remained shorter on the bypass side (27% vs. 45% of the gait cycle). Bypass-side ankle kinematics were consistent with those reported for transtibial prosthesis users, whereas peak knee flexion during swing decreased from 61° to 36° (p<0.001) and hip range of the sound leg increased from 35° to 51° (p<0.01). Although gait with the bypass does not fully replicate that of prosthesis users, it yielded consistent gait patterns after only 10~min of learning. This bypass therefore provides a useful tool for the lower-limb prosthetics research community, facilitating preliminary experiments with able-bodied participants.

0.38

Ultra-Low-Impedance Robotic Gripper for High-Bandwidth and Transparent Physical Interaction

cs.RO ·2026-08-10 ·Joon Lee, Ari Choi, Seokhwan Jeong
published similarity 0.56
Abstract · ICRA 2026 (Late Breaking Result Poster)

Conventional robotic grippers often use high-ratio transmissions to generate grasping torque and external force sensors to measure physical interaction. High-ratio transmissions increase friction, reflected inertia, and mechanical impedance, while external sensors add hardware complexity. To address these trade-offs, this study proposes a novel 9-DOF, three-fingered Differential Direct-Drive (DDD) gripper that combines DD motors with a low-ratio (1:2) differential transmission. The mechanism centralizes actuator mass at the base to minimize moving-link inertia, while the differential architecture couples two motors in parallel to amplify torque during flexion. Experiments show that the prototype delivers a nominal grasping force of approximately 18 N and a fingertip force of 4.7 N, while maintaining a low motor contribution to system inertia (0.236%) and low passive mechanical impedance, with a maximum measured value of 50.1 N/m when the motors are unpowered. The proposed hardware addresses the trade-offs among torque, physical transparency, and kinematic dexterity, providing a foundation for high-bandwidth interaction and sensorless proprioceptive force estimation.

0.19

A Dual-Cam Parallel Elastic Actuator with Shared Gas-Spring Compensation for Humanoid Ankles

cs.RO ·2026-08-31 ·Jingcheng Jiang, Yifang Zhang, Nikos G. Tsagarakis
published similarity 0.56
Abstract · Accepted to IEEE AIM 2026. Copyright 2026 IEEE. Personal use of this material is permitted

To improve torque capacity and energy efficiency of humanoid ankles, this paper proposes a 2-DoF parallel elastic actuator (PEA). The main novelty of the proposed design lies in its dual-cam, single-gas-spring architecture, which enables torque compensation in both pitch and roll using a shared elastic element, thereby improving structural compactness compared with conventional multi-element compensation schemes. By leveraging parallel gas springs and customized cam modules, the proposed architecture provides dual-axis torque assistance tailored to specific task requirements. The second key contribution is the formulation of a coupled 2-DoF mathematical model that explicitly captures the interdependence between the two compensation units through the shared spring. Based on this model, an optimization-based design framework is developed to synthesize customized cam profiles from prescribed torque references, establishing a systematic link from task requirements to hardware realization. The complete lower-leg CAD integration is presented in detail. Static FEA and kinematic simulations confirm the design's feasibility and torque-relief effectiveness. The results highlight the proposed design as a compact, customizable solution for 2-DoF humanoid ankle torque compensation.

0.48

Design and Control of a Cable-Driven Switchable Actuator with Torque/Tension Dual Modes for Exoskeletons

cs.RO eess.SY ·2026-09-20 ·YuanLong Ji, Xu Liu, Xinyuan Cai, Qihan Ye, Xiangyu Xie +6 more
top venue similarity 0.56
Abstract

Existing wearable exoskeleton architectures are typically constrained by a single mechanical output modality, providing either joint torque around an anatomical joint or linear traction along a limb-training-oriented direction, which limits adaptability to diverse training scenarios. This letter presents a cable-driven switchable actuator (CDSA) that can rapidly switch between torque and tension modes while centralizing all sensing and actuation components at the proximal drive unit. A Coupled Movable Pulley Mechanism (CMPM) provides tension amplification at the distal end-effector, while a bidirectional Cable-Driven Ratchet Mechanism (CDRM) enables mode switching and preload regulation. To eliminate the need for distal instrumentation, multi-source proximal sensors are integrated with a data-driven fusion model to estimate distal output forces. An adaptive dual-mode force control strategy based on iterative learning control (ILC) is further developed. Platform experiments demonstrate transmission efficiencies of $(92.4 \pm 2.0)\%$ and $(96.5 \pm 3.3)\%$ in the torque and tension modes, respectively, along with a tension amplification ratio of $2.77 \pm 0.10$ under tension mode. Tracking tests on simulated knee-joint gait trajectories and short-stroke tension profiles yield stable control, with RMSEs of $(4.52 \pm 0.51)\%$ and $(3.15 \pm 0.19)\%$ of the uncontrolled peak value, respectively. Finally, seated human-coupled experiments validate the system's controllable force generation in both joint-torque and linear-traction application modes.

0.40