CS Paper Radar

Open-Source Transtibial Prosthetic Bypass Preserving Joint Alignment: Gait Learning and Kinematic Evaluation

Apolline de Vaulchier, Pablo Nocito, Yann Corbel, Nathanaël Jarrassé

cs.RO ·submitted 2026-11-10 21:39 UTC · v1
code/data

Abstract

Prosthetic bypasses allow able-bodied individuals to walk with a prosthesis, enabling safe early-stage testing of new prosthetic devices before clinical trials. However, existing transtibial bypasses impose constraints, such as a contralateral shoe lift or a lateral offset of the prosthesis, and their effects on gait remain poorly documented. We present an open-source transtibial prosthetic bypass that preserves part of the sagittal knee mobility without these constraints. Six able-bodied participants familiarized themselves with the bypass for approximately 10~min, then walked on a treadmill with and without it, and joint kinematics were recorded with motion capture and then extracted with OpenSim. All participants were able to walk without handrail support, although single stance remained shorter on the bypass side (27% vs. 45% of the gait cycle). Bypass-side ankle kinematics were consistent with those reported for transtibial prosthesis users, whereas peak knee flexion during swing decreased from 61° to 36° (p<0.001) and hip range of the sound leg increased from 35° to 51° (p<0.01). Although gait with the bypass does not fully replicate that of prosthesis users, it yielded consistent gait patterns after only 10~min of learning. This bypass therefore provides a useful tool for the lower-limb prosthetics research community, facilitating preliminary experiments with able-bodied participants.

Closest papers

Nearest neighbours by meaning across the whole index.

Prosthesis-Aware 3D Human Pose Estimation: A Dataset and Benchmark for RSP Users

cs.CV ·2026-09-16 ·Yilin Wen, Kechuan Dong, Fumiya Suginaka, Ken Endo, Yusuke Sugano
top venuebenchmarkdatasetcode/data similarity 0.62
Abstract · ECCV 2026. Project page: https://ut-vision.github.io/RSP3D/

Recovering 3D human body motion from video is important for applications such as rehabilitation assessment and sports performance evaluation. For prosthesis users, this requires capturing both natural body joints and the geometry of the prosthetic device, a challenge that existing methods are not designed to address. Model-based estimators rely on body models trained on non-amputee individuals and cannot represent prosthesis geometry, while model-free methods lack body kinematic priors and are unreliable under occlusion. This challenge is particularly prominent for users of running-specific prostheses (RSPs), where the RSP has a complex curved geometry and moves dynamically during exercise. To fill this gap, we collect RSP3D, the first 3D dataset of RSP users, covering essential daily-life and exercise actions from participants with varied amputation conditions, using a multi-camera marker-based motion capture setup. We formally define the task of prosthesis-aware 3D pose estimation, evaluate representative methods in a zero-shot setting, and confirm their individual limitations. We further propose a hybrid baseline combining model-based body joint estimation with model-free RSP shape recovery, establishing a starting point for future research.

0.50

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
similarity 0.61
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30

Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods

cs.CV physics.med-ph ·2026-09-16 ·Florian Delaplace, Elodie Piche, Frédéric Chorin, Raphael Zory
similarity 0.61
Abstract

Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.

0.33

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

cs.RO ·2026-10-30 ·Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang
code/data similarity 0.59
Abstract · 8 pages, 5 figures, 2 tables

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

0.22

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.59
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.58
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

Human movement reconstruction through latent structural representations during assisted transitions and multidirectional hopping

cs.CE ·2026-10-07 ·Guilherme Manna Cesar, Ligia Yumi Mochida, Chady Ghnatios
similarity 0.58
Abstract

The quantification of three-dimensional human kinematics is fundamental to neurorehabilitation and musculoskeletal research, yet atypical posture, physical assistance, and rapid movement create conditions of partial observability. Here, we evaluate a latent-structure-informed framework combining convolutional rank-reduction autoencoding with feedforward regression to reconstruct movement from synchronized video. Three case-based demonstrations span therapist-assisted sit-to-stand in a child with cerebral palsy, unassisted sit-to-stand in a typically developing child, and multidirectional single-leg hopping in a young adult. Reconstruction was examined through positional trajectories, projected angular descriptors, and hip-knee coupling. Across test repetitions excluded from model training, mean absolute errors in a predicted marker position during assisted sit-to-stand ranged from 12.02 to 57.11 mm. Sagittal knee and trunk descriptor errors were 5.32° and 5.38° in the typically developing case. Hip-knee cyclograms captured aspects of coupled-motion patterns in both cases, with closer trajectory correspondence in the typically developing case. Sixteen test hops yielded a vertical knee-marker mean absolute error of 15.58 mm. These findings connect latent-structure-informed reconstruction with biomechanically interpretable movement features, providing a foundation for video-derived assessment spanning clinically atypical movement and high-dynamic athletic movement.

0.09

What is the effect of running-specific prostheses on long jumps? Optimization-based prediction and analysis using biomechanical models

cs.RO ·2026-08-23 ·Anna Lena Emonds, Johannes Funken, Wolfgang Potthast, Katja Mombaur
similarity 0.57
Abstract · This work has been submitted to Scientific Reports and it is currently under review

Long jumpers with below the knee amputation (BKA) that take off from their running-specific prosthesis (RSP) improved performances significantly over the last years. The long jump biomechanics differs compared to athletes without BKA and the question arises whether the spring-like properties of the RSP facilitate achieving long jumping distances. The aim of this work is to propose a long jump model for athletes with and without BKA, to evaluate it and to apply it for comparing long jump motions with and without RSP. We establish rigid multi-body system models of one athlete with and one athlete without below the knee amputation (BKA). Long jump motions are computed by solving a specific optimal control problem (OCP) with constraints enforcing a physically correct dynamics, both for motion reconstruction or motion synthesis. With the proposed long jump model, we are able to compute realistic long jump motions. We discuss the causes of differences in measured long jumps and show directions for eliminating them. For both athletes, the synthesized solutions reveal potential for performance improvement. The jumping distance of the athlete without BKA is 64cm (6.9%) longer than the one of the athlete with BKA in the synthesized solutions.

0.31