CS Paper Radar

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj, Inseung Kang

cs.RO ·submitted 2026-10-06 21:48 UTC · v1
code/data

Abstract

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

Comment
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Closest papers

Nearest neighbours by meaning across the whole index.

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

cs.RO ·2026-10-30 ·Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang
code/data similarity 0.74
Abstract · 8 pages, 5 figures, 2 tables

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

0.22

A Mode-Unified, Continuous, and Biomimetic Control Strategy of a Robotic Lower Limb Prosthesis

cs.RO ·2026-10-13 ·Hanjun Kim, Sixu Zhou, John Shim, Xinyuan Guo, Kinsey R. Herrin +1 more
code/data similarity 0.68
Abstract · This work has been submitted to a research journal for possible publication. Copyright may be transferred without notice, after which this v…

Existing biomimetic lower-limb prosthesis controllers are commonly designed for discrete locomotion modes, requiring separate parameterizations for level walking, ramps, and stairs. We present a mode-unified prosthesis control framework that represents knee and ankle biomechanics continuously as functions of terrain slope and gait phase across those locomotion conditions. Locally optimized ascent and descent polynomial models were unified using radial basis function (RBF) interpolation, preserving the accuracy of the partitioned models while outperforming a global polynomial representation. The resulting biomechanics were transformed into continuous and slope-dependent impedance parameters and implemented within a single finite-state-machine (FSM) controller using bilateral sensing for gait-state estimation. Experiments with 10 individuals with transfemoral amputation demonstrated terrain-adaptive locomotion from level walking through ramps and stairs up to 35 degrees, including 13 degree ramp and 15 degree stair conditions absent from the underlying able-bodied (AB) dataset. Experimental results reproduced the principal slope-dependent biomechanical trends predicted by the unified model, with high agreement for knee-related measures (r-square = 0.82 - 0.99) and ankle kinematics (r-square= 0.78 - 0.96). These findings demonstrated that unified biomechanical parameterization enables a prosthesis control architecture across diverse terrain conditions while preserving key features of AB biomechanics without requiring independently tuned impedance parameter sets for each locomotion mode. To facilitate reproducibility and further development, the biomechanics modeling and impedance parameterization code is publicly available at https://github.com/kim2576.

0.26

Calibration-free IMU-based Relative Orientation Estimation under Dynamic Human Motion

cs.RO eess.SY ·2026-10-22 ·Ruiyuan Li, Hassan Osman, Ajay Seth, Manon Kok
similarity 0.67
Abstract · 8 pages, 7 figures, 1 table. Submitted to IEEE Sensors Journal

Recent magnetometer-free inertial measurement unit (IMU) methods can reduce drift in joint motion estimation using rigid-body constraints, but they typically require pre-calibrated sensor locations, assumptions of specific joint models (e.g., hinge joints) or limited motion types, or an external reference for global orientation. Furthermore, challenges related to high-frequency impacts (e.g. at foot strikes during gait) and numerical differentiation of noisy measurements have not been explicitly addressed. We propose an extended Kalman filter that estimates relative IMU orientation and sensor location simultaneously, requiring neither offline sensor location calibration nor a global orientation anchor. A systematic simulation study shows that the quality of the relative orientation and the sensor location estimates depends on different motion-intensity sources: the joint center acceleration and the relative angular velocity, respectively. A low-pass filter (LPF) is used to mitigate real-signal outliers before applying the rigid-body constraint. When applied to the OpenSense dataset with real IMU measurements across four subjects with three lower-body joint types during walking and complex tasks including various motion types, the proposed method achieves an overall relative orientation error of 2.61°, compared with 10.40° for a baseline using offline-estimated sensor locations and 7.43° for a baseline using marker-derived sensor locations. These results show that the proposed calibration-free estimation framework handles real IMU data effectively and achieves accurate relative orientation without offline sensor location calibration.

0.16

Assistance Torque Estimation via Dynamics-Aware Optimization for Lower-Limb Exoskeleton in Complex Environments

cs.RO ·2026-09-14 ·Xiao-Yin Liu, Guotao Li, Weiqun Wang, Zeng-Guang Hou
similarity 0.67
Abstract · 8 pages, 11 figures, https://youtu.be/CGxDD0jKpak

Ground-truth human joint torque estimation relies on motion capture systems, which suffer from limited outdoor usability and significant deployment expenses. Furthermore, direct scaling of ground-truth joint torques to obtain motor torque commands is not necessarily the optimal strategy. To address the aforementioned limitations, inspired by the human motion generation process, this paper proposes a novel assistance torque estimation method based on the dynamic model. From an optimization perspective, the proposed method directly generates motor-assist torque and lowers the cost of data acquisition. Then, a data-driven assistance torque prediction network is trained to enable accurate real-time prediction under complex outdoor environments. Experimental results demonstrate that optimized (estimated) assistance torque exhibits better phase consistency with gait trajectories and better alignment with task characteristics. Relative to the Zero torque condition, the predicted torque can decrease metabolic rate by 11.8%-17.7%, heart rate by 8.9%-14.3%, and peak muscle activation levels by 28.2%-54.0%, respectively. This provides a new perspective for low-cost adaptive exoskeleton assistance.

0.21

Synchronized AMG and EMG Dataset of Lower-limb Muscle Activities in Everyday Training

cs.HC ·2026-08-12 ·Dongxu Tang, Shih Ying-Lei, Zhuoyi Ren, Jianting Liao, Yitian Shao
benchmarkdataset similarity 0.67
Abstract

Understanding how lower-limb muscle groups coordinate is important for studying movement impairment, rehabilitation, and physical performance. Reproducible analysis of this coordination requires multimodal recordings that relate local muscle-related signals with body-level kinematics. Complementing neural-level electrical activation captured by EMG, AMG provides a valuable mechanical approach to monitoring muscle activity. Here, we introduce a synchronized, multimodal dataset for healthy-adult lower-limb activities. For data collection on the left leg, 16 triaxial accelerometers were evenly divided into four muscle-site clusters for AMG recording, complemented by four surface EMG channels. A 15-marker optical motion-capture (MoCap) system captured lower-body kinematics, with the resulting marker trajectories used to compute bilateral knee and ankle joint angles. Our dataset contains 1,918 trials from 30 subjects across 16 task conditions. We benchmark the dataset by estimating four joint angles from 300 ms windows of the 5-100 Hz band-pass-filtered AMG data and assess matched EMG features in a separate modality ablation. In the primary cross subject benchmark, the four reference models achieved mean absolute errors of 8.840$^\circ$-9.591$^\circ$. The benchmark and ablation results characterize performance across subjects, tasks, and joint angles and examine the effects of sensor configuration, modality, the number of training subjects, and frequency representation. The release includes documented timing definitions, processed data, and reproducible benchmark resources. https://dongxutang918-afk.github.io/SAME-Limb/

0.16

Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls

cs.RO cs.LGeess.SP ·2026-11-14 ·Jiaying Xu, Guangyuan Chen, Buyun Gao, Zhen Dong
similarity 0.65
Abstract · 8 pages, 5 figures, 3 tables. Submitted to IEEE Robotics and Automation Letters (RA-L)

Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise $R^2$ from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity ($G_\mathrm{T} = +0.053$) and half as much once own other-activity data exist ($G_\mathrm{W} = +0.028$); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.

0.23

Contact-Constrained Lower-Limb Joint-Offset Calibration for Humanoid Robots

cs.RO ·2026-09-02 ·Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Chengyuan Luo +3 more
top venue similarity 0.65
Abstract

Accurate joint encoder offsets are essential for kinematic consistency in humanoid lower limbs, yet existing calibration methods typically require external motion-capture systems or fiducial targets. We present a self-contained calibration framework exploiting only onboard joint encoders and a pelvis-mounted IMU during static double-support contact. The inter-foot transform from forward kinematics must stay constant when both feet are fixed; minimizing its posture-dependent dispersion yields a nonlinear least-squares problem over the 12-dimensional offset vector. A Hessian eigenstructure analysis shows that parallel pitch axes induce a rotational coupling. Orientation residuals then observe only the pitch-offset sum, while translation and posture diversity set the remaining numerical observability. For the A3 pitch-to-roll-to-yaw ordering, hip-roll and hip-yaw excitation reduce hip-pitch coupling. A standing-posture knee prior then anchors the remaining weak pitch-chain decomposition. Simulation and real-machine injection tests show consistent recovery, and on held-out recordings calibration reduces foot-height RMS residuals from 4.26 to 2.20 mm on A3 and from 8.03 to 1.43 mm on A2. An independent LiDAR-inertial reference checks the pitch-coupled channel. Removing an injected pitch offset moves the leg-odometry vertical drift back toward the LiDAR trajectory. A few static double-support stances thus provide contact-consistent corrections for well-excited directions. Individual offsets in the weak pitch chain remain prior-dependent.

0.44

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

cs.RO ·2026-10-02 ·Neethan Ratnakumar, Mariya Tohfafarosh, Xianlian Zhou
similarity 0.65
Abstract

Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.

0.14