CS Paper Radar

Synchronized AMG and EMG Dataset of Lower-limb Muscle Activities in Everyday Training

Dongxu Tang, Shih Ying-Lei, Zhuoyi Ren, Jianting Liao, Yitian Shao

cs.HC ·submitted 2026-08-12 11:43 UTC · v1
benchmarkdataset

Abstract

Understanding how lower-limb muscle groups coordinate is important for studying movement impairment, rehabilitation, and physical performance. Reproducible analysis of this coordination requires multimodal recordings that relate local muscle-related signals with body-level kinematics. Complementing neural-level electrical activation captured by EMG, AMG provides a valuable mechanical approach to monitoring muscle activity. Here, we introduce a synchronized, multimodal dataset for healthy-adult lower-limb activities. For data collection on the left leg, 16 triaxial accelerometers were evenly divided into four muscle-site clusters for AMG recording, complemented by four surface EMG channels. A 15-marker optical motion-capture (MoCap) system captured lower-body kinematics, with the resulting marker trajectories used to compute bilateral knee and ankle joint angles. Our dataset contains 1,918 trials from 30 subjects across 16 task conditions. We benchmark the dataset by estimating four joint angles from 300 ms windows of the 5-100 Hz band-pass-filtered AMG data and assess matched EMG features in a separate modality ablation. In the primary cross subject benchmark, the four reference models achieved mean absolute errors of 8.840$^\circ$-9.591$^\circ$. The benchmark and ablation results characterize performance across subjects, tasks, and joint angles and examine the effects of sensor configuration, modality, the number of training subjects, and frequency representation. The release includes documented timing definitions, processed data, and reproducible benchmark resources. https://dongxutang918-afk.github.io/SAME-Limb/

Closest papers

Nearest neighbours by meaning across the whole index.

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.67
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

cs.RO ·2026-10-11 ·Zheng Ma, Xiao Jin, Zhenhua Yu
similarity 0.67
Abstract · 8 pages, 9 figures, 4 tables

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.

0.37

Why Personalization Matters: Cross-Subject Challenges in EMG-IMU-based HRI Activity Recognition

cs.RO ·2026-08-21 ·Ruan Rithelle Chagas de Faria Carminati, Giovanni Braglia, Luigi Biagiotti, Ronnier Frates Rohrich, Andre Schneider de Oliveira +2 more
publishedcode/data similarity 0.66
Abstract · Data collection was approved by the Federal University of Technology-Paraná Ethics Committee (CAAE 91430125.0.0000.0177). The MAGIC-HRI (Mul…

This paper investigates wearable-based recognition of human activities and gestures to support Human-Robot Interaction (HRI) in object-handover and assembly-like scenarios. Electromyography (EMG) and Inertial Measurement Unit (IMU) signals were collected using a Myo armband, culminating in a novel dataset introduced as MAGIC-HRI (Multimodal Activity, Gesture and Intention Collection) with a large taxonomy of 53 movement classes, including Brazilian Sign Language (LIBRAS) numbers (0-9), hand gestures, object/tool handover actions (pick up/give/hold), tool-manipulation tasks, and generic assembly/idle motions, collected from 11 participants with 10 samples per class (530 samples per participant). Signals are segmented by detecting muscle activation via an EMG energy envelope, then processed using sliding windows; time- and frequency-domain features are extracted. Multiple classical classifiers are tuned via cross-validated grid search, with Random Forest as the strongest baseline. A Leave-One-Subject-Out (LOSO) protocol reveals a large generalization gap, indicating substantial subject dependence. A personalized adaptation experiment suggests that injecting a small number of samples from a new user can markedly improve recognition. Overall, the study contributes a broad, HRI-driven multimodal dataset, a rigorous evaluation emphasizing generalization, and practical evidence that personalization is likely required for robust deployment in practical HRI.

0.33

Pose2Muscle: Structured Spatio-Temporal Decoding for Discrete Muscle Activity Estimation from Human Pose

cs.CV ·2026-09-16 ·Yuepeng Chen, Jiehong Shi, Kaili Zheng, Boyi Zhang, Chenyi Guo +2 more
dataset similarity 0.64
Abstract

Muscle activity is fundamental to human movement, and understanding its patterns is critical for injury prevention and rehabilitation. Conventional muscle activity monitoring relies on specialized sensors such as surface electromyography, which limits its practicality for long-term real-world use. Existing studies suggest that muscle-related information can be inferred from human pose. However, the substantial gap between externally observable pose and internal muscle activation, limits the accuracy and generalization of current approaches. In this study, we propose Pose2Muscle, a pose-driven framework for discrete muscle activity estimation without requiring sEMG signals at inference time. Instead of directly regressing continuous sEMG signals, Pose2Muscle reformulates muscle estimation as a structured prediction problem over discrete muscle activity states, yielding a more stable and interpretable target space. The framework combines multi-scale spatio-temporal attention to capture motion patterns at complementary spatial and temporal scales with a directed acyclic graph-based decoder that maintains multiple candidate muscle-state hypotheses and performs structured trajectory inference over time. To support this task, we construct PoseEMG-43, a synchronized pose-sEMG dataset containing 2,992 movement instances from 43 daily-life actions performed by 14 participants. Experiments show that Pose2Muscle consistently outperforms representative retrieval- and pose-based baselines. It achieves an Adjacent-level Accuracy of 86.36% and a Pearson correlation coefficient of 0.8821 under the Random Split, and 63.97% and 0.6795, respectively, under the Subject-Level Split. These results demonstrate the feasibility of inferring structured muscle-state patterns from human pose and suggest the potential of Pose2Muscle for muscle-aware movement analysis when direct physiological sensing is impractical

0.28

Autonomous Telerehabilitation via Skeletal Motion Prediction and Joint-Level Performance Assessment

cs.CV cs.LG ·2026-08-12 ·Lara Pereira, João Ruivo Paulo, Pedro Santos, Paulo Peixoto
published similarity 0.64
Abstract · Accepted at IEEE RO-MAN2026

Autonomous rehabilitation systems must not only recognize human motion but also provide structured feedback to support users without continuous therapist supervision. This paper presents a telerehabilitation pipeline that integrates skeleton-based exercise quality assessment and short-term motion prediction into a two-module system operating on marker-free RGB video. A self-attentive Bidirectional LSTM performs exercise quality classification using MMD-NCA metric learning, while a graph-based motion prediction module computes per-joint position errors between predicted and observed poses, generating spatially localized deviation signals. Each module is evaluated independently on established benchmarks: the classifier achieves 96.45% mean-class accuracy on squat sequences from the PROZIS dataset, and the adopted STARS predictor achieves a mean MPJPE of 75.8 mm at 560 ms on Human3.6M, outperforming graph and recurrent baselines across all prediction horizons. The framework is designed for eventual deployment in assistive robotics and home-based rehabilitation contexts; end-to-end integration and clinical validation are important directions for future work. By combining motion recognition and prediction in a single system, this work contributes a step toward autonomous, feedback-driven telerehabilitation, for more accessible and scalable rehabilitation solutions.

0.23

Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls

cs.RO cs.LGeess.SP ·2026-11-14 ·Jiaying Xu, Guangyuan Chen, Buyun Gao, Zhen Dong
similarity 0.64
Abstract · 8 pages, 5 figures, 3 tables. Submitted to IEEE Robotics and Automation Letters (RA-L)

Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise $R^2$ from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity ($G_\mathrm{T} = +0.053$) and half as much once own other-activity data exist ($G_\mathrm{W} = +0.028$); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.

0.18

IMU-Bench: Benchmarking Wrist IMU Representations Across Kinematic, Semantic and Clinical Tasks

cs.RO cs.AI ·2026-10-14 ·Yiquan Li, Aidan Bradshaw, Chenfeng Gao, Karan Ahuja
benchmarkcode/data similarity 0.64
Abstract

Wrist-worn inertial measurement units (IMUs) provide a common sensing modality for tasks ranging from activity and gesture recognition to pose estimation, inertial odometry and clinical motor assessment. Existing wearable benchmarks evaluate performance across multiple tasks, but leave open how supervision for one task affects transfer to others and whether these tasks benefit from a shared representation. We present IMU-Bench, a benchmark of ten tasks from eight datasets for studying IMU multi-task performance and cross-task transfer. We compare six self-supervised methods pretrained on unlabeled recorded and simulated wrist motion, evaluating classification, pose and velocity estimation, and IMU-language retrieval. We find that our masked autoencoder, InrtlWrist, achieves the best or joint-best frozen-probe performance on nine of ten tasks, and fine-tuning improves on training from scratch on nine of ten tasks, including full-body pose, odometry and retrieval. Across transfer and joint-training experiments, supervision that benefits one target can reduce performance on others, with supervised sources transferring within kinematic estimation while, under frozen probing, none approaches the pretrained encoder on language retrieval, and joint-training gains that come at a cost to the paired task. These findings distinguish broad downstream usefulness from complementary task supervision. Code, task cards and a leaderboard are publicly available.

0.17

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.62
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.20