CS Paper Radar

Contact-Constrained Lower-Limb Joint-Offset Calibration for Humanoid Robots

Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Chengyuan Luo, Enyu Li, Peiwen Lin, Chuang Wang

cs.RO ·submitted 2026-09-02 08:51 UTC · v2
top venue

Abstract

Accurate joint encoder offsets are essential for kinematic consistency in humanoid lower limbs, yet existing calibration methods typically require external motion-capture systems or fiducial targets. We present a self-contained calibration framework exploiting only onboard joint encoders and a pelvis-mounted IMU during static double-support contact. The inter-foot transform from forward kinematics must stay constant when both feet are fixed; minimizing its posture-dependent dispersion yields a nonlinear least-squares problem over the 12-dimensional offset vector. A Hessian eigenstructure analysis shows that parallel pitch axes induce a rotational coupling. Orientation residuals then observe only the pitch-offset sum, while translation and posture diversity set the remaining numerical observability. For the A3 pitch-to-roll-to-yaw ordering, hip-roll and hip-yaw excitation reduce hip-pitch coupling. A standing-posture knee prior then anchors the remaining weak pitch-chain decomposition. Simulation and real-machine injection tests show consistent recovery, and on held-out recordings calibration reduces foot-height RMS residuals from 4.26 to 2.20 mm on A3 and from 8.03 to 1.43 mm on A2. An independent LiDAR-inertial reference checks the pitch-coupled channel. Removing an injected pitch offset moves the leg-odometry vertical drift back toward the LiDAR trajectory. A few static double-support stances thus provide contact-consistent corrections for well-excited directions. Individual offsets in the weak pitch chain remain prior-dependent.

Closest papers

Nearest neighbours by meaning across the whole index.

OmniCalib: Target-Free, Task-Structured Self-Calibration for Humanoid Robots

cs.RO ·2026-09-17 ·Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Enyu Li +4 more
similarity 0.66
Abstract · 6 figures, 3 tables

Assembly, wear, and component replacement perturb the sensor extrinsics and joint zeros encoded by a humanoid CAD model. Existing procedures calibrate one sensor pair or require external fiducials. Using only robot-native motion and onboard sensing, we present OmniCalib, a target-free workflow that calibrates the full upper limbs---all 14 arm joint zeros and the extrinsics of both wrist and chest cameras---as well as lower limbs and the multi-camera head rig. Each module matches a robot-native task to a parameter block, checks observability, and writes only supported corrections to the CAD model. Our depth ICP method recovers all 14 arm joint zeros and calibrates all RGB-D camera extrinsics without any calibration target. Relative to CAD, the estimated extrinsic corrections are 10.56 mm and 1.74 degrees for the left wrist, 6.33 mm and 1.25 degrees for the right wrist, and 9.81 mm and 0.929 degrees for the chest RGB-D camera. ICP point-to-plane residual is 2.09 mm. On the same injected offsets, ICP and ArUco recover all 14 joint zeros below the 0.1-degree encoder-resolution reference. On an AGIBOT A3 Ultra humanoid, four static double-support stances recover all 12 lower-limb joint-zero offsets injected with an RMS error of 0.063 degrees. The head module combines multi-camera visual odometry with legged odometry and dynamic compensation through the live ROS transform tree. Using only planar walking, it attains a mean SO(3) error of 1.061 degrees across three sequences. The best sequence reaches 0.775 degrees, competitive with iKalibr at 0.902 degrees from rich 6-DOF excitation. Rig-relative angles repeat within 0.140 degrees. Injection recovery and held-out tests validate each observable block.

0.25

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.65
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.48

Calibration-free IMU-based Relative Orientation Estimation under Dynamic Human Motion

cs.RO eess.SY ·2026-10-22 ·Ruiyuan Li, Hassan Osman, Ajay Seth, Manon Kok
similarity 0.64
Abstract · 8 pages, 7 figures, 1 table. Submitted to IEEE Sensors Journal

Recent magnetometer-free inertial measurement unit (IMU) methods can reduce drift in joint motion estimation using rigid-body constraints, but they typically require pre-calibrated sensor locations, assumptions of specific joint models (e.g., hinge joints) or limited motion types, or an external reference for global orientation. Furthermore, challenges related to high-frequency impacts (e.g. at foot strikes during gait) and numerical differentiation of noisy measurements have not been explicitly addressed. We propose an extended Kalman filter that estimates relative IMU orientation and sensor location simultaneously, requiring neither offline sensor location calibration nor a global orientation anchor. A systematic simulation study shows that the quality of the relative orientation and the sensor location estimates depends on different motion-intensity sources: the joint center acceleration and the relative angular velocity, respectively. A low-pass filter (LPF) is used to mitigate real-signal outliers before applying the rigid-body constraint. When applied to the OpenSense dataset with real IMU measurements across four subjects with three lower-body joint types during walking and complex tasks including various motion types, the proposed method achieves an overall relative orientation error of 2.61°, compared with 10.40° for a baseline using offline-estimated sensor locations and 7.43° for a baseline using marker-derived sensor locations. These results show that the proposed calibration-free estimation framework handles real IMU data effectively and achieves accurate relative orientation without offline sensor location calibration.

0.16

Learning Accurate End-Effector Trajectory Tracking with Inertial Feedback for a Quadruped Manipulator

cs.RO ·2026-11-17 ·Dohyeon Kim, Seungyong Han, Yeongtae Jung
similarity 0.63
Abstract

Accurate end-effector trajectory tracking on quadruped manipulators is challenging because uncertainties in actuators, foot-ground contact, and geometric errors are propagated through the leg-arm kinematic chain. Detecting such errors requires sensing beyond joint encoders that can capture the effects of these uncertainties on the robot's motion, since joint encoders only provide measurements at the actuated joints and cannot fully observe mechanical errors such as backlash, dimensional inaccuracies, or structural deformation. This work addresses these challenges using a reinforcement learning framework with end-effector (EE) inertial feedback, targeting local high-accuracy manipulation while maintaining a nominal body pose and support configuration without intentional body motion or foot repositioning. The learned policy uses EE inertial measurements to compensate for tracking errors induced by uncertainties throughout the leg-arm system that cannot be fully inferred from proprioception alone. Simulation and real-world experiments on continuous EE trajectory tracking show overall improvements relative to nominal and proprioception-only baselines. In real-world experiments, the proposed policy reduces the MoCap-based RMSE by 17.3% and 28.0% relative to the nominal baseline under the two in-distribution (ID) command conditions, respectively, and by an additional 12.6% and 15.9% relative to the proprioception-only baseline. Furthermore, the trajectory-wise RMSE between FK-reconstructed and motion-capture-measured end-effector positions averaged 12.61+-2.15mm (mean+-standard deviation) across 24 controller-trajectory combinations, revealing a substantial discrepancy between nominal kinematic reconstruction and measured end-effector motion.

0.22

SG-ODOM: Event-Driven Proprioceptive State Estimation with Stability-Gated Contact Updates for Legged Robots

cs.RO ·2026-11-16 ·Francesco Iotti, Chiyun Noh, Franco Angelini, Manolo Garabini, Ayoung Kim +2 more
code/data similarity 0.62
Abstract

Reliable proprioceptive state estimation for legged robots fuses inertial sensing with kinematic sensing from leg encoders. The latter assumes a foot is stationary during the stance phase; however, physical foot touchdown does not necessarily provide a stationary reference for odometry, particularly during impact and load transfer. Repeatedly applying kinematic corrections throughout the same contact phase can introduce redundant or unreliable information. We present SG-ODOM, a proprioceptive odometry framework that uses stability-gated contact selection to schedule kinematic updates. Following physical touchdown, a stability gate accepts the contact for state estimation only after the foot reaches a sufficiently stable support condition. The resulting validated touchdown event triggers an estimator correction, while additional timeout updates bound the maximum duration of uninterrupted IMU propagation. The framework is evaluated on multiple legged platforms, both quadrupedal and humanoid robots, against representative state-of-the-art proprioceptive estimators. Across the evaluated sequences, SG-ODOM demonstrates competitive or superior estimation accuracy, reducing Relative Pose Error (RPE) by up to 25% compared to the baseline estimator on outdoor sequences from the GrandTour dataset. Source code: https://github.com/ori-drs/SG-ODOM. Video: https://youtu.be/-583_RyuhqQ

0.38

Contact-UAN: Unsupervised Actuator Networks as a Residual World Model for Humanoid Control

cs.RO ·2026-10-13 ·Nolan Fey, Khai Nguyen, Yash Prabhu, Gabriel B. Margolis, Pulkit Agrawal
similarity 0.62
Abstract · Project website: https://contact-uan.csail.mit.edu/

Humanoid policies trained in simulation can transfer qualitatively to hardware while failing to transfer the force interactions learned during training, compromising torque efficiency, load regulation, and robustness to impacts. This failure can arise from actuator sim-to-real gaps because forces depend on actuator torques. We introduce Contact-UAN, a residual world model that preserves a simulator's physics priors while correcting actuator dynamics to align simulated rollouts with recorded hardware rollouts. For humanoid motion with contact, this requires contact-consistent replay: if hardware playback in simulation begins with misaligned contact wrenches, the residual model learns to correct reset artifacts rather than actuator discrepancies. Using only onboard proprioception, Contact-UAN infers the simulator-side stance-foot pose needed to initialize replay with consistent contact forces. We show that a UAN trained on 6.5 minutes of real-world walking data generalizes to tasks that benefit from accurate force and impulse regulation and produces policies that transfer seamlessly to the real world, yielding 20% lower running torque, 43% lower force-tracking error, extreme compliance, accurate impedance control, and dynamic, robust jumps.

0.28

A2I-Calib++: A Kinematics-Driven Anti-noise Active Calibration Framework for Whole-Body Multi-IMU Systems on Legged Robots

cs.RO ·2026-10-21 ·Fangyu Jiang, Chaoran Xiong, Kehui Ma, Zhen Sun, Zeyu Zhang +1 more
similarity 0.62
Abstract

Recently, multi-node inertial measurement unit (multi-IMU) systems have shown promise for robust odometry in legged robots. Multi-IMU fusion can improve legged robot odometry but requires accurate spatiotemporal calibration among the sensors. Existing multi-IMU calibration methods, designed for aerial or handheld platforms, face challenges on legged robots because routine locomotion may provide insufficient excitation, while foot slips, impacts, and vibrations introduce measurement disturbances. To address these challenges, we propose A2I-Calib++, a kinematics-driven anti-noise active calibration framework for body-mounted IMUs covered by the robot kinematic model. It estimates temporal offsets, extrinsic rotations and translations, and inertial biases through temporal correlation search followed by analytic spatial and bias estimation, without artificial calibration targets or complex parameter tuning for the target IMU. A2I-Calib++ comprises three core modules: 1) a Noise-Isotropy-Inspired Trajectory supported by a finite-horizon conditioning proposition that generates sufficient excitation to limit noise sensitivity; 2) a constraint-aware Adversarial Motion Priors controller that combines the anti-noise excitation with a rolling-contact reward for contact-aware execution; and 3) a contact-constrained virtual IMU that fuses pre-calibrated calf IMUs and joint kinematics under a rolling-contact model to construct the calibration reference. Furthermore, evaluations on both simulation and real-world quadruped platforms demonstrate notably reduced noise sensitivity and simulation calibration errors compared to conventional methods, together with repeatable real-world calibration and improved proprioceptive odometry accuracy for legged robots.

0.16

Dataset-Free Compliant Humanoid Loco-Manipulation with Dynamic Online Posture

cs.RO ·2026-10-05 ·Seungho Yeom, Zhenyu Wu, Jaeyoung Huh, Diego Williams, Yuheng Zhi +2 more
similarity 0.62
Abstract

Most humanoid loco-manipulation controllers require human motion data to learn whole-body coordination and posture, leaving policies reliant on external sources to provide this data. We present OCLO (Online-posture Compliant LOco-manipulation), a humanoid loco-manipulation system trained without human motion data and commanded only through two end-effector targets. Because these targets do not uniquely determine whole-body posture, OCLO generates pelvis height and torso orientation online using an analytic reachability prior, further refined through policy-in-the-loop sampling with a task-agnostic cost. OCLO also learns whole-body compliance by displacing end-effector references according to measured forces through a spring-damper model, encouraging the legs, waist, and pelvis to yield to external loads. In simulation, using the reachability prior leads to a 77.8% success rate in acquiring the commanded reference, a vast improvement over the 37.8% success rate accomplished without the prior. Further, refinement reduces end-effector orientation error across all evaluated tasks. The same posture module improves a pretrained SONIC controller on four of five tasks. Without compliance training, policies tend to lose balance under disturbances rather than sacrifice tracking. On a Unitree G1, OCLO maintains balance under end-effector disturbances that cause its ablations to fail and performs seven loco-manipulation tasks, including crouched walking and picking up a box from a low surface. Project website: https://oclo-humanoid.github.io/

0.27