Abstract

Recent magnetometer-free inertial measurement unit (IMU) methods can reduce drift in joint motion estimation using rigid-body constraints, but they typically require pre-calibrated sensor locations, assumptions of specific joint models (e.g., hinge joints) or limited motion types, or an external reference for global orientation. Furthermore, challenges related to high-frequency impacts (e.g. at foot strikes during gait) and numerical differentiation of noisy measurements have not been explicitly addressed. We propose an extended Kalman filter that estimates relative IMU orientation and sensor location simultaneously, requiring neither offline sensor location calibration nor a global orientation anchor. A systematic simulation study shows that the quality of the relative orientation and the sensor location estimates depends on different motion-intensity sources: the joint center acceleration and the relative angular velocity, respectively. A low-pass filter (LPF) is used to mitigate real-signal outliers before applying the rigid-body constraint. When applied to the OpenSense dataset with real IMU measurements across four subjects with three lower-body joint types during walking and complex tasks including various motion types, the proposed method achieves an overall relative orientation error of 2.61°, compared with 10.40° for a baseline using offline-estimated sensor locations and 7.43° for a baseline using marker-derived sensor locations. These results show that the proposed calibration-free estimation framework handles real IMU data effectively and achieves accurate relative orientation without offline sensor location calibration.

Comment
8 pages, 7 figures, 1 table. Submitted to IEEE Sensors Journal

Closest papers

Nearest neighbours by meaning across the whole index.

Rotation-Invariant Multi-IMU Activity Recognition under Independent Per-Location Orientation Shifts

cs.AI cs.LG ·2026-08-16 ·Seungyeol Baek, Yoonbyung Chai, Yonghyeon Lee, Sungjoon Choi, Sungho Suh
published similarity 0.68
Abstract · 6 pages, 2 figures. ACM International Symposium on Wearable Computing (ISWC) 2026

Human Activity Recognition (HAR) with self-administered wearables, such as at-home rehabilitation and exercise monitoring, often requires reattaching inertial measurement units (IMUs) across sessions. In multi-IMU settings, this can induce independent orientation offsets across body locations, a deployment shift that conventional scalar HAR models do not structurally handle. Existing remedies rely on rotation augmentation, whose robustness depends on sampled transformations, or calibration and orientationnormalization pipelines requiring additional reference-frame assumptions or explicit procedures. We present Truly Rotation-Invariant HAR (TRI-HAR), a rotation-invariant framework that makes robustness to independent per-location IMU orientation offsets a structural model property. TRI-HAR reshapes accelerometer and gyroscope streams into triaxial vectors, applies a shared SO(3)-equivariant backbone and invariant projection to each IMU location, and fuses the resulting invariant features for activity classification. Across four multi-IMU benchmarks, TRI-HAR preserves macro-F1 under fixed independent per-location SO(3) rotations and outperforms rotation-augmented baselines under this target shift without requiring rotational augmentation.

0.58

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.67
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.48

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

cs.RO ·2026-10-14 ·Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie +1 more
dataset similarity 0.66
Abstract · 8 pages, 5 figures

Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.

0.26

A2I-Calib++: A Kinematics-Driven Anti-noise Active Calibration Framework for Whole-Body Multi-IMU Systems on Legged Robots

cs.RO ·2026-10-21 ·Fangyu Jiang, Chaoran Xiong, Kehui Ma, Zhen Sun, Zeyu Zhang +1 more
similarity 0.65
Abstract

Recently, multi-node inertial measurement unit (multi-IMU) systems have shown promise for robust odometry in legged robots. Multi-IMU fusion can improve legged robot odometry but requires accurate spatiotemporal calibration among the sensors. Existing multi-IMU calibration methods, designed for aerial or handheld platforms, face challenges on legged robots because routine locomotion may provide insufficient excitation, while foot slips, impacts, and vibrations introduce measurement disturbances. To address these challenges, we propose A2I-Calib++, a kinematics-driven anti-noise active calibration framework for body-mounted IMUs covered by the robot kinematic model. It estimates temporal offsets, extrinsic rotations and translations, and inertial biases through temporal correlation search followed by analytic spatial and bias estimation, without artificial calibration targets or complex parameter tuning for the target IMU. A2I-Calib++ comprises three core modules: 1) a Noise-Isotropy-Inspired Trajectory supported by a finite-horizon conditioning proposition that generates sufficient excitation to limit noise sensitivity; 2) a constraint-aware Adversarial Motion Priors controller that combines the anti-noise excitation with a rolling-contact reward for contact-aware execution; and 3) a contact-constrained virtual IMU that fuses pre-calibrated calf IMUs and joint kinematics under a rolling-contact model to construct the calibration reference. Furthermore, evaluations on both simulation and real-world quadruped platforms demonstrate notably reduced noise sensitivity and simulation calibration errors compared to conventional methods, together with repeatable real-world calibration and improved proprioceptive odometry accuracy for legged robots.

0.16

Wear and Go: Calibration Free Sparse Inertial Motion Capture via Online Sensor Setup Estimation

cs.CV ·2026-11-17 ·Yuanshuo Tan, Licheng Zhong
similarity 0.65
Abstract

Sparse inertial motion capture typically assumes that each sensor's anatomical identity and mounting orientation are known. We present MOSAIC (Motion-based Sensor Assignment and Inertial Calibration), a framework that recovers this setup from ordinary motion without a calibration pose. Our central insight is that body pose changes continuously while the sensor setup persists, allowing movements that are individually ambiguous to provide complementary evidence over time. A setup network processes unordered sensor streams with temporal and cross-sensor attention, then accumulates assignment and rotation evidence into a session-level estimate. The recovered setup canonicalizes measurements for frozen pretrained pose estimators, separating sensor configuration from motion reconstruction. For sensors worn at prescribed body sites, evaluation on real inertial recordings with randomized setups shows near-calibrated pose accuracy for bounded offsets and substantial benefits from accumulation under arbitrary orientations. Transfer across pose networks supports setup recovery as a reusable interface between interchangeable sensors and pretrained pose models.

0.26

Contact-Constrained Lower-Limb Joint-Offset Calibration for Humanoid Robots

cs.RO ·2026-09-02 ·Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Chengyuan Luo +3 more
top venue similarity 0.64
Abstract

Accurate joint encoder offsets are essential for kinematic consistency in humanoid lower limbs, yet existing calibration methods typically require external motion-capture systems or fiducial targets. We present a self-contained calibration framework exploiting only onboard joint encoders and a pelvis-mounted IMU during static double-support contact. The inter-foot transform from forward kinematics must stay constant when both feet are fixed; minimizing its posture-dependent dispersion yields a nonlinear least-squares problem over the 12-dimensional offset vector. A Hessian eigenstructure analysis shows that parallel pitch axes induce a rotational coupling. Orientation residuals then observe only the pitch-offset sum, while translation and posture diversity set the remaining numerical observability. For the A3 pitch-to-roll-to-yaw ordering, hip-roll and hip-yaw excitation reduce hip-pitch coupling. A standing-posture knee prior then anchors the remaining weak pitch-chain decomposition. Simulation and real-machine injection tests show consistent recovery, and on held-out recordings calibration reduces foot-height RMS residuals from 4.26 to 2.20 mm on A3 and from 8.03 to 1.43 mm on A2. An independent LiDAR-inertial reference checks the pitch-coupled channel. Removing an injected pitch offset moves the leg-odometry vertical drift back toward the LiDAR trajectory. A few static double-support stances thus provide contact-consistent corrections for well-excited directions. Individual offsets in the weak pitch chain remain prior-dependent.

0.44

LAG-IO: Multi-IMU State Estimation for Legged Robots Using Factor Graphs

cs.RO ·2026-10-13 ·Yicheng Zhou, Longwen Chen, Qinghua Yu, Junhao Xiao, Huimin Lu +1 more
similarity 0.63
Abstract

Robust proprioceptive state estimation is crucial for legged robots, particularly in challenging environments where exteroceptive sensors are unreliable. While traditional leg odometry typically relies on a single body-mounted inertial measurement unit (IMU) fused with leg kinematics via an extended Kalman filter (EKF), such methods are vulnerable to linearization errors and hard-contact assumptions, leading to severe drift during slippage or dynamic locomotion.In this paper, we propose LAG-IO, a factor graph-based multi-IMU state estimation framework that tightly couples measurements from a main body IMU, multiple leg-mounted IMUs, and joint encoders within a sliding-window optimization. To handle non-stationary foot-ground interactions, we introduce a continuous probabilistic contact detection module based on kernel density estimation (KDE), which adaptively scales the covariance of zero-velocity update (ZUPT) factors. Furthermore, kinematic relative position factors are formulated to structurally anchor the independent leg inertial states to the robot's main body. Experimental results on a quadruped robot across various unstructured terrains demonstrate that, compared to existing baselines, LAG-IO achieves higher planar trajectory accuracy, reduces unobservable vertical divergence, and provides smoother trajectory transitions during unstable contacts, while maintaining competitive attitude observability.

0.30

A Black-Box Positioning Solution for Effortless Integration in Wearable Navigation

cs.RO cs.AR ·2026-10-15 ·Anh-Van Vu, Changmin Sung, Dongsoo Han
published similarity 0.63
Abstract · 8 pages

Accurate localization is critical for a wide range of applications, including navigation, augmented reality, safety management, and healthcare. However, achieving accurate positioning remains challenging, especially in GPS-degraded environments. Pedestrian Dead Reckoning (PDR), which estimates position based on inertial sensor data, offers a promising alternative but typically demands substantial effort in algorithm design and system integration. This complexity often leads to prolonged development timelines and elevated costs. To address these challenges, we present the PDR Sensor (PDRS), a plug-and-play, black-box PDR module optimized for seamless integration into wearable and IoT platforms. PDRS integrates a microprocessor and an inertial measurement unit (IMU) within a compact, low-power module. It executes real-time sensor fusion onboard, providing position updates via standard interfaces (I2C, SPI, UART). Experimental evaluations demonstrate its high robustness, achieving a step detection error of just 0.16% over 1250 steps and a traveled distance error of 1.87% under diverse conditions. The system further exhibits low latency (2.5 ms) and modest power consumption (52.35 mA). Unlike conventional studies, the PDRS leverages a holistic co-design of hardware and software to enhance performance and integration aspects, simplifying adoption without requiring deep expertise. By lowering technical barriers, PDRS enables developers and researchers to prioritize innovation in IoT and wearable technologies, accelerating prototyping, reducing development time, and advancing industry progress. Future work aims to enhance accuracy, reduce power usage and module size, and integrate AI-driven techniques to better mitigate drift.