CS Paper Radar

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

Neethan Ratnakumar, Mariya Tohfafarosh, Xianlian Zhou

cs.RO ·submitted 2026-10-02 08:24 UTC · v2

Abstract

Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.

Closest papers

Nearest neighbours by meaning across the whole index.

Effects of Assistance Delay on Joint Mechanics and Energetics in Biological Torque Control of a Hip Exoskeleton

cs.RO ·2026-09-21 ·Jimin An, Ryan Lee, Jingshu Peng, Eni Halilaj, Inseung Kang
similarity 0.69
Abstract · 8 Pages, 4 figures

Biological torque control directly maps an estimated human joint moment to exoskeleton assistance, providing a task-agnostic strategy for supporting diverse locomotor activities. However, it remains unclear whether a fixed state-to-torque mapping provides effective assistance across biomechanically distinct tasks. We examined how assistance delay affected hip exoskeleton performance during level-ground (LG), ramp-ascent (RA), and ramp-descent (RD) walking. Eight participants completed a zero-torque baseline condition and five active assistance conditions with delays ranging from 40 to 320 ms. Across tasks and active delays, assistance reduced net metabolic rate by 5.24%, positive biological hip joint work by 5.86%, and total lower-limb positive joint work by 1.68% (all p < 0.05). Assistance delay affected both joint-work outcomes (both p < 0.001) but not net metabolic rate. Mechanical unloading generally decreased with increasing delay, whereas metabolic benefits remained comparatively stable. Relative to the zero-torque condition, net metabolic rate decreased by 9.75% during LG and 7.20% during RA but increased by 1.23% during RD. We did not detect task-dependent differences in the delay response. Our findings indicate that biological torque mappings should be evaluated based on the target outcome and mechanical role of the assisted joint, and that predominantly positive-power assistance may not generalize to negative-work-dominant locomotion without modification.

0.32

Multi-Agent Reinforcement Learning of Co-Adaptive Hip Exoskeleton Control (MARL-Exo) for Metabolic Energy Reduction

cs.RO cs.LG ·2026-10-27 ·Yifei Yuan, Jakob Wolf, Ghaith Androwis, Xianlian Zhou
similarity 0.68
Abstract · 14 pages, 6 figures, including supplementary material

Objective: This study aims to determine whether a hip-exoskeleton policy trained in simulation, by co-adapting with a musculoskeletal human model under a metabolic-energy reward, reduces the metabolic cost of walking in new users without per-user tuning, and how mechanical-power shaping affects the learned assistance. Methods: We developed MARL-Exo, a multi-agent reinforcement learning framework in which a full-body human model (304 muscle actuators; randomized anatomy, gait, and speed) and a bilateral hip-exoskeleton policy are trained concurrently in two stages. The exoskeleton observes only delayed hip kinematics and its past commands; its reward includes muscle metabolic power from a physiologically based energetics model, alone (Metabolic) or with mechanical-power shaping (Metabolic + Power). The Metabolic policy was deployed and tested without retraining in eight healthy adults walking at 1.25 m/s, using indirect calorimetry. Results: In simulation, the Metabolic policy reduced modeled muscle metabolic power by 13.8% relative to no-device walking, versus 8.8% for Metabolic + Power. On hardware, MARL-Exo reduced net metabolic rate by 18.3 $\pm$ 6.6% relative to Passive in all eight participants. Relative to No-Exo, the mean reduction was 7.4 $\pm$ 10.0%; six participants more than offset the 13.1% device-wearing penalty, walking up to 24.2% below their No-Exo cost. Conclusion: A metabolically informed policy co-adapted in simulation transferred to users without per-user tuning and consistently reduced the metabolic cost of walking with the device, while explicit power shaping reduced the simulated benefit. Significance: Unlike per-user human-in-the-loop optimization, this approach yields a single population-level controller and allows assistance objectives to be screened in simulation before human testing.

0.29

Assistance Torque Estimation via Dynamics-Aware Optimization for Lower-Limb Exoskeleton in Complex Environments

cs.RO ·2026-09-14 ·Xiao-Yin Liu, Guotao Li, Weiqun Wang, Zeng-Guang Hou
similarity 0.67
Abstract · 8 pages, 11 figures, https://youtu.be/CGxDD0jKpak

Ground-truth human joint torque estimation relies on motion capture systems, which suffer from limited outdoor usability and significant deployment expenses. Furthermore, direct scaling of ground-truth joint torques to obtain motor torque commands is not necessarily the optimal strategy. To address the aforementioned limitations, inspired by the human motion generation process, this paper proposes a novel assistance torque estimation method based on the dynamic model. From an optimization perspective, the proposed method directly generates motor-assist torque and lowers the cost of data acquisition. Then, a data-driven assistance torque prediction network is trained to enable accurate real-time prediction under complex outdoor environments. Experimental results demonstrate that optimized (estimated) assistance torque exhibits better phase consistency with gait trajectories and better alignment with task characteristics. Relative to the Zero torque condition, the predicted torque can decrease metabolic rate by 11.8%-17.7%, heart rate by 8.9%-14.3%, and peak muscle activation levels by 28.2%-54.0%, respectively. This provides a new perspective for low-cost adaptive exoskeleton assistance.

0.21

A Personalized Dynamic Balance Evaluation Paradigm for Hip Exoskeleton-Assisted Walking under Unexpected Ground Perturbations

cs.RO cs.LGeess.SY ·2026-09-13 ·Yun Chen, Oluwasegun T. Akinniyi, Qiang Zhang
published similarity 0.65
Abstract · 8 pages, 6 figures. Accepted to the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Hip exoskeletons may improve recovery from unexpected gait perturbations, yet personalizing assistance remains difficult because balance is multidimensional and human-in-the-loop experiments are small-sample and noisy. We present a participant-specific composite balance cost that integrates seven biomechanical sub-metrics spanning margin of stability, center-of-mass dynamics, and whole-body angular momentum. The sub-metrics are converted to direction-aligned, dimensionless cost features, and nonnegative fusion weights are learned on the simplex. Coupled with an empirical-Bayes hierarchical model, the learned-composite selector estimates each tested condition's posterior probability of being best, P(best), and a high-probability candidate set with size $K_{0.8}$. The framework was evaluated with three participants walking at 1.1 m/s during unilateral belt-slip perturbations across 46 hip-assistance conditions. In the full-budget analysis (B = 4 repeats per condition), the selector concentrated 80% of the posterior probability within 1 to 5 of 46 conditions, compared with 2 to 12 for equal-weight fusion and 4 to 37 for principal component analysis fusion. This smaller candidate set could shorten personalization experiments and limit participants' exposure to repeated perturbations in future studies. Selected-condition trials showed lower observed composite costs than no-torque trials, with nominal p < 0.05 for P2 and P3. Leave-one-repeat-out refits yielded positive mean held-out rank correlations for all participants and moderate stability of the learned weights and candidate sets. These proof-of-concept results support participant-specific composite balance evaluation for candidate selection in perturbation-based human-in-the-loop experiments.

0.45

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.65
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Learning a Speed-adaptive Hip Exoskeleton Control Policy Via Sim-to-real Reinforcement Learning

cs.RO ·2026-09-23 ·Bin Li, Zhimin Hou, Jiacheng Hou, Zenian Liang, Tong Wu +2 more
similarity 0.61
Abstract

Providing personalized exoskeleton assistance across varying walking speeds remains challenging. Existing online optimization methods are sample-inefficient, requiring extensive human-in-the-loop (HIL) evaluations to optimize the entire assistive torque profile. Sim-to-real reinforcement learning (RL) offers a promising alternative but cannot directly account for individual user preferences. We propose a framework integrating sim-to-real RL with online preference learning for personalized exoskeleton assistance. Specifically, assistance timing is learned in simulation by training RL policies with human musculoskeletal models across varying walking speeds. The learned policies are then distilled and deployed on a physical hip exoskeleton using onboard sensory observations. Gaussian-process-based preference learning further personalizes the assistance magnitude through pairwise user comparisons. By decoupling assistance timing learning in simulation from magnitude optimization in real-world experiments, our framework substantially reduces the online optimization space. Human-subject experiments demonstrate efficient identification of personalized assistive torque profiles across varying walking speeds with fewer real-world evaluations.

0.14

A Human-in-the-Loop Comparison of Proportional Control and Adaptive Gravity Compensation in Elbow EMG-Driven Exoskeletons

cs.RO ·2026-10-19 ·Francesco Pascucci, Eldison Dimo, Davide Costanzi, Mario Sedilesu, Andrea Calanca
similarity 0.61
Abstract · 8 pages, 10 figures, 4 tables

Electromyography (EMG)-driven control enables wearable robots to assist users based on their neuromuscular activity. Upper-limb exoskeletons typically rely on proportional myoelectric control (PMC), which amplifies user effort but may compromise stability at high assistance levels. EMG-driven adaptive gravity compensation (AGC) offers a promising alternative, counterbalancing gravitational torques while continuously adapting to neuromuscular activity. However, these approaches have not been systematically compared in a human-in-the-loop setting. This study evaluates five control algorithms: two PMC strategies at different assistance levels, a purely integral AGC (AGC-PI), a kinematics- and acceleration-aware model-based (MB) AGC (AGC-AW), and a novel MB AGC approach based on Recursive Least Squares (AGC-RLS) for online payload estimation. Fourteen healthy participants performed target-reaching tasks using an active elbow exoskeleton under 0 kg and 2 kg loading conditions. Performance metrics included muscular activity, movement accuracy, task efficiency, and subjective workload. PMC exhibited a trade-off between physical effort and task performance: low assistance levels required greater physical effort under load, whereas high gains impaired task execution. AGC-PI reduced agonist activity but induced antagonist activation. In contrast, both model-based AGC approaches effectively compensated for external payloads, reducing physical and cognitive demands while improving movement accuracy and completion time.

0.20

Design and Analysis of a Nonlinear Parallel Mechanism Coupling for Dynamic Humanoid Legs

cs.RO ·2026-10-12 ·Rohit Kumar, Heiner Peters, Felix Wiebe, Franek Stark, Janne Janzen +3 more
similarity 0.59
Abstract

Humanoids increasingly demand lightweight leg mechanisms for agile, dynamic, and energy-efficient locomotion. Reducing distal inertia through proximal actuation has thus become a common design goal. Yet, compact transmissions that preserve torque capability and efficient force transmission remain hard to achieve. This paper presents a novel series-parallel leg design combining a knee parallel mechanism, an ankle parallel mechanism, and a nonlinear knee-ankle coupling where all actuators placed closer to the hip. As the knee flexes, the coupling passively assists ankle dorsiflexion for foot clearance and, as it extends it assists plantarflexion for push-off, redistributing ankle load through the knee transmission. We derive the coupling's nonlinear transmission models and validate them in simulation and on hardware. The design shows that the shared transmission lets both joints draw on each other's actuator capacity by easing the knee's peak torque demand under load and the ankle's peak speed demand during fast motion. With the leg's proximal actuator placement, the leg achieves an effective reflected mass of 0.37 kg at the foot for a 6 kg leg, demonstrating very low distal leg inertia for dynamic humanoid robots.

0.12