CS Paper Radar

Assistance Torque Estimation via Dynamics-Aware Optimization for Lower-Limb Exoskeleton in Complex Environments

Xiao-Yin Liu, Guotao Li, Weiqun Wang, Zeng-Guang Hou

cs.RO ·submitted 2026-09-14 10:36 UTC · v1

Abstract

Ground-truth human joint torque estimation relies on motion capture systems, which suffer from limited outdoor usability and significant deployment expenses. Furthermore, direct scaling of ground-truth joint torques to obtain motor torque commands is not necessarily the optimal strategy. To address the aforementioned limitations, inspired by the human motion generation process, this paper proposes a novel assistance torque estimation method based on the dynamic model. From an optimization perspective, the proposed method directly generates motor-assist torque and lowers the cost of data acquisition. Then, a data-driven assistance torque prediction network is trained to enable accurate real-time prediction under complex outdoor environments. Experimental results demonstrate that optimized (estimated) assistance torque exhibits better phase consistency with gait trajectories and better alignment with task characteristics. Relative to the Zero torque condition, the predicted torque can decrease metabolic rate by 11.8%-17.7%, heart rate by 8.9%-14.3%, and peak muscle activation levels by 28.2%-54.0%, respectively. This provides a new perspective for low-cost adaptive exoskeleton assistance.

Comment
8 pages, 11 figures, https://youtu.be/CGxDD0jKpak

Closest papers

Nearest neighbours by meaning across the whole index.

General Performance Guarantee for Human Torque Estimation-Based Task-Agnostic Assistive Exoskeleton Control

cs.RO cs.LGeess.SY ·2026-09-30 ·Duy Hoang, Bastien Berret, Olivier Bruneau, Laurent Fribourg
theory similarity 0.75
Abstract · 10 pages, 8 figures

Accurate human torque estimation is crucial for enabling task-agnostic control in robotic exoskeleton systems. However, estimation errors may cause mismatches between the robot assistance and the human intention, degrading controllability and task performance. In this paper, we address this issue by formally defining matched assistance as scenarios in which the robot positively contributes to human movement. Based on this definition, we develop a theoretical framework to design the robot's desired interaction torque that guarantees a lower bound on the matched assistance probability. Importantly, the proposed guarantee holds over the entire torque distribution, including unseen data beyond the training tasks. This provides our method with strong reliability and generalization, both of which are critical for effective exoskeleton control. The proposed strategy is implemented on the ABLE upper-limb exoskeleton and evaluated in a multi-task setup. Experimental results validate the theoretical guarantees and demonstrate that the proposed strategy achieves effective general performance across several tasks, guaranteeing movement smoothness while reducing human physical effort.

0.19

ExoLaN: Physics-Consistent Context-Aware Dynamics Learning for Exoskeletons

cs.RO eess.SY ·2026-09-25 ·Lucas Schulze, Maximilian Schwarz, Jona Hoppe, Jan Peters, Oleg Arenz
similarity 0.70
Abstract

Task-agnostic assistive exoskeleton control based on human intention offers greater flexibility than conventional approaches that rely on predefined tasks or motion patterns. Human joint torque estimation enables task-agnostic assistance by characterizing user actions. Physics-consistent methods such as Deep Lagrangian Networks (DeLaN) have been applied to estimate the human torques in multi-user settings, but existing approaches cannot adapt to a specific user without retraining, and do not account for intermittent contacts during locomotion. We propose ExoLaN, a Context-Aware DeLaN for human-exoskeleton interaction that learns the full coupled system dynamics while adapting to changes in interaction context. ExoLaN combines temporal context with partial contact-force measurements from force-sensitive insoles to infer latent dynamics embeddings and estimate generalized contact torques. On seven unseen users performing 21 unseen tasks, ExoLaN reduces torque estimation MSE by 7% compared to a black-box baseline. Beyond inverse dynamics, ExoLaN serves as a unified model that also enables accurate forward prediction: training with a multi-step prediction loss reduces acceleration MSE by 59% and long-horizon position and velocity errors by 60% and 93%, respectively, compared with a single-step loss. Moreover, the learned latent context captures task information without explicit task labels, making it a promising signal for task-aware assistive control.

0.19

Learning human joint torques from pixels

cs.CV ·2026-08-10 ·Chen Chen, Rui Cheng
benchmarkdataset similarity 0.69
Abstract

Estimating human joint torques from visual observations is a key step toward bringing biomechanical analysis from controlled laboratories to real-world movement scenarios. Existing torque estimation methods typically depend on surface electromyography, motion-capture markers, force plates, or simulated imitation data, which limits their applicability to ordinary RGB images. In this work, we introduce VID, a vision-based inverse dynamics dataset and benchmark for predicting human joint torques directly from real monocular images. VID contains 63,369 synchronized frames with real human images, kinematic annotations, anthropometric attributes, and OpenSim-derived dynamic labels, providing paired visual and biomechanical supervision for real-image inverse dynamics. We further define a standardized evaluation protocol covering overall torque estimation, joint-specific analysis, and action-specific prediction. To establish a strong reference model, we propose VID-Network, which combines pose-pretrained spatial probabilistic features, marker regression, and temporal torque inference to recover joint torques from image sequences. Experiments on VID show that VID-Network achieves an overall mPJE of 1.7612 N$\cdot$m/kg, improving over the best compared baseline by 39.81\%, and obtains the lowest error across all evaluated joint types and most action categories. VID establishes a first practical benchmark for vision-driven human inverse dynamics and provides a foundation for studying biomechanical inference in less constrained environments.

0.04

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

cs.RO ·2026-10-30 ·Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang
code/data similarity 0.69
Abstract · 8 pages, 5 figures, 2 tables

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

0.22

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.67
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Learning a Speed-adaptive Hip Exoskeleton Control Policy Via Sim-to-real Reinforcement Learning

cs.RO ·2026-09-23 ·Bin Li, Zhimin Hou, Jiacheng Hou, Zenian Liang, Tong Wu +2 more
similarity 0.67
Abstract

Providing personalized exoskeleton assistance across varying walking speeds remains challenging. Existing online optimization methods are sample-inefficient, requiring extensive human-in-the-loop (HIL) evaluations to optimize the entire assistive torque profile. Sim-to-real reinforcement learning (RL) offers a promising alternative but cannot directly account for individual user preferences. We propose a framework integrating sim-to-real RL with online preference learning for personalized exoskeleton assistance. Specifically, assistance timing is learned in simulation by training RL policies with human musculoskeletal models across varying walking speeds. The learned policies are then distilled and deployed on a physical hip exoskeleton using onboard sensory observations. Gaussian-process-based preference learning further personalizes the assistance magnitude through pairwise user comparisons. By decoupling assistance timing learning in simulation from magnitude optimization in real-world experiments, our framework substantially reduces the online optimization space. Human-subject experiments demonstrate efficient identification of personalized assistive torque profiles across varying walking speeds with fewer real-world evaluations.

0.14

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

cs.RO ·2026-10-02 ·Neethan Ratnakumar, Mariya Tohfafarosh, Xianlian Zhou
similarity 0.67
Abstract

Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.

0.14

Personalized Lower-limb Exoskeleton Assistance via Preference-based Bayesian Optimization

cs.RO ·2026-08-10 ·Xiao-Yin Liu, Guotao Li, Weiqun Wang, Zeng-Guang Hou
similarity 0.66
Abstract · 20 pages, 15 figures, https://youtu.be/8X1SFqUU4G4

A significant challenge in exoskeleton robotics is the need to dynamically adapt control profiles to individual motion preferences, thereby ensuring both efficient and comfortable assistance. Currently, since user experience can serve as a comprehensive metric for evaluating the effectiveness of assistance, user preference-based optimization methods have been widely studied for parameter tuning. However, the existing methods rely heavily on extensive human-robot online interactions and suffer from slow optimization speed, which not only induces user fatigue but also compromises optimization effectiveness. Therefore, this paper aims to explore an efficient preference-based optimization framework for personalized exoskeleton assistance that can learn optimal parameters with minimal interaction. We propose a preference-based Bayesian optimization (PbBO) approach that can improve sample efficiency by leveraging knowledge about the sampling distribution of candidate sets. For optimizing six control parameters, PbBO can converge to user-preferred parameters with 90.7% validation accuracy via 20 iterations. Moreover, the hierarchical controller is designed to generate personalized torque for different tasks and achieve interaction torque tracking in real time. The results of treadmill and outdoor experiments demonstrate that the optimized parameters can reduce metabolic rate by 14.5%-15.4%, heart rate by 6.3%-7.6%, and muscle activation by 6.7%-31.5% compared to unassisted walking.

0.56