CS Paper Radar

A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft Exosuits

Anoush Sepehri, Zachary Huang, Raymond de Callafon, Michael T. Tolley, Tania K. Morimoto

cs.RO cs.HC ·submitted 2026-08-18 22:30 UTC · v1

Abstract

Pneumatic artificial muscles have provided new opportunities to develop upper-extremity soft exosuits for reha- bilitation, augmentation, and assisted daily living. However, the complex dynamics and limited bandwidth of these actuators has made providing responsive assistance based on user intention a longstanding challenge. In this work, we present an inverse-plant control strategy for pneumatically actuated soft exosuits that only relies on kinematic sensing for task-agnostic and dynamic assistance during daily living. We model the human-robot system using a Hammerstein dynamic model, consisting of a Preisach hysteresis model and a linear time-invariant filter, to capture the static and dynamic behavior of the system. We personalize our model to each user using 140 s of data and approximate an inverse to integrate into our control loop. When evaluated on a test rig that emulated a soft assistive exosuit for the wrist, our controller reduced the interaction torque by up to 73% and the activation of key flexor and extensor muscles by up to 47% relative to the condition with no assistance for speeds ranging from 8°/s to 120°/s. Overall, this work presents a control strategy that can provide task-agnostic, dynamic assistance with pneumatically actuated soft exosuits without the need for physiological or force sensors to interpret user intention.

Closest papers

Nearest neighbours by meaning across the whole index.

Task-space model-based control of pneumatic soft actuators

cs.RO ·2026-08-27 ·Nithin S. Kumar, Joshua Gaston, D. Caleb Rucker, Eric J. Barth
top venue similarity 0.70
Abstract · 11 pages, 14 figures

Soft actuators enable dexterous and compliant interaction, but closed-loop task-space control remains challenging due to strong nonlinearities, distributed deformation, and uncertainty in their dynamics. This paper presents a real-time dynamic-model-based task-space feedback and estimation framework based on a non-minimal coordinate discrete elastic rod model formulated in absolute coordinates with holonomic constraints. The resulting structure preserves distributed mechanics while maintaining computational efficiency through sparse system matrices, enabling real-time control with up to 10 discretized rods. A quasi-static feedforward inverse model is combined with a task-space PI controller and a dynamic observer that fuses measurement residuals as virtual forces, enabling full-state estimation from sparse sensing. The approach is experimentally validated on three planar pneumatic soft actuators with varying geometries. Across five tasks, including drawing the digits 0-9 across the workspace (3-18 mm/s tip speed), tracking periodic motion (up to 37 cm/s), cross-platform generalization, reduced sensing conditions, and real-time user-defined references, our method achieves 1.5-2.3 mm root mean square error (RMSE) for precision motions and 5.5-12.4 mm RMSE at 1-2 Hz. Results demonstrate that structured, non-minimal dynamic models can enable real-time, high-precision, moderate-bandwidth task-space control of planar soft pneumatic actuators in free space.

0.27

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.66
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24

Recursive Self-Improvement of Exoskeleton Assistance Policies through Human-in-the-Loop Feedback

cs.RO ·2026-11-01 ·Muyuan Ma, Shuo Jiang, Lijun Han, Xinpan Meng, Zhenghua Ma +3 more
hot direction similarity 0.64
Abstract

To reduce reliance on manual design and extensive parameter tuning, a framework for the autonomous evolution of exoskeleton assistance policies through human feedback is proposed. Assistance policies are autonomously generated as executable control code by an intelligent agent and evaluated in experiments with human participants. Subjective user feedback, movement performance, and muscle activation measurements are incorporated into policy assessment. Based on these assessments, policy deficiencies are autonomously identified and the control code is revised by the agent for subsequent trials. A closed loop of policy generation, human feedback, evaluation, and autonomous refinement is thereby established. The framework is evaluated using GPT, DeepSeek, GLM, and Kimi, and initial assistance performance and refinement outcomes are compared across models. Despite differences in initial performance, effective assistance is achieved with all four models after a single autonomous refinement iteration under the tested conditions. Across three tasks, biceps and triceps muscle activation levels are reduced by 29.4% and 35.2%, respectively, compared with those measured without an exoskeleton. However, limited adaptability to unexpected situations is observed, indicating that further improvements in robustness and safety are required.

0.30

General Performance Guarantee for Human Torque Estimation-Based Task-Agnostic Assistive Exoskeleton Control

cs.RO cs.LGeess.SY ·2026-09-30 ·Duy Hoang, Bastien Berret, Olivier Bruneau, Laurent Fribourg
theory similarity 0.64
Abstract · 10 pages, 8 figures

Accurate human torque estimation is crucial for enabling task-agnostic control in robotic exoskeleton systems. However, estimation errors may cause mismatches between the robot assistance and the human intention, degrading controllability and task performance. In this paper, we address this issue by formally defining matched assistance as scenarios in which the robot positively contributes to human movement. Based on this definition, we develop a theoretical framework to design the robot's desired interaction torque that guarantees a lower bound on the matched assistance probability. Importantly, the proposed guarantee holds over the entire torque distribution, including unseen data beyond the training tasks. This provides our method with strong reliability and generalization, both of which are critical for effective exoskeleton control. The proposed strategy is implemented on the ABLE upper-limb exoskeleton and evaluated in a multi-task setup. Experimental results validate the theoretical guarantees and demonstrate that the proposed strategy achieves effective general performance across several tasks, guaranteeing movement smoothness while reducing human physical effort.

0.19

Enabling Scalable Kinesthetic Teaching via Observer-based Hand-guiding with Active Support

cs.RO ·2026-08-11 ·Anna Tuma, Giuseppe Monetti, Jochen J. Steil, Niels Dehio
published similarity 0.63
Abstract

Kinesthetic teaching through robot hand-guiding provides a natural interface for collecting demonstrations in imitation learning and programming-by-demonstration. However, extended sessions cause operator fatigue, reducing demonstration quality and limiting scalability. Current industrial hand-guiding approaches typically provide no active assistance, and alternatives require costly wrist-mounted force-torque sensors or rely on learned motion priors unavailable for new tasks. We propose RHOAS, a hand-guiding scheme that actively supports operator-intended motions using model-based force estimation without additional hardware. Our approach considers robot hand-guiding as an actively controlled interaction by the human operator, rather than an interaction with a passive environment. Standard methods used for hand-guiding typically rely on general passivity-based compliant control architectures that unnecessarily increase operator effort and limit the range of demonstrable motions without providing the intended stability guarantees in active interaction. Instead, our design utilizes model-based external torque estimation, internal joint torque sensing, and redundant robot kinematics to actively support human physical input within the human interaction frequency bandwidth. We address practical challenges of relying on observer-based force estimation, including suppression of unmodeled joint elastic dynamic effects and measurement noise in the feedback path, reduced estimate accuracy close to kinematic singularities, and static gravity compensation errors. In a user study with 16 participants on a KUKA LWR iiwa we demonstrate statistically significant reductions in physical effort, improved maneuverability for both precise and agile tasks, and clear user preference.

0.23

Assistance Torque Estimation via Dynamics-Aware Optimization for Lower-Limb Exoskeleton in Complex Environments

cs.RO ·2026-09-14 ·Xiao-Yin Liu, Guotao Li, Weiqun Wang, Zeng-Guang Hou
similarity 0.63
Abstract · 8 pages, 11 figures, https://youtu.be/CGxDD0jKpak

Ground-truth human joint torque estimation relies on motion capture systems, which suffer from limited outdoor usability and significant deployment expenses. Furthermore, direct scaling of ground-truth joint torques to obtain motor torque commands is not necessarily the optimal strategy. To address the aforementioned limitations, inspired by the human motion generation process, this paper proposes a novel assistance torque estimation method based on the dynamic model. From an optimization perspective, the proposed method directly generates motor-assist torque and lowers the cost of data acquisition. Then, a data-driven assistance torque prediction network is trained to enable accurate real-time prediction under complex outdoor environments. Experimental results demonstrate that optimized (estimated) assistance torque exhibits better phase consistency with gait trajectories and better alignment with task characteristics. Relative to the Zero torque condition, the predicted torque can decrease metabolic rate by 11.8%-17.7%, heart rate by 8.9%-14.3%, and peak muscle activation levels by 28.2%-54.0%, respectively. This provides a new perspective for low-cost adaptive exoskeleton assistance.

0.21

Whole-Body Motion Guided Reference Generation for Uncertainty-Aware Compliant Assistance

cs.RO ·2026-10-22 ·Muyuan Ma, Long Cheng, Lijun Han, Haotian Zhai, Xinpan Meng +3 more
similarity 0.62
Abstract · Withdrawal requested because not all co-authors had consented to the submission of this manuscript to arXiv

Exoskeletons have shown great potential for augmenting human physical capabilities, yet generating reliable assistance remains challenging because human motion patterns and interaction requirements vary substantially in practice. To address this problem, a dual-loop assistance strategy is proposed to couple multimodal exoskeleton trajectory generation with variable admittance control, where trajectory variance links the outer-loop generator and the inner-loop controller. The generator synthesizes future exoskeleton trajectories through denoising, primarily using whole-body human motion and exoskeleton proprioception, with task descriptions as auxiliary semantic cues. To reduce cross-modal representation mismatch, a three-stage training pipeline is introduced to progressively optimize the human motion encoder, the exoskeleton proprioception encoder, and the trajectory generator. In the inner loop, multiple future trajectories are sampled from the generator to estimate the trajectory mean and variance. The mean is used as the control reference, while the variance provides an uncertainty measure for prediction reliability. This measure is further incorporated into a stiffness regulation law, enabling compliant assistance with input-to-state stability under bounded lumped interaction input. Experimental results demonstrate that the proposed method significantly reduces muscle activation levels compared with standard baselines, while also decreasing users' metabolic energy expenditure relative to the unassisted condition.

0.21

GIFT: Glove-Inferred Force Transfer: Force-Aware Human-to-Robot Skill Transfer from a Wearable Sensing Glove to a Robot Hand Without Tactile Sensors

cs.RO ·2026-09-12 ·Tzach Sarusi
code/data similarity 0.62
Abstract · 7 pages, 5 figures, 1 table. Project page: https://tzahsarusi.github.io

Human-to-robot skill transfer from sensing gloves has so far relied on shared hardware: the same tactile glove worn by the demonstrator and the robot, or a learned alignment between two tactile sensors. We present GIFT (Glove-Inferred Force Transfer), a pipeline in which the interface between human and robot is a physical unit rather than a shared sensor: fingertip force is measured in newtons on the human side and estimated in newtons on the robot side. A wearable glove records finger flexion, calibrated fingertip force, and wrist orientation, while a head-mounted camera records the demonstration; no robot is present. At deployment, the robot estimates force from actuator-current residuals relative to a free-space baseline, through a calibrated mapping to newtons, so any position-controlled hand that reports motor current can serve as the deployment platform. The policy uses a glove-space state and predicts finger-position targets; the robot enters only through two calibrated adapters, a retargeting decoder and a force estimator. We evaluate GIFT on a cup grasp-and-hold task with two action-chunking policies trained on the same demonstrations, with fingertip-force inputs retained in one and zeroed in the other. In a 50-rollout evaluation with sample size and metrics fixed before scoring, both policies succeeded in all 25 rollouts. The median of the per-rollout hold-phase grip-force estimates was 53% lower with force inputs: 1.20 N versus 2.55 N (one-sided Mann-Whitney U, p<0.0001). In an observation ablation, a vision-only policy achieved 0/15 grasps, policies given hand-command state acquired the grasp, and the force inputs determined how hard the policy held. A force channel measured on the human hand thus transfers to a robot hand with no tactile hardware, through a retargeting map from five glove channels to seven robot actuators, with no sensor shared between the two.

0.32