CS Paper Radar

Daily listing

2026-09-15 · cs.MS

2 papers first submitted this day (UTC) in cs.MS — Mathematical Software. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Software & Programming 1

Flash-Radiomics: A Scalable Hybrid CPU-CUDA Engine for Standardized Scalar Radiomics and Accelerated Spatial Mapping

cs.MS q-bio.OTeess.IVphysics.med-ph ·2026-09-15 ·Shanli Ding, Yiyi Hu, Ziyu Fu, Chia-Hsin Lin, Ruihan Luo +3 more
Abstract · 20 pages, 5 figures

Background and Objectives: Spatial mapping retains the spatial distribution of radiomic features, but computational cost and fragmented software limit its use. We developed Flash-Radiomics with scalar extraction and spatial mapping, a central processing unit (CPU) backend, a hybrid Compute Unified Device Architecture (CUDA) backend, consistent feature names, and Hierarchical Data Format version 5 (HDF5) storage. Methods: We evaluated Image Biomarker Standardisation Initiative (IBSI) compliance, CPU-CUDA concordance, and end-to-end processing time. Compliance testing included 825 chapter 1 (IBSI-1) tests covering 165 high-consensus features and 323 chapter 2 (IBSI-2) tests with numerical references. Concordance testing included 1,148 scalar pairs and 93 spatial-map pairs. End-to-end processing time was measured five times per input volume of interest (VOI) size. Comparisons included the Medical Image Radiomics Processor (MIRP) and PyRadiomics for 102 shared scalar features and PyRadiomics for 93 shared spatial maps. Results: Both backends passed all 1,148 IBSI tests, and all paired results were concordant. At the largest scalar input, CPU required 76.343 s and hybrid CUDA 81.915 s; CPU was 4.7 times faster than MIRP and 190.7 times faster than PyRadiomics. At the largest spatial input completed by both backends, hybrid CUDA reduced processing time by 68.6% relative to CPU (79.280 versus 252.791 s). At PyRadiomics' largest completed spatial input, hybrid CUDA was 84.9 times faster. Conclusions: Flash-Radiomics unified standardized scalar extraction, spatial mapping, concordant CPU-CUDA results, and HDF5 storage. CPU processing time was similar or shorter for scalar extraction, whereas hybrid CUDA was faster for spatial mapping under the tested conditions.

0.31

Robotics, Control & Signals 1

ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals

eess.SP cs.CLcs.MS ·2026-09-15 ·Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
Abstract · Under Review

Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation.

0.17