CS Paper Radar

Daily listing

2026-09-16 · eess.IV

9 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 9

Semantic-Guided Fusion Network for Multi-Source Remote Sensing Image Classification

eess.IV cs.CV ·2026-09-16 ·Yuwei Zhao, Chuanzheng Gong, Baogui Huan, Feng Gao, Junyu Dong +1 more
publishedcode/data
Abstract · Accepted for publication in IEEE GRSL 2026

Multi-source remote sensing image classification has attracted increasing attention due to the complementary spectral, structural, and geometric information. However, existing methods still suffer from two limitations: insufficient semantic contextual modeling and unreliable feature fusion caused by slight spatial misalignment. To address these issues, we propose a Semantic-Guided Fusion Network (SGFNet) for multi-source remote sensing image classification. Specifically, the Semantic Mixing Convolution Block (SMCB) is designed to dynamically generate semantic-aware convolution kernels according to contextual relationships among feature representations. In addition, the Frequency Modulated Fusion Block (FMFB) is introduced to perform cross-modal interaction in the frequency domain, which effectively alleviates the influence of slight spatial misalignment and improves complementary information fusion. Extensive experiments conducted on the Augsburg and Houston 2018 datasets demonstrate that the proposed SGFNet consistently outperforms several state-of-the-art methods. The codes are publicly available at https://github.com/oucailab/SGFNet .

0.58

NIMARC-MRI: Abdominal HASTE Dataset and a Baseline U-Net Exposing the Synthetic-to-Real Gap in Low-Resource Motion Correction

eess.IV ·2026-09-16 ·Abdulrazaq A. Zubair, Nafiu Musa Muhammad, Simeon Krah, Ummasalma Usman Ibrahim, Yusuf Tijjani Abdumumin +5 more
publishedunusual
Abstract · Accepted for publication at the MIRASOL Workshop at MICCAI 2026

Respiratory motion degrades abdominal T2 HASTE MRI in low- and middle-income countries where vendor motion-correction licenses are unavailable and failed scans are deleted during routine PACS cleanup, precluding supervised training. To address this, we introduce NIMARC-MRI, the first public abdominal MRI dataset from West Africa, comprising 139 clean HASTE, 25 native motion-degraded HASTE, and 79 paired HASTE-TSE TRIGGER acquisitions from a Nigerian centre operating 1.5 T Siemens scanner without integrated motion-correction licenses. A 2D U-Net with 7.7 million parameters was trained on 3D-consistent synthetic respiratory motion necessitated by local infrastructure reality and validated via a three-tier strategy: held-out synthetic data, blinded radiologist Likert scoring on native real motion, and cross-sequence TRIGGER generalisation. On synthetic test data the model achieved SSIM 0.863 +/- 0.042 and PSNR 30.06 +/- 1.80 dB. On native real motion, however, blinded radiologist and radiographer scores showed no significant improvement (mean Likert 4.06 +/- 0.55 original versus 4.04 +/- 0.61 corrected, P = 0.914), with 28% of cases rated worse after correction. Cross-sequence TRIGGER evaluation showed modest SSIM improvement (0.404 +/- 0.073 versus 0.334 +/- 0.055, P < 0.001) without radiologist-perceived gain. These findings demonstrate that conservative synthetic motion fails to capture clinical motion severity, exposing a reproducible synthetic-to-real gap. NIMARC-MRI is released on Zenodo (https://doi.org) under a controlled data-use agreement requiring citation. Sequence metadata and a sample subset are publicly accessible to facilitate discovery, while patient-level data remain restricted to approved collaborators. The aim is to establish a reproducible baseline for motion correction in resource-constrained settings.

0.45

Visual Autoregressive Priors for RAW-to-sRGB Image Signal Processing

cs.CV cs.MMeess.IV ·2026-09-16 ·Tailai Chen, Xiaotong Luo, Yuan Gao, Xin Jin, Wenjun Zeng
publishedbenchmark
Abstract · Accepted at ECCV 2026 Workshop on Low-Level Vision Frontiers (LoViF). 13 pages, 4 figures

RAW-to-sRGB image signal processing (ISP) must recover perceptually faithful colors and fine details from sensor measurements, often under imperfect spatial alignment and missing camera metadata. This paper presents, to the best of our knowledge, the first application of visual autoregressive (VAR) next-scale prediction over a discrete image codebook to the RAW-to-sRGB ISP task. We adapt a frozen 1.10\,B-parameter VAR backbone for RAW-conditioned ISP with only 32.93\,M trainable parameters (2.99\%), and propose a frequency-decomposed color loss that separately supervises low-frequency tone via wavelet LL cosine similarity and chromatic edges via detail-band $\ell_1$. On the Zurich RAW-to-sRGB benchmark, the method improves PSNR-Y from 21.31 to 21.89\,dB and reduces LPIPS from 0.276 to 0.218 on the full 1,204-image test set. Diagnostic experiments show that the VAR prior preserves structure well, but continuous color transfer remains the dominant bottleneck: oracle affine correction recovers 3.8\,dB, while learned color heads yield marginal gains.

0.44

Highly accelerated 3D Cartesian MPnRAGE with implicit neural representation reconstruction

eess.IV ·2026-09-16 ·Natascha Niessen, Ana Beatriz Solana, Carolin M. Pirkl, Tim Sprenger, Hannah Eichhorn +7 more
hot direction
Abstract

MPnRAGE enables multiple inversion contrast images in a single scan, allowing quantitative T1 mapping, tissue nulled contrasts, and standard MPRAGE synthesis. However, current 3D scan times remain clinically impractical, motivating accelerated 3D MPnRAGE. This work provides a highly accelerated Cartesian 3D MPnRAGE sequence with joint implicit neural representation (INR) reconstruction. The sequence uses a tailored view-ordering strategy, flip angle schedule and complementary variable-density Poisson-disk undersampling. Calibration data acquired during otherwise unused delay time are used for sensitivity map estimation and complementary high-frequency sampling. Ten INR-reconstructed inversion images at 1.5 mm$^3$ are evaluated against fully sampled references via retrospective undersampling. Prospectively accelerated 1 mm$^3$ images at R = 20 (5.39 min) demonstrate clinical feasibility. INR reconstruction outperforms subspace and iterative local low rank reconstruction on highly accelerated data. The proposed highly undersampled 3D Cartesian MPnRAGE with INR reconstruction generates multiple high-quality inversion contrasts in substantially reduced scan time. Scan-specific INR reconstruction improves image quality while reducing reconstruction time versus state-of-the-art methods.

0.39

Perceptual Refinement of an End-to-End Video Streaming Pipeline via Generative AI Layers

eess.IV cs.AIcs.CVcs.MM ·2026-09-16 ·Emanuele Artioli, Farzad Tashtarian, Christian Timmerer
theorycode/data
Abstract · 28 pages. Submitted to ACM Transactions on Multimedia Computing, Communications and Applications (TOMM), special issue on MMSys and co-locat…

Traditional codecs treat every region of a frame alike; a generative layer can instead degrade the regions a viewer attends to least and reconstruct them at the client. We present PRESLEY, which extends the prior conference work ELVIS by replacing destructive block removal with adaptive in-place degradation under a removability mask, signaling per-block strength in a bit-packed side channel, and restoring via generative backbones conditioned on transmitted visual priors rather than unconditioned in-painting. We separate the problem into three goals: choosing which blocks to degrade, degrading them so the encoder spends fewer bits, and restoring them. Against its predecessor at matched rate, PRESLEY achieves a decisive mean -56.4% BD-rate reduction on delivered background quality across 13 rate ladders spanning multiple codecs and dataset families. Against pristine baselines, PRESLEY defines the operating regime of generative transport: delivering substantial bitrate savings (up to -29.4% BD-rate) and superior background quality (17/23 sequences) in the target bit-starved regime, while maintaining foreground fidelity bit-exact. We further map where the theoretical headroom in this class of architecture lies. Using an exact leave-one-superblock-out combinatorial oracle as an additive empirical bound, we show that existing complexity heuristics already capture 83.3% of bit-cost savings, bounding remaining cost-axis headroom at about 5% of total bitrate. We then identify and model the primary unaddressed axis -- post-restoration damage -- which disperses widely (4.9-8.4 dB). We prove that this damage is predictable before transmission (held-out rho = +0.400), establishing the feasibility of transmit-time restorability modeling and defining the roadmap for joint rate-distortion-restoration selection rules.

0.38

Constrained Color Carrier: Characterization-Preserving Conditional Color Rendering in Multi-Illuminant Camera Profiles

eess.IV ·2026-09-16 ·Xilai Liang
Abstract · 21pages, 3 figures

In Digital Negative (DNG) multi-illuminant profiles, characterization matrices and nonlinear rendering payloads share condition-dependent interpolation slots, so adding a slot for rendering capacity also introduces an additional characterization state. We introduce Constrained Color Carrier (CCC), which constructs the three pre-serialization ColorMatrix and ForwardMatrix states from the original dual matrix segments while allowing the same shared slots to carry three HueSatMap rendering bases. Condition-specific HueSatMap payloads are solved as numerical preimages of the target through a fixed serialized downstream rendering operator, and carrier selection enforces a preservation bound on the host-effective interpolated characterization. We evaluate CCC on the Sony ILCE-7RM5 Adobe Standard dual-illuminant profile using a white-balance-dependent Standard ColorCorrect target recovered from Phocus 4.0.1 for the Hasselblad X2D 100C. Using Euclidean Oklab error, CCC yields a worst-temperature 95th-percentile preservation error of 0.003857, below the prescribed tolerance of 0.004, and reduces the worst-condition 95th-percentile target error from 0.08208 for the Dual representation to 0.03508. The synthetic Ordinary Triple yields a preservation error of 0.014802 and exceeds the same tolerance. The serialized DNG Camera Profile (DCP) and Extensible Metadata Platform (XMP) artifacts reproduce the final color-table payloads exactly and yield zero numerical difference from solver-side offline execution, showing that the CCC solution is representable within the evaluated serialized profile format.

0.37

Mammography Foundation Models for Opportunistic Prediction of Major Adverse Cardiovascular Events

eess.IV cs.CVcs.LG ·2026-09-16 ·Paula Feldman, Nusrat Binta Nizam, Sunwoo Kwak, Batuhan Karaman, Katerina Dodelzon +1 more
code/data
Abstract

Cardiovascular disease (CVD) remains the leading cause of death among women, yet cardiovascular risk assessment often relies on clinical variables that may be missing, outdated, or unavailable in routine care. Screening mammography offers an opportunity for opportunistic cardiovascular risk stratification because it is routinely acquired and contains vascular features, including breast arterial calcifications (BAC), that are associated with cardiovascular risk and events. We evaluate whether mammography specific foundation models, originally pretrained for breast cancer-related tasks, can transfer to cardiovascular risk prediction without cardiovascular specific supervision or explicit BAC annotation. We constructed a 5-year major adverse cardiovascular event (MACE) cohort of 22,497 women linked to electronic health record outcomes, including 500 events (2.22% prevalence). The foundation models achieved AUROCs of 0.823 and 0.822 substantially exceeding an age-only model (AUROC 0.765), despite using only the screening mammogram as input, with no clinical variables. Both foundation models evaluated assigned substantially higher predicted risk to patients with radiologist-documented BAC, despite BAC never being used as a training label, and showed activation patterns consistent with vascular findings. Together, these findings suggest that mammography foundation models can recover clinically relevant cardiovascular risk information directly from mammographic pixels and suggest that screening mammography may provide an opportunistic source of cardiovascular risk information to complement conventional clinical assessment without additional imaging. Code is available in https://github.com/PauFeld/MammoCVD

0.36

Informed Sinogram Interpolation for Sparse View Reconstruction

eess.IV ·2026-09-16 ·Yuejie Liu, Alessandro Lupoli, David Uribe Gallo, Andreas Fischer, Felix Krahmer
Abstract

Computed tomography (CT) has been widely used in medical examinations and non-destructive testing. Micro-CT (microfocus X-ray CT system) is an advanced version that can observe the internal structures of small objects. However, secondary radiation can prevent micro-CT from imaging the full structure of the object. Given the same amount of secondary scans as primary scans, simple subtraction solves the problem at the price of doubled acquisition time. To reduce the acquisition time, one aims to limit the secondary scans to as few imaging angles as possible and interpolate to recover the missing data. Different interpolation methods have been explored for limited-angle tomography, such as polynomial or spline interpolation, compressive sensing, deep learning, etc. In contrast to many of these scenarios, the secondary imaging setup considered in this paper often exhibits simple sinusoidal structures that are not exploited directly by any of the aforementioned approaches. This paper aims to fill this gap with a continuous mathematical model describing the secondary sinogram only with information from the projection space. Building on this model, we propose an interpolation method that effectively interpolates secondary scans from limited observations.

0.27

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11