CS Paper Radar

NIMARC-MRI: Abdominal HASTE Dataset and a Baseline U-Net Exposing the Synthetic-to-Real Gap in Low-Resource Motion Correction

Abdulrazaq A. Zubair, Nafiu Musa Muhammad, Simeon Krah, Ummasalma Usman Ibrahim, Yusuf Tijjani Abdumumin, Ismail Ismail Tijjani, Ummulkhairi Ibrahim, Alyasaa Anas, Mubaraq Yakubu, Abbas Rabiu Muhammad

eess.IV ·submitted 2026-09-16 18:43 UTC · v1
publishedunusual

Abstract

Respiratory motion degrades abdominal T2 HASTE MRI in low- and middle-income countries where vendor motion-correction licenses are unavailable and failed scans are deleted during routine PACS cleanup, precluding supervised training. To address this, we introduce NIMARC-MRI, the first public abdominal MRI dataset from West Africa, comprising 139 clean HASTE, 25 native motion-degraded HASTE, and 79 paired HASTE-TSE TRIGGER acquisitions from a Nigerian centre operating 1.5 T Siemens scanner without integrated motion-correction licenses. A 2D U-Net with 7.7 million parameters was trained on 3D-consistent synthetic respiratory motion necessitated by local infrastructure reality and validated via a three-tier strategy: held-out synthetic data, blinded radiologist Likert scoring on native real motion, and cross-sequence TRIGGER generalisation. On synthetic test data the model achieved SSIM 0.863 +/- 0.042 and PSNR 30.06 +/- 1.80 dB. On native real motion, however, blinded radiologist and radiographer scores showed no significant improvement (mean Likert 4.06 +/- 0.55 original versus 4.04 +/- 0.61 corrected, P = 0.914), with 28% of cases rated worse after correction. Cross-sequence TRIGGER evaluation showed modest SSIM improvement (0.404 +/- 0.073 versus 0.334 +/- 0.055, P < 0.001) without radiologist-perceived gain. These findings demonstrate that conservative synthetic motion fails to capture clinical motion severity, exposing a reproducible synthetic-to-real gap. NIMARC-MRI is released on Zenodo (https://doi.org) under a controlled data-use agreement requiring citation. Sequence metadata and a sample subset are publicly accessible to facilitate discovery, while patient-level data remain restricted to approved collaborators. The aim is to establish a reproducible baseline for motion correction in resource-constrained settings.

Comment
Accepted for publication at the MIRASOL Workshop at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Fast Slice-Wise Deep Learning Motion Correction for Spinal Cord Functional MRI

cs.CV ·2026-11-10 ·Thomas Dagonneau, Sandrine Bédard, Nontharat Tucksinapinunchai, Uten Yarach, Loïc Le Folgoc +2 more
code/data similarity 0.59
Abstract · 4 pages, 3 figures

Respiratory and bulk motion displace the spinal cord between the volumes of a functional MRI time series. Current methods such as the Spinal Cord Toolbox (SCT) take several minutes per time series, and general-purpose brain tools register whole volumes, whereas the cord moves mainly slice by slice. We propose a lightweight convolutional neural network that regresses the in-plane translation aligning each axial slice to a reference. Two models, trained without motion labels, correct large and then residual motion. On a 3T (120 scans) and a 7T (59 scans) dataset, the proposed method improves on SCT on every metric (tSNR +10 to +25%, DVARS -20 to -38%), leaves almost no slice displaced by more than one voxel (<0.1%), performs on par with a slice-wise AFNI variant and better than slice-wise FSL FLIRT, and runs in about 10 s per scan, about 30 times faster than SCT. The code is available at https://github.com/ivadomed/moco-dl and the method is available in SCT v7.4.

0.38

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

cs.CV physics.med-ph ·2026-11-01 ·Mojtaba Safari, Parag J. Parikh, Shansong Wang, Mingzhe Hu, Philip Connell +4 more
similarity 0.57
Abstract

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

0.21

DoReMe: Dual optimization of Reconstruction and Motion estimation for self-navigated free-breathing abdominal MRI using Gaussian Splatting

eess.IV cs.CVphysics.med-ph ·2026-10-13 ·Majd Helo, Dominik Nickel, Thomas Kuestner
similarity 0.55
Abstract · 25 pages, 2 tables and 7 figures

Purpose: Free-breathing abdominal MRI is limited by respiratory motion, which introduces image artifacts and k-space inconsistencies. Existing reconstruction approaches often depend on pre-estimated motion fields or external respiratory surrogate signals. We propose a coupled reconstruction-motion estimation algorithm for self-navigated free-breathing acquisition, in which motion is represented by compact Gaussian primitives and jointly refined with the image estimates during iterative reconstruction. Methods: An iterative reconstruction that alternates between data consistency updates and motion modelling was proposed. Respiratory motion was represented using Gaussian primitives. A Gaussian splatting was integrated into the reconstruction algorithm. The method was evaluated on self-navigated free-breathing Cartesian gradient-echo (GRE) acquisition in four healthy volunteers, including retrospective scan shortening experiments, and was compared with regularized compressed sensing (CS) reconstruction. Results: Respiratory motion states were reconstructed in approximately 1.5 min. Compared with CS, the proposed method improved visual image quality, particularly in coronal liver views, and better preserved anatomical structures in retrospectively shortened acquisitions. These findings provide proof of concept for the proposed method. Conclusion: The proposed coupled reconstruction-motion estimation algorithm improved visual image quality compared with CS alone. Gaussian primitives provided a compact and sufficiently flexible representation of nonrigid respiratory motion with practical runtime, supporting further scanner integration and validation in larger cohorts.

0.22

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.55
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.22

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

cs.CV physics.med-ph ·2026-08-10 ·Mojtaba Safari, Shansong Wang, Zach Eidex, Matthew Goette, Tonghe Wang +2 more
top venue similarity 0.54
Abstract

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

0.29

Trading Parameters for Accuracy in MambaVision for Chest Radiograph Classification

cs.CV ·2026-11-15 ·Qaiser Farooq, Tehseen Zia
similarity 0.54
Abstract · 10 pages, 4 figures, 9 tables. Submitted to an IEEE journal

MambaVision, a hybrid state-space and attention backbone, places most of its parameters in its widest, fourth stage. We quantified what that stage contributes to multi-label chest radiograph classification. The fourth stage was replaced with lighter single-scan state-space blocks adapted from Spatial-Mamba, with multi-scale dilated depthwise convolutions applied to the scan output; the first three stages were retained. Tiny, Small, and Base models were evaluated across nine dataset-scale combinations drawn from two source cohorts: the National Institutes of Health ChestX-ray14 archive (full ChestMNIST and a high-resolution subset) and Indiana University Open-i. At the Tiny scale, replacement reduced parameter count by 35.7% and increased graphics processing unit throughput by 19.3%; the savings came from the stage's dense projections, not from removing quadratic attention. Without distillation, the mean area under the receiver operating characteristic curve on ChestMNIST was 0.004 lower than the baseline (95% bootstrap confidence interval, 0.002 to 0.006), and 0.003 to 0.006 lower across all nine combinations. Knowledge distillation from an unreplaced teacher narrowed the gap to the undistilled baseline to 0.001-0.002 and met the equivalence criterion on ChestMNIST, but distilling the baseline with the same recipe improved it by 0.001-0.003, so a gap of 0.002-0.005 persisted under symmetric training. At the Base scale, the unreplaced Small model was both smaller and more accurate. Fourth-stage replacement is a useful trade-off only for Tiny and Small models. These measurements let developers of chest radiograph screening tools weigh model size and speed against a quantified loss of diagnostic discrimination.

0.30

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.53
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.17

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.52
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.26