CS Paper Radar

Trading Parameters for Accuracy in MambaVision for Chest Radiograph Classification

Qaiser Farooq, Tehseen Zia

cs.CV ·submitted 2026-11-15 16:24 UTC · v1

Abstract

MambaVision, a hybrid state-space and attention backbone, places most of its parameters in its widest, fourth stage. We quantified what that stage contributes to multi-label chest radiograph classification. The fourth stage was replaced with lighter single-scan state-space blocks adapted from Spatial-Mamba, with multi-scale dilated depthwise convolutions applied to the scan output; the first three stages were retained. Tiny, Small, and Base models were evaluated across nine dataset-scale combinations drawn from two source cohorts: the National Institutes of Health ChestX-ray14 archive (full ChestMNIST and a high-resolution subset) and Indiana University Open-i. At the Tiny scale, replacement reduced parameter count by 35.7% and increased graphics processing unit throughput by 19.3%; the savings came from the stage's dense projections, not from removing quadratic attention. Without distillation, the mean area under the receiver operating characteristic curve on ChestMNIST was 0.004 lower than the baseline (95% bootstrap confidence interval, 0.002 to 0.006), and 0.003 to 0.006 lower across all nine combinations. Knowledge distillation from an unreplaced teacher narrowed the gap to the undistilled baseline to 0.001-0.002 and met the equivalence criterion on ChestMNIST, but distilling the baseline with the same recipe improved it by 0.001-0.003, so a gap of 0.002-0.005 persisted under symmetric training. At the Base scale, the unreplaced Small model was both smaller and more accurate. Fourth-stage replacement is a useful trade-off only for Tiny and Small models. These measurements let developers of chest radiograph screening tools weigh model size and speed against a quantified loss of diagnostic discrimination.

Comment
10 pages, 4 figures, 9 tables. Submitted to an IEEE journal

Closest papers

Nearest neighbours by meaning across the whole index.

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.67
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31

Rethinking weakly supervised localization on chest radiographs: position nulls, protocol dependence, and PACE

cs.CV cs.LG ·2026-09-29 ·Shixin Qiu
benchmark similarity 0.67
Abstract

Weakly supervised localization on chest radiographs is reported as a single overlap accuracy, and those numbers are not comparable across papers. We measure what one contains. Against position-null controls that keep a readout's own box and move only its position, class activation mapping and its gradient-weighted variant beat the null on two to four of seven annotated findings on ChestX-ray14 and two of eight on CheXlocalize. The null is beatable: three board-certified radiologists clear it on four to seven. Three rarely stated choices each move a result by more than most reported method effects: the results regime, the extraction threshold, and the mask-to-box rule, whose cost is predicted by how fragmented the thresholded mask is. Predicted box area alone reverses a paired comparison. These measurements produced PACE, for \emph{population anomaly and class evidence}, which multiplies the finding identity from the label-trained head by the spatial evidence from a frozen radiograph backbone that never sees a pathology label. It is the case study that made the protocol dependence visible, and we report its costs beside its gain: in an exploratory matched-area analysis it improves strict-overlap accuracy on both corpora and beats a label-derived second map, but it is the least faithful of the three readouts to the classifier's causal map, its advantage depends on the box rule, and, this benchmark releasing no localization validation set, every design choice behind it was made on the boxes it is scored on. Its one clean transfer beats one baseline and loses to the other.

0.27

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.63
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.62
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

cs.CV cs.HCeess.IVeess.SP ·2026-10-30 ·Nattakorn Kittisut, Roy M. Gabriel, Marly van Assen, Mohammadreza Zandehshahvar, Carlo N. De Cecco +2 more
similarity 0.62
Abstract · 20 pages on main manuscripts (3 tables + 4 figures), 14 pages supplementary (10 tables + 8 figures)

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

0.17

Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

cs.CV cs.LG ·2026-09-29 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.62
Abstract

Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even when it depends strongly on how the benchmark was evaluated. We study this problem on the widely used Kermany pediatric chest radiograph dataset using nine image classifiers and a controlled evaluation protocol. Under the same protocol, the eight pretrained backbones differ by only 0.026 AUROC. In contrast, changing whether the backbone is frozen or fine-tuned changes AUROC by 0.044 on average, and changing the decision threshold changes balanced accuracy by 0.090 on average. The official test split is also measurably different from the training pool: a partition classifier distinguishes them at AUC 0.697, rising to 0.898 for normal radiographs. Most strikingly, a classifier using only file properties, with no image anatomy, reaches 0.992 balanced accuracy within the training pool but falls to 0.496 on the official test split. Validation-fitted thresholds and calibration also transfer imperfectly. These results show that a high benchmark score can support different conclusions when the split, training policy, threshold, metric, calibration, and uncertainty are not communicated with it. We end with a seven-item reporting recommendation in which each item is tied to an effect measured in the study

0.11

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.61
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

cs.CV cs.AI ·2026-11-01 ·Bradley J Erickson, Sara Salehi
similarity 0.60
Abstract · 22 pages, 3 tables, 2 figures

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

0.25