CS Paper Radar

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

Nattakorn Kittisut, Roy M. Gabriel, Marly van Assen, Mohammadreza Zandehshahvar, Carlo N. De Cecco, Elizabeth A. Krupinski, Ali Adibi

cs.CV cs.HCeess.IVeess.SP ·submitted 2026-10-30 17:59 UTC · v1

Abstract

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

Comment
20 pages on main manuscripts (3 tables + 4 figures), 14 pages supplementary (10 tables + 8 figures)

Closest papers

Nearest neighbours by meaning across the whole index.

Predicting Radiologist Expertise from 3D Gaze Patterns During CT Interpretation

cs.CV cs.AIcs.LG ·2026-08-24 ·Leila Khaertdinova, Anna Anikina, Claudia Mello-Thoms, Bulat Ibragimov
top venuecode/data similarity 0.69
Abstract · Accepted at MICCAI 2026

Accurate interpretation of volumetric CT requires efficient navigation of 3D image volumes and attention to diagnostically relevant regions. While eye-tracking has been widely studied in 2D medical imaging, its use for expertise assessment in CT settings remains limited. We propose a gaze-informed transformer framework for expertise classification in thoracic CT. Using a DINOv2 backbone, radiologist fixation patterns are integrated into volumetric feature learning through (1) a learnable log-space bias in self-attention and (2) gaze-weighted pooling of patch embeddings. We trained and evaluated our approach on 182 CT reading sessions from five radiologists with varying levels of experience. On a held-out test set, the model achieves an ROC-AUC of 0.91 and F1 score of 0.86, outperforming adapted methods. These findings suggest that incorporating visual search behavior into transformers may support objective, process-based expertise assessment in radiology. Code is available via https://github.com/leiluk1/GazeToSkill.

0.49

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

cs.CV cs.LG ·2026-09-18 ·Mushir Akhtar, M. Tanveer, Mohd. Arshad
benchmark similarity 0.66
Abstract · 27 pages, 7 figures, and 21 tables; includes extended methods, statistical analyses, and robustness evaluations

A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.

0.28

RadAI: Gaze-Intention Fusion Pipeline for Attention-Guided Educational Videos in Chest X-Ray Interpretation

cs.CV ·2026-10-24 ·Kavish Mehta, Yuvan Siddharth Katamaneni, Akash Awasthi
publishedhot direction similarity 0.65
Abstract · 5 pages, 2 figures, 1 table, accepted to 2026 MIT IEEE URTC conference

Chest radiograph interpretation errors often arise from failures in visual search: although trainees may correctly identify an abnormality once pointed out, they frequently fail to fixate on the relevant region, while expert search strategies (where radiologists look, in what sequence, and for how long) remain largely implicit. Eye movement modeling examples (EMME), which replay a recorded expert's gaze over the image, have been shown to improve novice detection of findings on chest radiographs, but producing one requires an eye-tracking session on that specific case, so teaching sets are limited to recorded sessions by experts. In this work, RadAI is presented, the first end-to-end framework for transforming predicted radiologist gaze into narrated instructional videos, enabling scalable gaze-guided training without collecting new eye-tracking data. Given only a chest X-ray and its report, RadAI predicts an expert fixation sequence, associates each interval of that sequence with the diagnostic finding it pursues, extracts the corresponding image region, and renders the result as an EMME-style video in which each highlighted finding is narrated with synthesized speech. RadAI is evaluated on 97 cases from the EGD-CXR dataset, assessing whether the highlighted regions correspond to annotated abnormality locations. We position this work as a framework for scalable generation of educational content for residents and medical students in the field of radiology.

0.34

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.64
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31

APED-CXR: Adaptive Privileged Evidence Distillation for Chest X-Ray Grounding with Image-Only Inference

cs.CV ·2026-10-21 ·Md Shihabul Islam Shovo, Nishi Kanta Paul, Jamil Fayyad
similarity 0.63
Abstract · 5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

Compact chest X-ray (CXR) models that localize findings suit deployment, but box annotations are limited and report-aware multimodal models are expensive at inference. We introduce APED-CXR, which distills report-informed spatial evidence from a frozen multimodal teacher into a student with 11.1M parameters that predicts diseases and boxes from shared evidence maps and requires the image alone at test time. During training, the teacher uses the radiograph, report, and queried class to evaluate regions proposed from the student's current evidence maps, and its support scores serve as training targets for the student's pooled evidence scores within these regions. Trained on PadChest and evaluated on held-out PadChest-GR, refreshing the student's proposals for teacher evaluation improves box-level localization F1 from 0.302 with fixed warm-up proposals to 0.338 (IoU >= 0.5; gain 0.036, 95% CI [0.022, 0.049]), while maintaining diagnostic AUC. This gain depends on the teacher checking current proposals: with equally many random boxes, a fixed dense box set, teacher-generated boxes, or report rules instead of the teacher, F1 stays near the fixed-proposal level, and proposals two refreshes old recover only part of the gain. On NIH ChestX-ray14, a secondary test set, box recall also rises from 0.423 to 0.447.

0.30

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.63
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.62
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.21

MC-CXR: A Multi-Context Chest X-ray Benchmark for Context-Induced Disruption in Vision-Language Models

cs.CL ·2026-08-25 ·Junhyeok Lee, Songsoo Kim, Kyu Sung Choi
top venuebenchmarkcode/data similarity 0.62
Abstract · 15 pages, 3 figures, 4 tables. Accepted to Findings of EMNLP 2026

Vision-language models (VLMs) are increasingly used in clinical pipelines where a chest X-ray is interpreted alongside retrieved reports, preliminary notes, or prior imaging. Existing benchmarks measure whether models answer correctly in isolation, but not whether they preserve a correct image-only decision when plausible context conflicts with the image. We introduce Multi-Context Chest X-ray (MC-CXR), a benchmark of 240 cases expanded into 2,522 instances that isolates context-induced disruption through paired perturbation. Each case fixes the current image and target finding while presenting matched reliable and misleading context across text and prior CXR, with visual overlays where available. MC-CXR defines three task families and two paired metrics, the switch-to-wrong rate and the context-aligned error rate. We evaluate ten VLMs spanning open-source general, medical-domain, and closed-source systems. Image-only accuracy is necessary but insufficient. Mean switch rates range from 45.6-78.1% across misleading textual sources and 35.7-61.7% across misleading visual sources. Among switched predictions, 74.6% align with the misleading label for text versus 17.6% for visual context, a 57.0-point gap (95% CI 50.9-62.8). This text-visual asymmetry is observed under the standardized direct-answer protocol. The dataset is available on PhysioNet.

0.59